User manual OMRON E3MC DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON E3MC. We hope that this OMRON E3MC user guide will be useful to you.


OMRON E3MC DATASHEET: Download the complete user guide (1603 Ko)

You may also download the following manuals related to this product:

   OMRON E3MC DATASHEET (1046 ko)
   OMRON E3MC DATASHEET (2015 ko)
   OMRON E3MC DATASHEET (1720 ko)
   OMRON E3MC DATASHEET (1859 ko)
   OMRON E3MC DATASHEET (604 ko)
   OMRON E3MC DATASHEET (843 ko)
   OMRON E3MC DATASHEET (623 ko)
   OMRON E3MC DATASHEET (1776 ko)
   OMRON E3MC DATASHEET (172 ko)
   OMRON E3MC DATASHEET (462 ko)

Manual abstract: user guide OMRON E3MCDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Color sensor (LED type) E3MC E3MC RGB Color Sensor Discriminates Delicate Differences in Color. Features Double Indication ensuring high visibilty. · Conformity with the registered colors can be monitored at eight levels. (Detection level indicators) · Allows fine adjustment between fine or rough discrimination while monitoring the measured results. · Wide temperature range from -20°C to 55°C and excellent detection stability. Maintenance-free LED Light Source Incorporates RGB LED light sources with a long service life more than several tens of thousand hours. Great maintenance-cost saver ensuring high performance (Halogen lamps used as light sources must be replaced or readjusted every nine months or so. ) Stable and Powerful Detection for Inline Use Stable detection is assured with a threshold of ±10 mm for built-in amplifier type and ±4 mm for optical fiber type. [. . . ] (For conformity output setting) Set the threshold to a higher level for highly-precise color discrimination or to a lower level to allow margins for discriminated colors (ignore minor tint differences, dirt retention or like). Detection Level Tolerance Operation indicator: ON Control output: ON Operation indicator: OFF Control output: OFF Threshold value Threshold value Detection level 1 2 3 BANK 4 LEVEL THRESHOLD TEACH SELECT TEACH ADJ RUN Make measurement in the RUN mode. The registered color can be selected with bank selection input. A-154 Standard Photoelectric Sensors 4 output Models (E3MC-MA##/E3MC-MX##/E3MC-MY##) 1. Channel Selection OUTPUT 1 2 CH- 3 OUT 4 LEVEL THRESHOLD BLIP (2) TEACH (1)SELECT ADJ RUN TEACH (1) Set the Mode Selector to the ing the SELECT button. TEACH mode and then select the channel usOK OUTPUT 2. Color Registration OUTPUT OUTPUT 1 2 3 BANK 4 LEVEL THRESHOLD Sensor Sensor 1 2 CH- 3 CHOUT 4 OUT 1 2 3 LEVEL 4 LEVEL THRESHOLD THRESHOLD BLIP BLIP If color registration has not been completed, all Not red threshold indicators Good (red) flicker. TEACH SELECT TEACH ADJ RUN TEACH TEACH SELECT SELECT Registered object Registered object TEACH TEACH ADJ ADJ RUN RUN All detection level indicators (green) turn ON. The threshold is set to 4. Locate the registered object at the detection point and press the TEACH button. 3. Threshold Adjustment (If Required) OUTPUT Sensor 1 2 CH- 3 OUT 4 LEVEL THRESHOLD BLIP TEACH SELECT Detection Level and Tolerance As the detected color becomes closer to the registered color (similar colors), the number of lit detection level indicators (green) increase. The control output will turn ON if the detection level (green) exceeds the threshold level (red) and turn OFF if the detection level does not exceed the threshold level. (For conformity output setting) Set the threshold to a higher level for highly-precise color discrimination or to a lower level to allow margins for discriminated colors (ignore minor tint differences, dirt retention or like). Detection Level Sensing object TEACH ADJ RUN ADJ Tolerance Operation indicator: ON Control output: ON Operation indicator: OFF Control output: OFF (Adjustment can be made without a sensing object) The bank selected in the ADJ mode or TEACH mode will become the bank for the RUN mode. Threshold value Threshold value Detection level E3MC A-155 E3MC peration OUTPUT For indicating detection level and threshold value for other channels LEVEL THRESHOLD 1 2 CH- 3 OUT 4 Press the SELECT button. For checking which channel is indicated OUTPUT OUTPUT TEACH SELECT TEACH ADJ RUN 1 2 CH- 3 OUT 4 LEVEL THRESHOLD BLIP 1 2 CH- 3 OUT 4 LEVEL THRESHOLD BLIP Detection is made in the RUN mode. The output ON/OFF status of each channel is displayed on the channel indicators. Double-displayed channels can be checked and selected by pressing the button. TEACH SELECT TEACH SELECT Press the TEACH button TEACH ADJ RUN TEACH ADJ RUN Displays the channel the detection level of which is currently indicated in (CH-OUT). (For three seconds) Displays the selected channel in (CHOUT) (for three seconds) and indicates the detection level and threshold value of the selected channel. Registered Color Selection (Bank Selection Input) 1-output Models Only In the RUN mode, bank selection can be made externally with the bank selection input 1 (yellow) and input 2 (green). The selected bank is indicated by the bank selection indicator. NPN (E3MC-A11/-X11/-Y11) Bank 1 2 3 4 Input 1 OPEN GND OPEN GND Input 2 OPEN OPEN GND GND PNP (E3MC-A41/-X41/-Y41) Bank 1 2 3 4 Input 1 OPEN Vcc OPEN Vcc Input 2 OPEN OPEN Vcc Vcc External synchronous input function The measurement results will be directly output to the control output if the input from the external synchronous input terminal (pink) is set to OFF. The output will hold the previous status if the input of the external synchronous input terminal is set to ON. As for the 4-output models, this function applies to the output of all the channels. Sensing object ON Discrimination OFF result ON External synchronous input Control output Output on hold OFF ON OFF This status can be on hold by an external synchronous input. Output on hold Same color Different color Same color Same color This status can be on hold so that unwanted color objects can be ignored while they are passing the sensing range. A-156 Standard Photoelectric Sensors Remote teaching (remote control function) Mode Setting When using remote teaching (remote control function), you must set the Sensor to mode B. Setting Method Apply power to the Sensor while pressing the SELECT DOWN button and TEACH button at the same time. TEACH SELECT The following is an example of ladder programming. 00000 00100 TIM000 00100 END TIM000 set value No. 1: 0003 No. 2: 0006 No. 3: 0009 No. 4: 00012 No. 5: 00015 Input: 00000 Output: 00100 Others: Work bits TIM000 #XXXX Checking Method Whether the E3MC is operating in mode A or B can be checked with the operation indicator after mode setting (indicated for 3 s) or in the TEACH mode. Mode A: Operation indicator is OFF. OUTPUT The following is an example of a timing chart of teaching after bank selection. Input detection 1. 5s Remote control input 0. 3s ON OFF Operation in bank 2. specified Teaching. Input detection An interval of 0. 6 min. 1. 5s 1 2 CH- 3 OUT 4 Mode B: Operation indicator is ON. LEVEL THRESHOLD Sensing restarts. 0. 3s OUTPUT 1 2 CH- 3 OUT 4 Answerback output LEVEL THRESHOLD in bank 1. 0. 3s 0. 5s Answer-back output with normal signal reception. Answer-back output with teaching OK. The current mode selected does not change after the Sensor is turned OFF. The remote control function is available in the RUN mode or ADJ mode only. [. . . ] Insert the Fiber Unit further unit it comes in contact with the innermost end. Sensor installation Tighten the Fiber Unit with a screwdriver to a torque of 0. 2 Nm. Fibers Among the recommended fibers, the E32-CC200 and E32-D32L have white or dotted yellow lines on the fiber to be inserted into the emitter. When using the E3MC-(M)Y##, insert the fiber with the line into the emitter section at the bottom of the amp. Sensing dista q = 20° Sensing object Recommended Fiber: Reflective Optical Fiber The following optical fibers are recommended for use with the E3MC-(M)Y##. Model E32-DC200 E32-CC200*2 E32-D32L*3 Sensing distance*1 5 mm 5 mm 4. 5 mm Common to Fiber Units Mounting Tightening Force · The tightening force applied to the Fiber Unit should be as follows: (Screwed type) (Columnar type) Mounting bracket Toothed washer Flat or pan head set screw (M3 max. ) E32-D11L 5 mm *1. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3MC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3MC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.