Manual abstract: user guide OMRON E3X-DA-NDATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] While teaching had to be performed for each Amplifier separately, it can now be performed for several Amplifiers at once using the Mobile Console.
Group teaching
Differences in incident light avoided by group zero-reset. The incident levels of several amplifiers can be batchreset to zero by the group zero-reset. This feature is useful for reducing differences between the amplifiers.
Incident level and threshold can be displayed simultaneously.
New Concept
Patent pending
Function indicator Channel settings Incident level monitor Threshold display
Sensor head flashing during Amplifier operation Alternatively, the amplifier channel can be displayed. If the amplifier being operated is away from the sensor head, the sensor head can be flashed or the amplifier channel can be displayed.
5ch 4ch 3ch 2ch 1ch
Operation keys
Battery monitor Head Optical communications
A-420
Advanced Photoelectric Sensors
Ordering Information
Amplifier units
Prewired
Item Standard models Monitor-output models Mark-detecting models (Blue LED) Mark-detecting models (Green LED) Infrared models Differential output type Shape Control output ON/OFF output ·ON/OFF output ·Monitor output Model NPN output E3X-DA11-N E3X-DA21-N E3X-DAB11-N E3X-DAG11-N E3X-DAH11-N E3X-DA11D PNP output E3X-DA41-N E3X-DA51-N E3X-DAB41-N E3X-DAG41-N E3X-DAH41-N --E3X-DA-N
Water-resistant models
ON/OFF output
E3X-DA11V
E3X-DA41V
Twin-output models
E3X-DA11TW
E3X-DA41TW
Connector type
Item Shape Applicable Connector (order separately) Master Standard models Slave Master Monitor-output models Slave Mark-detecting models (Blue LED) Mark-detecting models (Green LED) Infrared models Slave Differential output type Master Slave E3X-CN12 E3X-CN11 E3X-CN12 E3X-DA6D ON/OFF output --Master Slave Master Slave Master E3X-CN22 E3X-CN11 E3X-DAB6 E3X-CN12 E3X-CN11 E3X-DAG6 E3X-CN12 E3X-CN11 E3X-DAH6 E3X-DAH8 E3X-DAG8 E3X-DAB8 E3X-CN12 E3X-CN21 E3X-CN11 ON/OFF output E3X-DA6 E3X-DA8 Control output Model NPN output PNP output
·ON/OFF output ·Monitor-output
E3X-DA7
E3X-DA9
Water-resistant models (M8 Connector)
XS3F-M421-40#-A XS3F-M422-40#-A
E3X-DA14V
E3X-DA44V
Master Twin-output models Slave
E3X-CN21 E3X-DA6TW E3X-CN22 E3X-DA8TW
E3X-DA-N
A-421
Amplifier units Connectors (Order Separately) Note: Stickers for Connectors are included as accessories.
Item Master connector 2m Slave connector 1 2 E3X-CN12 E3X-CN22 Shape Cable length No. [. . . ] Use to select SET, ADJ, or RUN mode.
Operation Indicator (orange) Channel-selection Switc ON when output is ON. Mode Selector Use to select SET, ADJ, or RUN mode.
E3X-DA-N
A-429
E3X-DA-N
Repeated accuracy vs. sensing distance Reflective model E32-DC200
Operation
General
1 Changing the Display (RUN Mode) 2 Zero-reset (RUN Mode)
Set the mode selector to RUN .
RUN
Digital incident level (4000 max. )
Set the mode selector to RUN .
RUN
Digital incident level (4000 max. )
(Factory-set to RUN)
TEACH MODE
2s
* To reset to zero again:
TEACH
1s
1s
Digital Percent
To return the initial digital incident level:
TEACH MODE
Hold down both for 3 s.
Note: There is no limit on the number of times zero-reset can be used.
MODE
2s
Analog incident level and threshold
3
Initial Reset (SET Mode)
Set the mode selector to SET .
SET
MODE
2s
TEACH
MODE
@ Manual Tuning (Fine Sensitivity Adjustment) in ADJ Mode Perform fine sensitivity adjustment after teaching and manual tuning (without using the teaching function) in the way shown below:
Twin-output Models
Select the channel to be adjusted using the channel selection switch.
CH1 CH2
Hold down both for 5 s.
TEACH
MODE
MODE
Cancel Fine sensitivity adjustment
TEACH MODE
Execute initial reset
Set the mode selector to ADJ .
ADJ
Sensitivity increment with threshold decrement
Sensitivity decrement with threshold increment
The items displayed in ADJ mode vary with the display setting in RUN mode.
RUN mode Digital incident level Digital percent Analog value ADJ mode Digital threshold Digital Percent Analog value
A-430
Advanced Photoelectric Sensors
4
Setting Functions in SET Mode
Set the mode selector to SET .
SET
TEACH
Digital incident level display
There are four different sensitivity settings. Refer to page AB- for details.
MODE
2s
Sensing function
Displayed as "F".
Monitor Focus
Standard (factory-set)
TEACH
Available with: E3X-DA21-N E3X-DA51-N E3X-DA7 E3X-DA9
(B)
Super-long distance
TEACH
(A)
MODE
2s
Super-high speed
TEACH MODE
Setting upper Alternates between limit for monitoring "A-UP" and setting value.
(Factory setting)
Alternates
2s
Timer function 0 (Factory-set)
Displayed as "t".
TEACH
In units of 100 from 4, 000
Alternates
TEACH
Adjustable in 1-ms units for 0 to 20 ms and in 5-ms units for higher.
TEACH
200
TEACH
Alternates
MODE
2s
Flashing setting OFF (factory-set)
Displayed as "L".
TEACH
Alternates
TEACH
TEACH
ON
TEACH MODE MODE
Note: It is not possible to set an upper limit that is lower than the lower limit.
2s
Hold setting OFF (factory-set)
Displayed as "H".
Setting lower Alternates between limit for monitoring "A-LO" and setting value.
(Factory setting)
TEACH
Alternates
TEACH
Peak
TEACH
In units of 100 from 0
Alternates
Bottom
TEACH MODE
TEACH
Alternates
2s
Display orientation setting
Reversing display
TEACH
Standard (factory-set)
TEACH TEACH
Alternates
Reverse
(B)
(A)
TEACH
Note: It is not possible to set an lower limit that is lower than the upper limit.
E3X-DA-N
A-431
E3X-DA-N
Twin-output models
4 Setting Functions in SET Mode
Set the mode selector to SET .
SET
TEACH
Digital incident level display
There are four different sensitivity settings. Refer to page AB- for details.
(B)
Setting the operating mode Changing the operating mode
(A)
The operating mode for the channel set with the channel-selection switch can be changed.
Changed using the channel-selection switch
CH1 CH2
MODE
2s
Timer function 0 (Factory-set)
Displayed as "t".
Channel 1
Channel 2
TEACH
Adjustable in 1-ms units for 0 to 20 ms and in 5-ms units for higher.
L ON
(Factory setting)
TEACH
L ON
(Factory setting)
TEACH MODE
200
TEACH
2s
D ON
D ON
Flashing setting OFF (Factory-set)
Displayed as "L".
MODE
2s
Sensing function
Displayed as "F". ON
TEACH
Standard (factory-set)
TEACH MODE
TEACH
2s
Hold setting OFF (Factory-set)
Displayed as "H".
Super-long distance
TEACH
TEACH
Super-high speed
TEACH
Peak
TEACH
Area
TEACH
(B)
(A)
MODE
Bottom
TEACH
@ Area Sensing Area sensing is possible using the threshold values for channels 1 and 2. · If channel 1 is set to L/ON, output turns ON when the incident level is between the thresholds. · If channel 1 is set to D/ON, output turns OFF when the incident level is between the thresholds. (Control output 2 is always OFF. )
2s
Display orientation setting
Reversing display
Standard (Factory-set)
TEACH
Reverse
TEACH
A-432
Advanced Photoelectric Sensors
General
E3X-DA-N
When teaching is performed (SET mode)
· The four types of teaching given below are available. · Once setting is made, operation is performed in the preset status thereafter. Restart setting from the beginning.
Twin-output models only Select the channel to be adjusted using the channel selection switch. CH1
Set the mode selector to
SET
CH2
.
SET
Maximum Sensitivity Setting
Procedure
Two-point With/Without-object Teaching
Operation
Procedure
SET
Operation Set the mode selector to SET.
SET
1 2
Set the mode selector to SET. Set to RUN mode.
1
TEACH
3s
(red)
2
With the work present, press the SET button once (about 1 s).
Object
3
TEACH
1s
(green)
3
The level indicators are lit red.
(red)
4
RUN
One-point without-object teaching
Procedure
Operation Set the mode selector to SET.
SET
4
If no work is pending, press the SET button once (about 1 s).
TEACH
1
1s
5 2 Press the SET button once (about 1 s).
TEACH
6
1s
Setting is completed when the green indicators are turned ON. Set to RUN mode.
(green)
RUN
Note: With and without work may be in any order.
3
Setting is completed when the red level indicators are turned ON. Set to RUN mode.
RUN
Pin-point teaching (for positioning)
(red)
Procedure
Operation Set the mode selector to SET.
SET
1
4
2 5 The threshold is automatically set with the object.
Output Object
If no work is pending, press the SET button once (about 1 s).
TEACH
1s
ON
3
The level indicators are lit red.
(red)
Note: If one-point teaching is not available because the difference in level is too fine, try two-point teaching.
Operation Mode Selector
Operating mode Light ON Dark ON L ON D ON
L
4 Operation
(Factory-set)
D
Place the object in the desired position, and press the TEACH button for 3 seconds min.
Object
TEACH
3s
There is no operation mode selector for twin-output models.
5
Setting is completed when the green indicators are turned ON. (Red indicators start flashing if setting is not OK. ) Set to RUN mode.
RUN
(green)
6
E3X-DA-N
A-433
Precautions
Correct Use Amplifier units
Design Power ON The sensor is ready to sense an object within 200 ms after turning the power ON. If the load and sensor are connected to different power supplies, always turn on the sensor power first. Adjustment Mutual interference prevention function The digital display value may vary due to the light from the other sensor. In that case, low the sensitivity (raise the threshold) to stabilize detection. EEPROM Write Error If a write error occurs (operation indicator starts flashing) due to power-off, static electricity or other noise in the teaching mode, perform teaching again. [. . . ] 31. 5 1. 5
Dimensions with Slave Connector Connected
71 67. 5 64. 3
E3X-CN12: 2. 6 dia. 31. 5 1. 5 17. 45 11. 55
12. 95
12. 95
1. 8 5. 1 3. 9
4 10
1. 8 5. 1 3. 9
3
4. 8
4 10
E3X-DA-N
A-437
E3X-DA-N
Amplifier units with Cables, Twin-output Models E3X-DA11TW E3X-DA41TW
With Mounting Blanket Attached
17. 15 13. 05 4. 9 x 3 = 14. 7 Incident level display Threshold level display (A) * 1
Amplifier Units M8 Connectors, Water-resistant Models E3X-DA14V * The Mounting Bracket can also be on side A. E3X-DA44V
With Mounting Bracket Attached
30. 05 25. 95 4. 9 x 3 = 14. 7 Incident level display Threshold level display
Operation Indicator 81. 5 Two, 2. 4 dia. 12 6. 9 40
(A) * 1
2. 8 M8 8 33 9. 9 10. 7 11. 2
3. 9
3. 4
4. 3 11. 5
23. 9 14. 4
16 37 67. 2 16 3. 4 5. 4
Hole for optical communications
11
23. 9 Two, M3
Mounting Bracket (E39-L148), Sold separately SUS304 stainless steel
16 5. 4 3. 4
Amplifier units with Standard Connectors, Twin-output Models E3X-DA6TW E3X-DA8TW
Threshold level display Operation Indicator Incident level display
13. 05 17. 15 10 3 Two, 2. 4 dia.
4. 9 x 3 = 14. 7 64. 3
8 9. 9 10. 7 3. 4 1. 8 13 5. 1 3. 9 1. 7 4. 2 1. 8 38. 6 36. 7 Hole for optical communications
31. 5 14
5. 5
6. 2
1. 7
Dimensions with Master Connector Connected
71 67. 5 64. 3
Dimensions with Slave Connector Connected
71 67. 5 64. 3
E3X-CN21: 4. 0 dia. [. . . ]