User manual OMRON CX-INTEGRATOR V2 12-2009

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON CX-INTEGRATOR V2. We hope that this OMRON CX-INTEGRATOR V2 user guide will be useful to you.


OMRON CX-INTEGRATOR V2 12-2009: Download the complete user guide (8152 Ko)

Manual abstract: user guide OMRON CX-INTEGRATOR V212-2009

Detailed instructions for use are in the User's Guide.

[. . . ] W464-E1-06 SYSMAC CXONE-AL_C-V4/ CXONE-AL_D-V4 CS/CJ/CP/NSJ Series CX-Integrator Ver. 2. @ Operation Manual Revised December 2009 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Failure to heed precautions can result in injury to people or damage to property. !DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. [. . . ] Note: Changing or removing a routing table refers to using the 3-24 3-2 Setting the Routing Tables 3-2-5 Transferring Routing Tables to a Directly Connected PLC CX-Integrator (or a CX-Integrator for another personal computer) to start the Routing Table Component and then changing or removing a routing table for the target PLC (either a local network table or a relay network table). Note If routing tables are transferred to the PLC from a Programming Device, the CPU Bus Unit will be reset. The Unit is reset in order to read and enable the routing tables that were transferred. Before executing the routing table transfer, verify that no equipment will be damaged and it is safe for the CPU Bus Unit to be reset. When transferring to a different network layer, directly connect the CX-Integrator to a PLC in that network and transfer the routing tables. Note 3-25 3-2 Setting the Routing Tables 3-2-6 Saving Routing Tables 3-2-6 Saving Routing Tables Use the following procedure to save the created FINS local routing tables. The FINS local routing tables are saved in a file with the ". rtg" filename extension or the ". rxg" filename extension (see note). Select File ­ Save Local Routing Table File in the PLC Routing Table Window. Input the desired filename ("Sample" is input in this example), specify the directory where the file will be saved, and click the Save Button. The file will be saved with either the ". rtg" or ". rxg" filename extension attached. (The file is "Sample. rtg" in this example. ) Note: The file's filename extension depends on the relay network's registration mode. · Standard mode: *. rtg · Extended mode: *rxg 3-2-7 Reading Routing Tables Use the following procedure to read FINS local routing tables that were previously saved. Select File ­ Open Local Routing Table File in the PLC Routing Table Window. Select a FINS local routing table file to read (with a ". rtg" or ". rxg" filename extension, see note) and click the Open Button. Once the file is read, the PLC can be connected online and the file can be transferred to the PLC. Note: The ". rxg" files are supported by CX-Integrator Version 2. 1 or higher. 3-2-8 Verifying Routing Tables Use the following procedure to compare routing tables created in the CX-Integrator to the routing tables in the PLC. Select Options ­ Verify Routing Table in the PLC Routing Table Window. The results of the verification will be displayed. Normal Result Error Detected Click the OK Button to display detailed verification results. Local Network Table Results Relay Network Table Results 3-26 3-2 Setting the Routing Tables 3-2-9 Printing Routing Tables 3-2-9 Printing Routing Tables Use the following procedure to print the created routing tables. Example Printout (PLC1 Table View) Example Printout (PLC1 Main View) 3-27 3-2 Setting the Routing Tables 3-2-10 Transferring Routing Tables to a Network PLC through a Direct Serial Connection 3-2-10 Transferring Routing Tables to a Network PLC through a Direct Serial Connection Use the following procedure to transfer the FINS local routing tables to a PLC in the network (see note 2) through the PLC that is connected by a direct serial connection with network address 0 and node address 0. Note 1: The following conditions are required to use this function. · The PLC must have a CS/CJ-series CPU Unit with unit version 4. 0 or later. Note 2: The FINS local routing tables can be transferred only to a PLC in the same network as the PLC connected directly by a direct serial connection. The transfer cannot cross a network level to another network. The following example shows how to transfer the routing tables to PLC2, PLC3, PLC4, and PLC5, which are in the same network as directly connected PLC1, as shown in the network configuration diagram. Computer (CX-Integrator) The local network table is not set in this PLC. Initial connection to PLC1 Ethernet Unit with unit number 0 Controller Link Unit with unit number 1 PLC2 Node address 2 PLC3 Node address 3 Direct serial connection Network address 0 Controller Link Connect online with network address = 0, and node address = 0. PLC4 Node address 2 PLC5 Node address 3 Network address 0 Ethernet Note The data transfer procedure described in this section is applicable to the FINS local routing tables only. Transfer Procedure 1. [. . . ] If the EDS file already exists, the new EDS file will overwrite the previous one. If the EDS files are different to each other in version, the new EDS file will be added to the Hardware List as shown below. Note: When using Windows Vista or Windows 7, refer to Appendix 3. It provides precautions when installing Expansion Modules. A-5 A-2 EDS File Management A-2-2 Creating EDS Files A-2-2 Creating EDS Files Tools - EDS File - Create The EDS files are required by the CX-Integrator to create a network configuration. The device information can be obtained from the device on the network if the network is online. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CX-INTEGRATOR V2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CX-INTEGRATOR V2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.