User manual OMRON CX-PROGRAMMER INTRODUCTION GUIDE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON CX-PROGRAMMER. We hope that this OMRON CX-PROGRAMMER user guide will be useful to you.
You may also download the following manuals related to this product:
OMRON CX-PROGRAMMER (346 ko)
OMRON CX-PROGRAMMER INTRODUCTION GUIDE (3297 ko)
OMRON CX-PROGRAMMER INTRODUCTION GUIDE (2625 ko)
OMRON CX-PROGRAMMER INTRODUCTION GUIDE (6712 ko)
OMRON CX-PROGRAMMER INTRODUCTION GUIDE (8799 ko)
Manual abstract: user guide OMRON CX-PROGRAMMERINTRODUCTION GUIDE
Detailed instructions for use are in the User's Guide.
[. . . ] Introduction
- Please be sure to read and understand Precautions and Introductions in CX-Programmer Operation Manual before using the product. - This Guide describes the basic operation procedure of CX-Programmer. Refer to the Help or the Operation Manual of the PDF file for detailed descriptions. - You can display the PDF files from the [Start] menu on your desktop after installing the CX-Programmer. [. . . ] You can set hiding of the comment entry dialog.
[Tools] -> [Options]
Click the check box to remove the check mark. The comment entry dialog is not displayed anymore.
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
5-3. Edit of Symbol Comment
Click
Ladder Window is switched to the Symbol Comment Editing window. Double-click the left mouse button on a bit number that you want to enter a symbol comment, and you will able to enter a symbol comment. Copy&Paste and deletion of one or more comments are possible by the cell. Copy&Paste and deletion of one or more comments are possible by the cell. Drag the mouse with the right mouse button pressed to invert the source bits of copy in blue. Click the right mouse button on the range, and select [Copy] from the popup menu. Copy&Paste of symbol Copy&Paste of symbol comments is possible between comments is possible between Excel and CX-Programmer too. Example of copying & pasting comments of two bits
Click the right mouse button on the bit number of the copy destination, and select [Paste].
The comments of the selected two bits are copied.
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
5-4. (The rung is inverted in blue. )
ENT
The entry screen shows up.
[Process_at_Startup] Enter a rung comment.
ENT
5-5. Entry of Normally Closed Contact /
Press "/" from a keyboard to show the [New Closed Contact] dialog.
1
ENT Sensor 1
ENT
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
O ENT
101
Coil 1 ENT R
5-6. Entry of Attached Comments
This function is very useful for keeping change histories at maintenance and notes of debug bits at startup. Move the cursor to the contact to which you want to write an annotation.
Alt
ENT
The entry screen shows up.
Or click the right mouse button. 2002 Added by Tanaka, Maintenance Dept. ].
ENT
Press [Alt] + [A] to switch showing/hiding of attached comments.
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
5-7. Entry of Differential Contact. . . Up C
100
Click
Click [Up].
ENT
This entry method is available only for CS/CJ and CV series PLCs. For the other series PLCs, use DIFD (14).
ENT
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
5-9. Entry of Vertical. . . Up Ctrl
Or
U
O ENT
200
Coil 2
ENT
R
C ENT O ENT
200
ENT
300
Coil 3 ENT
5-10. Entry of Vertical. . . Down
Ctrl
Or
V
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
5-11. Entry of Advanced Instructions 1 - Entry of Strings I
Show the [New Instruction] dialog.
Enter an instruction and its operand.
++ d0
ENT
See the next page for the contents of instructions.
Enter a comment.
Products
ENT
R
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
5-12. Entry of Advanced Instructions 1 - Useful Functions
Click
Instruction Help Function Click The reference guide screen of the . instruction shows up.
Find Instruction Function Click .
The list of advanced instructions per function shows up.
PLCs supporting the applicable instruction are listed.
Installation Installation to Startup to Startup
Opening a Opening a new project new project
Device type Device type settings settings
Creating a Creating a program program
5-13. [. . . ] (1)The reason why the coil 3. 00 is not turned on is that its contact 2. 00 is not turned on. (2)Move the cursor to the following position (contact 2. 00) and press the [Space] key.
Space
(3)The reason why the coil 2. 00 is not turned on is that the contact 1. 00 or 1. 01 is not turned on. Move the cursor to the contact 1. 00 and press the [Space] key as well as the above operation (2).
Space
(4)If this rung is not a cause press [Shift]+[Space], and you will able to go back to the rung before you started to find this rung.
Shift
Space
Online Online to Transfer to Transfer
Monitoring Monitoring
Force On Force On Force Off Force Off
Program Program Check Check
Online Online Edit Edit
(5)Then retrace rungs to find a cause from the contact 1. 01. As well as the operations so far, move the cursor to the contact 1. 01 and press the [Space] key.
Space
(6)The focus moves to the coil 1. 01. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CX-PROGRAMMER
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CX-PROGRAMMER will begin.