User manual OMRON E3X-DA-S

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON E3X-DA-S. We hope that this OMRON E3X-DA-S user guide will be useful to you.


OMRON E3X-DA-S : Download the complete user guide (1247 Ko)

You may also download the following manuals related to this product:

   OMRON E3X-DA-S (155 ko)
   OMRON E3X-DA-S (546 ko)
   OMRON E3X-DA-S (158 ko)
   OMRON E3X-DA-S (161 ko)
   OMRON E3X-DA-S DATASHEET (5116 ko)
   OMRON E3X-DA-S DATASHEET (472 ko)
   OMRON E3X-DA-S DATASHEET 2 (572 ko)

Manual abstract: user guide OMRON E3X-DA-S

Detailed instructions for use are in the User's Guide.

[. . . ] of conductors 3 4 Model E3X-CN11 E3X-CN21 Sensor I/O Connectors (Order separately) Size Cable type Shape Cable length 2m 5m 4 conductors 2m 5m Model XS3F-M421-402-A XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A Straight connector M8 Standard cable L-shaped connector Mobile Console (Order Separately) Shape Model Remarks Mobile Console with head, cable, and AC adapter provided as accessories. Power supply provided by chargeable battery (Set form) E3X-MC11 E3X-MC11-C1 Mobile Console E3X-MC11-H1 Head E39-Z12-1 Cable (1. 5 m) In general, amplifier units and connectors are sold separately. Refer to the following tables for order placement. amplifier units Type Standard models NPN PNP E3X-DA8 E3X-DAB8 E3X-DAG8 E3X-DAH8 --E3X-DA9 E3X-DA8TW E3X-CN21 E3X-CN22 Applicable Connector (order separately) Master Slave connector connector E3X-DA6 E3X-DAB6 Mark-detecting models E3X-DAG6 Infrared models E3X-DAH6 Differential E3X-DA6D output Monitor-output models E3X-DA7 Twin-output models E3X-DA6TW + E3X-CN11 E3X-CN12 When using 5 sets amplifier units (5 Units) + 1 Master Connector + 4 Slave Connectors A-422 Advanced Photoelectric Sensors Rating/Performance Amplifier units Prewired Type Model NPN output PNP output Standard models E3X-DA11-N E3X-DA41-N Monitor-output models Mark-detecting models Infrared models Water-resistant models E3X-DA11V E3X-DA41V Twin-output models E3X-DA11TW E3X-DA41TW E3X-DA-S E3X-DA21-N E3X-DAB11-N E3X-DAG11-N E3X-DAH11-N E3X-DA51-N E3X-DAB41-N E3X-DAG41-N E3X-DAH41-N Blue LED (470 nm) Green LED (525 nm) Infrared LED (870 nm) Item Light source (wave length) Red LED (660 nm) Red LED (660 nm) Power supply voltage Power consumption 12 to 24 VDC ±10%, ripple (p-p) : 10% max. at supply voltage 24 V) Digital display OFF: Power consumption 600 mW max. [. . . ] (0. 01 mm dia. ) (0. 3 mm dia. )*3 (0. 2 mm dia. ) Standard object (mm) *1 Minimum sensing object *2 (Opaque object) default 0. 5 or 1 ms 280 (1960) 60 690 450 0. 5 or 1 ms 180(1260) 40 450 290 *1. The value can be detected if the temperature varies within the operating ambient temperature. The digital value is 1000 and the value can be detected in each detection area. Refer to the E3X-DA-S for the note of the fiber unit. (Reflective model) Sensing distance (mm)*1 Sensitivity switching 11 steps can be set Fiber type Response time 1 270 or 570 s 80 13 HIGH 2 3-11 1 to 200 ms or 2 to 400 ms 120 20 1 270 or 570 s 45 7 LOW 2 3-11 1 to 200 ms or 2 to 400 ms 80 13 150 x 150 (0. 01 mm dia. ) 25 x 25 (0. 01 mm dia. ) Standard object (mm) *2 Minimum sensing object *3 (Opaque object) default 0. 5 or 1 ms 0. 5 or 1 ms E32-ED11R E32-ED21R 90 15 60 10 *1. The value can be detected if the temperature varies within the operating ambient temperature. (Value when the sensing object is operating) Note: Refer to E3X-DA-S for the note of the fiber unit. E3X-DA-S A-425 Differences from E3X-DA-S amplifier unit Differential output type (edge detection type) Item Item NPN output Power consumption Control ON/OFF output output Detection mode Response time Timer function APC Func Zero reset tions Initial reset Sensitivity switching Teaching level Indicator lamp Prewiring type E3X-DA11D amplifier units with Connectors E3X-DA6D Power consumption 960 mW max. (at power supply voltage 24 V, power consumption 40 mA max. ) Load current 50 mA (residual voltage NPN/PNP: 1 V max. L ON The range between the CH1 and CH2 thresholds turns ON D ON The range between the CH1 and CH2 thresholds turns OFF (CH2 is always OFF) E3X-DA-S A-427 PNP output Model Output transistor Status Timing chart Incident light No incident light T ON Operation Indicator OFF (orange) ON Output transistor OFF Operate Load (relay) Release (Between blue and black) Incident light No incident light T Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (relay) Release (Between blue and black) Incident light No incident light T Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (relay) Release (Between blue and black) Incident light No incident light T Operation ON Indicator OFF (orange) ON Output transistor OFF Operate Load (relay) Release (Between blue and black) CH1/ Incident light CH2 No incident light Operation Indicator (orange) Output transistor Operation Indicator (orange) Brown Mode selection switch Output circuit E3X-DA41-N E3X-DAB41-N E3X-DAG41-N E3X-DAH41-N E3X-DA41V E3X-DA8 E3X-DAB8 E3X-DAG8 E3X-DAH8 E3X-DA44V Light ON L ON (LIGHT ON) 1 Display Main circuit Black Control output Load 3 4 12 to 24 VDC Blue Dark ON D ON (DARK ON) Connector Pin Arrangement 1 2 4 3 Note: Pin 2 is not used. Light ON L ON (LIGHT ON) Display Operation Indicator (orange) Brown E3X-DA51-N E3X-DA9 Main circuit 47W Black Control output Monitor output Load 1 to 5 V (see note) Orange Load Blue 12 to 24 VDC Dark ON D ON (DARK ON) Note: Load resistance: 10kWmin. Light ON E3X-DA41TW E3X-DA8TW T ON OFF ON OFF Operate Load (relay) Release (Between blue and black) CH1/ ncident light CH2 No incident light Operation Indicator (orange) Output transistor ON OFF ON OFF L ON (LIGHT ON) Operation Indicator (orange) Display Operation Indicator (orange) Brown Control output 1 Black Control output 2 Orange Load Main circuit 12 to 24 VDC Load T Dark ON D ON (DARK ON) Blue Operate Load (relay) Release (Between blue and black) Note: With E3X-DA#TW models, only channel 1 is output when set for area sensing operation. L ON The range between the CH1 and CH2 thresholds turns ON D ON The range between the CH1 and CH2 thresholds turns OFF (CH2 is always OFF) Connectors (Sensor I/O Connectors) Color of cable conductors Brown White Blue Black XS3F-M421-402A XS3F-M421-405A XS3F-M422-402A XS3F-M422-405A Class 4 3 2 1 1 2 3 4 Wire, outer jacket color Brown Connector pin No. A B C D Application Power supply (+V) Power supply (0 V) Output For DC White Blue Black Note: Pin 2 is open. A-428 Advanced Photoelectric Sensors Characteristic data (default) Hysteresis vs. sensing distance Reflective model E32-D11L Hysteresis (mm) 30 25 20 15 10 5 0 Superhigh-speed Superlong-distance 100 200 300 400 500 Sensing object: White paper Distance Hysteresis Repeat accuracy (mm) 100 Sensing object: White paper 90 X 80 70 60 50 40 30 20 10 0 20 40 60 ON ON OFF Standard Superhighspeed Standard Superlong-distance 80 100 Distance (mm) Distance (mm) Monitor output vs. In that case, low the sensitivity (raise the threshold) to stabilize detection. EEPROM Write Error If a write error occurs (operation indicator starts flashing) due to power-off, static electricity or other noise in the teaching mode, perform teaching again. Optical communication When connecting the amplifier units, assemble them in close contact. Hysteresis adjustment The Mobile Console allows hysteresis adjustment, but note that the unit may not operate properly if the hysteresis setting is lower than the factory value. 2. Slide one unit toward the other, match the clips at the front ends, and then bring them together until they "click". Clip Click into place (Removing) Slide one unit away from the other and remove them one by one. (Do not remove the connected units together from the DIN rail. ) Note:1 . When the amplifier units are connected to each other, the operable ambient temperature changes depending on the number of connected amplifier units. 2 . Before connecting or removing the units, always switch power off. Fitting of Mobile Console head When fitting the Mobile Console head, a 20 mm or more clearance is needed on the left side. 20mm Use of Mobile Console For the twin output type (E3X-DA##TW), up to 16 channels (eight E3X-DA##TW units) can be set from the Mobile Console E3X-MC11. (Note that the operation mode and area detection cannot be set. ) A-434 Advanced Photoelectric Sensors Amplifier Unit Connectors Installation Connector installation 1. Insert the Master or Slave Connector into the amplifier unit until it clicks into place. Insert Clip 2. Link amplifier units to each other after the master and slave Connectors have been inserted. Apply the supplied seal to the non-connecting surface of the master/slave connector. The sensor bottom is also equipped with a clip removing mechanism. [. . . ] 4-dia. , 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0. 2 mm²; insulation diameter: 1. 1 mm is used. A-436 Advanced Photoelectric Sensors *2 3 Two, 2. 4 dia. 10 Operation Indicator 64. 3 38. 6 5. 3 Mounting Holes 8 31. 5 9. 9 10. 7 3. 4 22. 4 13 Two, 3. 2 dia. A 4-dia. , 4-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0. 2 mm²; insulation diameter: 1. 1 mm) is used. 16 34. 8 Hole for optical communications 2-M3 10. 75 16 2. 4 4 Mounting Bracket (E39-L143)SUS304 stainless steel, sold separately 22. 4 16 Connector type E3X-DA6E3X-DAG6 E3X-DA7E3X-DAH6 E3X-DA8E3X-DAB8 E3X-DA9E3X-DAG8 E3X-DAB6E3X-DAH8 E3X-DA6D 10 Incident level display Threshold level display Operation Indicator 13. 05 17. 15 3 Two, 2. 4 dia. 4. 9 x 3 = 14. 7 64. 3 8 9. 9 10. 7 3. 4 1. 8 13 5. 1 3. 9 1. 7 4. 2 1. 8 38. 6 36. 7 31. 5 14 5. 5 Hole for optical communications 6. 2 1. 7 Dimensions with Master Connector Connected 71 67. 5 64. 3 E3X-CN11: 4. 0 dia. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3X-DA-S




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3X-DA-S will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.