User manual OMRON CJ2H-CPU65-EIP DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON CJ2H-CPU65-EIP. We hope that this OMRON CJ2H-CPU65-EIP user guide will be useful to you.


OMRON CJ2H-CPU65-EIP DATASHEET: Download the complete user guide (533 Ko)

Manual abstract: user guide OMRON CJ2H-CPU65-EIPDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] SYSMAC CJ-series CJ2H (Built-in EtherNet/IP) CPU Units CJ2H-CPU6@-EIP CSM_CJ2H-CPU-EIP_DS_E_2_1 Flagship PLCs with Built-in Multifunctional Ethernet Port · Small, Fast, Flexible: The CJ2 CPU Units inherit and improve CJ1 features while also adding EtherNet/IP as a standard feature for high-speed, high-capacity Ethernet-based networking. CJ2H-CPU6@-EIP Features · · · · · High-speed, high-capacity EtherNet/IP is built into every model. The CIP communications protocol is supported for direct access to multivendor devices. Superior high-speed control performance: LOAD instructions execute in 16 ns, SINE instructions in 0. 59 s. 1 CJ2H-CPU6@-EIP Ordering Information CJ2H (Built-in EtherNet/IP) CPU Units Specifications Product name I/O capacity/Mountable Units (Expansion Racks) Program capacity LD instruction execution time Current consumption (A) Model 5V 24 V Standards Data memory capacity 832K words DM: 32K words EM: 32K words × 25 banks 512K words DM: 32K words EM: 32K words × 15 banks 352K words DM: 32K words EM: 32K words × 10 banks 160K words DM: 32K words EM: 32K words × 4 banks 160K words DM: 32K words EM: 32K words × 4 banks 400K steps CJ2H (Built-in EtherNet/IP) CPU Units 2, 560 points / 40 Units (3 Expansion Racks max. ) CJ2H-CPU68-EIP 250K steps CJ2H-CPU67-EIP 0. 82 (See note. ) UC1, N, L, CE 150K steps 0. 016 s - CJ2H-CPU66-EIP 100K steps CJ2H-CPU65-EIP 50K steps CJ2H-CPU64-EIP Note: Add 0. 15 A per Adapter when using NT-AL001 RS-232C/RS-232A Adapters. Add 0. 04 A per Adapter when using CJ1W-CIF11 RS-422A Adapters. International Standards · The standards indicated in the "Standards" column are those current for UL, CSA, cULus, NK, and Lloyd standards and EC Directives as of the end of April 2008. [. . . ] Errors can be generated for user-specified conditions: Non-fatal errors (FAL) and fatal errors (FALS). Program section time diagnosis and program section logic diagnosis are supported (FPD instruction). This function turns OFF all outputs from Output Units when an error occurs. The RUN output from the CJ1W-PA205R turns ON while CPU Unit is in RUN mode or MONITOR mode. This function provides alarm information from Basic I/O Units that have load short-circuit protection. The time and logic of an instruction block can be analyzes using the FPD instruction. This function indicates when the CPU Unit is on standby because all Special I/O Units and CPU Bus Units have not been recognized at the startup in RUN or MONITOR mode. System FAL Error Detection This function generates a non-fatal (FAL) error when the user-defined conditions are met in (User-defined non-fatal error) program. Duplicate Refreshing Error Detection Backup Memory Error Detection PLC Setup Error Detection Non-fatal Error Detection CPU Bus Unit Error Detection Special I/O Unit Error Detection Tag Memory Error Detection Battery Error Detection CPU Bus Unit Setting Error Detection Special I/O Unit Setting Error Detection Memory Error Detection Selfdiagnosis and Restoration (Continued from previous page) I/O Bus Error Detection Unit/Rack Number Duplication Error Too Many I/O Points Error Detection I/O Setting Error Detection Program Error Detection Instruction Processing Error Detection Fatal Error Detection Indirect DM/EM BCD Error Detection Illegal Area Access Error Detection No END Error Detection Task Error Detection Differentiation Overflow Error Detection Invalid Instruction Error Detection User Program Area Overflow Error Detection Cycle Time Exceeded Error Detection This function detects an error when an immediate refreshing Instruction in an interrupt task is competing with I/O refreshing of a cyclic task. This function detects errors in the memory backup of the user programs and parameter area (backup memory). This function detects an error when there is an error in data exchange between the CPU Unit and a CPU Bus Unit. This function detects an error when there is an error in data exchange between the CPU Unit and a Special I/O Unit. This function detects an error when a battery is not connected to the CPU Unit or when the battery voltage drops. This function detects an error when the model of a CPU Bus Unit in the registered I/O tables does not agree with the model that is actually mounted in the PLC. This function detects an error when the model of a Special I/O Unit in the registered I/O tables does not agree with the model of Unit that is actually mounted. This function detects when an error occurs in data transfers between the Units mounted in Rack slots and the CPU Unit and detects when the End Cover is not connected to the CPU Rack or an Expansion Rack. This function detects an error when the same unit number is set for two or more Units, the same word is allocated to two or more Basic I/O Units, or the same rack number is set for two or more Racks. This function detects an error when the total number of I/O points set in the I/O tables or the number of Units per Rack exceeds the specified range. This function detects an error when the number of Units in the registered I/O tables does not agree with the actual number of Units that is mounted, or an Interrupt Unit has been connected in the wrong position, i. e. , not in slot 0 to 3. This function detects an error when the given data value is invalid when executing an instruction, or execution of instruction between tasks was attempted. This function detects an error when an indirect DM/EM address in BCD mode is not BCD. This function detects an error when an attempt is made to access an illegal area with an instruction operand. This function detects an error when there is no END instruction at the end of the program. [. . . ] For communications commands addressed to Special I/O Units or CPU Bus Units, refer to the operation manual for the related Unit. W446 W447 CX-Programmer Operation Manual WS02-CX-V@ CX-Programmer Operation Manual Functions Blocks CX-Programmer Operation Manual SFC Programming CXONE-ALD-V@ CS/CJ/CP/NSJ-series CX-Integrator Network Configuration Software Operation Manual CX-One Setup Manual Support Software for Windows computers CX-Programmer operating procedure Describes operating procedures for the CX-Programmer. Also refer to the Software User's Manual (W473) and Instructions Reference Manual (W474) when you do programming. W469 W464 Network setup and monitoring Describes the operating procedures for the CX-Integrator. W463 Installing software from the CX- Provides an overview of the CX-One FA Integrated Tool One Package and describes the installation procedure. 14 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CJ2H-CPU65-EIP




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CJ2H-CPU65-EIP will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.