User manual OMRON F3SP-U3P-TGR

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON F3SP-U3P-TGR. We hope that this OMRON F3SP-U3P-TGR user guide will be useful to you.


OMRON F3SP-U3P-TGR : Download the complete user guide (663 Ko)

You may also download the following manuals related to this product:

   OMRON F3SP-U3P-TGR (640 ko)
   OMRON F3SP-U3P-TGR (585 ko)
   OMRON F3SP-U3P-TGR (587 ko)
   OMRON F3SP-U3P-TGR (1872 ko)
   OMRON F3SP-U3P-TGR (548 ko)
   OMRON F3SP-U3P-TGR DATASHEET (669 ko)
   OMRON F3SP-U3P-TGR DATASHEET (584 ko)
   OMRON F3SP-U3P-TGR DATASHEET (678 ko)
   OMRON F3SP-U3P-TGR DATASHEET (775 ko)
   OMRON F3SP-U3P-TGR DATASHEET (758 ko)
   OMRON F3SP-U3P-TGR DATASHEET (663 ko)
   OMRON F3SP-U3P-TGR DATASHEET (760 ko)
   OMRON F3SP-U3P-TGR DATASHEET (884 ko)

Manual abstract: user guide OMRON F3SP-U3P-TGR

Detailed instructions for use are in the User's Guide.

[. . . ] E04E-EN-01 F3SP-U3P-TGR Series Single Beam Safety Control Unit Safety Level 2 USER´S MANUAL F3SP-U3P-TGR Cat. E04E-EN-01 User's manual F3SP-U3P-TGR series Single beam safety control unit, safety level 2, from 1 to 2 pairs of photocells E3FS USER'S MANUAL 1 F3SP-U3P-TGR User's manual The device conforms with the EC requirements in compliance with the following standards: -Low Voltage Directive 73/23/EEC -EMC Directive 89/336/EEC -Machinery Directive 89/392/EEC -IEC 61496-1: 1997 -IEC 61496-2 ed. 2 IEC 2001 (CDV draft 8) -DIN V VDE 0801: 1990 and -amendment A1: 1994 -EN 61000-4-2, -3, -4, -5, -6 -EN 55022: 1994 -DIN EN 60204-1: 1993 -EN 50178: 1998 -IEC 664-1: 1997 MANUFACTURER: TECHNO-GR s. r. l. +39 011 9452041 FAX +39 011 9452090 USER MANUAL: Version 3. 0 of 12/06/2003 3 F3SP-U3P-TGR User's manual INDEX 1 BEFORE USING THE DEVICE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 1-1 1-2 1-3 GENERAL INSTRUCTIONS. [. . . ] Do not install the safety PES in a location affected by shiny surface reflections. 10 F3SP-U3P-TGR User's manual 5 5-1 CONNECTIONS. REFERENCES ON THE TERMINAL BOARD. TERMINAL BLOCK ASSIGNMENT TERMIN AL 1-2 3 4 5 6 7 8 9 10 11 12 13 - 14 15 - 16 OUTER CONNECTION Connect to the 24 Vdc power supply, 1 to 24Vcc and 2 to 0Vcc Connect the muting signaller LMS. contact. 11 F3SP-U3P-TGR 5-2 PIN OVERVIEW User's manual 12 F3SP-U3P-TGR 5-3 WIRING EXAMPLE. User's manual Connection of 2 safety PES to the control unit. GND MAIN SUPPLY 24 V DC Muting A-B TOP VIEW T E S T N. Align the photocells by observing the LEDs on the control unit: If the alignment of the relevant pair of photocell is correct, the corresponding LED will turn on. After the alignment, turn off the power supplying the control unit, close the TEST pushbutton and re-power the control unit again. At the end of this operation, the unit indicates the right alignment with the guard led green on. Carry out all the checks described in the final checks and in the routine maintenance operations. During aligning operations or normal working, check that the photocells connected to the same or other units do not interfere which each other, modifying their mutual position, for instance by positioning some pairs of transmitters on the other receiver side. NOTICE The control unit can detect the mutual interference between safety PESs. The control unit forces the output contact to open, when it detects external disturbance light including mutual interference light. The safety PESs should be installed the following way to avoid mutual interference. - Emitters and receivers of safety PES are installed alternately as follows: TX RX RX TX 15 F3SP-U3P-TGR User's manual 7 OPERATING PROCEDURES. 7-1 DIP-SWITCHES CONFIGURATION. The configuration indicated in the table must be selected on the dip-switch available in the front. 4 X 3 Off On not used Function muting A-B act on the sensor couples 1 and 2. Function muting 60 s muting s * Function manual restoring automatic restoring ON Function SW 1 4 3 2 1 2 Off On 1 Off On The control-unit is manufactured from the factory with the following configuration: · Automatic reset, all 2 sensors in muting, the maximum duration of the muting is of sixty seconds. * infinite muting duration: this feature must be used carefully because it's against the norm. Using this, the user must know that it works under its sole responsibility. In case you use only a pair of photocells, operate as follows: Turn off the power and short the terminal 11-12. At least one pair of photocells must be connected, otherwise the control unit is locked. 16 F3SP-U3P-TGR 7-3 MUTING FUNCTION. User's manual 7. 3. 1 DESCRIPTION. As mentioned in the introduction, the muting function can be enabled with any unit by simply connecting the F39-A11 muting lamp when the unit is switched off. This presence of this indicator is recognised every time the unit is powered on. If its presence is detected, the unit will enable the muting function and if its presence is not detected the unit will ignore any request for muting. It is important to note that if the muting indicator is connected during the F3SP-U3P-TGR is powered on, it will not be recognised and the muting function will not be enabled. Once enabled, if the indicator develops a fault or is removed without first disconnecting the unit's power supply, it will signal an error as described in section 8. [. . . ] · GREEN LED STATUS: if switched on, all the unit test are correctly passed, if blinking an error occurred. · RED LED BREAK : if switched on, the unit has detected an object or an error has occurred - which can be possibly recovered by pressing the reset button -; in this condition, the safety outputs are opened. · GREEN LED GUARD: if switched on, in green, the barrier is working regularly and there are no detected obstacles; in this condition, the safety outputs are closed. The F3SP-U3P-TGR has inside an easy diagnosis with the four green leds to detect the most common errors or failure that can be presents: · One led flashing: Probable error in a photocells pair. · Two leds flashing: Probable incorrect setting of numbers of beams connected. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON F3SP-U3P-TGR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON F3SP-U3P-TGR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.