User manual OMRON CIMR-E7Z DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON CIMR-E7Z. We hope that this OMRON CIMR-E7Z user guide will be useful to you.


OMRON CIMR-E7Z DATASHEET: Download the complete user guide (4960 Ko)

You may also download the following manuals related to this product:

   OMRON CIMR-E7Z DATASHEET (912 ko)
   OMRON CIMR-E7Z DATASHEET (3989 ko)
   OMRON CIMR-E7Z DATASHEET (4004 ko)
   OMRON CIMR-E7Z DATASHEET (3510 ko)
   OMRON CIMR-E7Z DATASHEET (3899 ko)
   OMRON CIMR-E7Z DATASHEET (3921 ko)
   OMRON CIMR-E7Z DATASHEET (4078 ko)
   OMRON CIMR-E7Z DATASHEET (3939 ko)
   OMRON CIMR-E7Z DATASHEET (4010 ko)
   OMRON CIMR-E7Z DATASHEET (3997 ko)
   OMRON CIMR-E7Z DATASHEET (4003 ko)
   OMRON CIMR-E7Z QUICK GUIDE (482 ko)
   OMRON CIMR-E7Z QUICK GUIDE (1135 ko)

Manual abstract: user guide OMRON CIMR-E7ZDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] 2. DC reactor 12-pulse input Standard 4-pole motors are used for max. Choose the inverter model whose rated current is allowable within the motor rated current range. A 3-wire transformer is required on the power supply for 12-phase rectification. 400 V class Model CIMR-E7ZZ@ IP54 model: CIMR-E7Z 40P4 40P7 41P5 42P2 43P7 44P0 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 --------2. 2 4. 0 5. 3 --3. 7 5. 8 7. 6 --4. 0 6. 6 --- 47P52 40112 40152 40182 40222 40302 40372 40452 40552 --5. 5 9. 5 7. 5 13 11 18 24 15 18. 5 22 24 31 30 39 34 45 30 46 60 37 57 75 45 69 91 55 85 75 --90 ------------110 132 160 185 220 300 Max. applicable motor Kw 0. 55 0. 75 1. 5 output1 Output characteristics Inverter capacity kVA 1. 4 Rated current Max. [. . . ] weight kg Cooling method 157 1 140 280 177 200 2 240 254 279 3 380 453 300 310 350 380 535 615 809 1027 197 207 258 298 328 348 186 216 195 220 250 325 300 350 400 450 600 725 285 335 385 435 575 12. 5 700 302 7. 5 8 0 10 0 30 135 165 209 126 280 266 7 --- 39 5 59 65. 5 78 2. 3 M6 M5 3 Self cooled 200 V class (3-phase) 3. 7 5. 5 7. 5 11 15 18. 5 22 30 37 45 55 75 0. 4 0. 75 1. 5 2. 2 3. 7 4. 0 5. 5 4 6 7 11 24 Fan cooled 100 27 62 68 94 95 130 3. 2 M10 157 1 140 280 177 126 280 266 7 --- 39 5 59 M5 3 Self cooled 4 400 V class (3-phase) 7. 5 11 15 18. 5 22 30 37 45 55 75 90 110 132 160 200 2 240 275 300 350 535 197 207 258 186 216 220 300 350 450 285 335 435 8 --- 65. 5 78 100 2. 3 M6 6 10 24 Fan cooled 7. 5 85 325 3 453 504 579 715 283 260 550 535 105 12. 5 15 45. 8 302 105 40 96 97 122 4. 5 M12 130 170 1027 1243 1324 348 358 378 325 370 445 725 850 918 700 820 855 3. 2 130 M10 393 408 140 Varispeed E7 313 Enclosed wall-mounted inverters (IP54 type) W D W1 4-d H t1 Voltage Max. applicable motor Inverter output kW CIMR-E7Z@ 7. 5 47P52 40112 40152 40182 40222 40302 40372 40452 40552 Dimensions in mm W H D 240 350 600 260 410 650 300 370 620 12 2. 5 M10 260 576 9 2. 5 M8 30 43 W1 H1 H2 T1 d Approx. rubber bush) MTG screw D B C 30 or more A 30 or more 150 150 or more C 260 200 or more 50 or more A 50 or more Model Voltage LKEB-_ 20P7 21P5 220 V class 22P2 23P7 25P5 25P5 40P7 41P5 400 V class 42P2 43P7 45P5 47P5 Dimensions in mm A 105 130 130 130 250 250 105 130 130 130 250 250 B 275 350 350 350 350 350 275 350 350 350 350 350 C 50 75 75 75 200 200 50 75 75 75 200 200 D 260 335 335 335 335 335 260 335 335 335 332 332 MTG screw M5 x 3 M5 x 4 M5 x 4 M5 x 4 M6 x 4 M6 x 4 M5 x 3 M5 x 4 M5 x 4 M5 x 4 M6 x 4 M6 x 4 Weight kg 3. 0 4. 5 4. 5 5. 0 7. 5 8. 5 3. 0 4. 5 4. 5 5. 0 7. 5 8. 5 Voltage Model LKEB@ 2011 2015 2018 2022 4011 4015 4018 Dimensions in mm A 266 356 446 446 350 350 446 446 356 446 446 B 543 543 543 543 412 412 543 543 956 956 956 C 246 336 426 426 330 330 426 426 336 426 426 D 340 340 340 340 325 325 340 340 740 740 740 MTG screw M8 x 4 M8 x 4 M8 x 4 M8 x 4 M6 x 4 M6 x 4 M8 x 4 M8 x 4 M8 x 4 M8 x 4 M8 x 4 B 100 or less 100 or less Lead wire inlet (28 dia. rubber bush) 4-M6 MTG holes Weight kg 10 15 19 19 16 18 19 19 25 33 33 220 V class 400 V class 4022 4030 4037 4045 316 Frequency inverters Attachments Heatsink external mounting attachment The Varispeed E7 inverters under the 200/400 V class 18. 5 kW or less need this attachment for mounting the heatsink externally. This attachment expands the outer dimensions of the width and height of the inverter. (Attachment is not required for inverters of 22 kW or more. ) Mounting panel Wall Model CIMRE7Z@ 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 Dimensions in mm W H W1 H1 D1 D2 D3 Attachment order code 37. 4 EZZ08676A 155 302 126 290 122. 6 57. 4 EZZ08676B EZZ08676C 210 250 330 392 180 216 316 136. 1 63. 4 372 133. 6 76. 4 37. 4 EZZ08676A 155 302 126 290 122. 6 57. 4 EZZ08676B EZZ08676C 210 250 330 392 180 216 316 136. 1 63. 4 372 133. 6 76. 4 40 60 70 85 40 H1 H 60 70 85 W1 W D1 D2 D3 or more Panel cut for external mounting of cooling fin (heatsink) (H3) 4-d Tap a b 2-5 Dia. holes (H3) 4-d Tap a a a (H2) (W3) (W2) A (W3) (W2) (W3) A (W3) (H3) a b a W1 W (W2) (W2) (59) Fig 1 4-d Tap a a W1 W (H3) a a (H2) Fig 3 (W3) A (W3) (W2) (W2) (H2) W1 W (H3) a a Fig 2 Model CIMRE7Z@ 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 1. Drawing W Dimensions in mm H W1 (W2) (W3) H1 (H2) (H3) A B d (H2) (19) 155 302 126 1 210 330 180 6 8. 5 290 9. 5 6 138 271 M5 B H1 H B H1 H 6. 5 8. 5 8. 5 3 316 9 7 10 7. 5 197 298 233 353 M6 244 369 269 419 359 545 M10 434 673 484 782 M12 555 817 250 392 216 250 400 195 24. 5 275 450 220 375 600 250 2 450 725 325 500 850 370 575 885 445 57 55 54. 5 372 9. 5 385 435 575 8 15 8 700 13. 5 8 10 820 855 19 12. 5 (H3) 15 B 155 302 126 1 210 330 180 6 8. 5 290 9. 5 6 138 271 M5 H1 H 6. 5 8. 5 8. 5 3 24. 5 8 8 8 10 316 9 7 10 197 298 233 353 269 419 M6 250 392 216 275 450 220 325 550 260 2 450 725 325 54. 5 500 850 370 3 575 925 445 57 55 372 9. 5 435 8 535 7. 5 309 519 700 13. 5 12. 5 434 673 M10 820 895 19 1 15 15 484 782 555 817 M12 The sizes are different between the top and the bottom. Refer Fig 3 Varispeed E7 317 Installation Standard connections DC reactor to improve input power factor (optional) U Short-circuit bar X Main contactor Fuse 1 2 Varispeed E7 R/L1 U/T1 Motor V/T2 W/T3 3-phase power supply 380 to 480 V 50/60 Hz L1 L2 L3 PE Line filter* S/L2 T/L3 CIMRE7Z47P5 M Forward run/stop Reverse run/stop External fault Fault reset Multi-function digital inputs [Factory settings] Multi-step speed setting 1 Multi-step speed setting 2 Jog frequency selection S1 S2 S3 S4 S5 S6 S7 SN SC SP E(G) 24 V Shield terminal Shield terminal MA MB MC Fault contact output 250 VAC, 1 A max. 30 VDC, 1 A max. M1 M2 M3 M4 Contact output 1 [Default: During run] Contact output 2 [Default: Zero speed] Multi-function digital output 250 VAC, 1 A max. 30 VDC, 1 A max. E(G) Adjustment 3 2k 1 4 to 20 mA P P 0 to 10 V 2 2k +V Analog input power supply +15 V, 20 mA A1 Analog input 1: Master frequency reference 0 to 10 V (20 k) FM A2 Multi-function analog input 1: [Default: Frequency Bias 4 to 20 mA (250 )] AC -V 0V Analog input power supply -15 V, 20 mA Terminating resistance Adjustment, 20 k + FM - Multi-function analog output 1 (0 to 10 V, 2 mA) [Default: Output frequency, 0 to 10 V] Adjustment, 20 k AM + AM - Multi-function analog output 2 (0 to 10 V, 2 mA) [Default: Output power, 0 to 10 V] AC R+ P MEMOBUS communication RS-485/422 P RS+ SIG Shielded wires P Twisted-pair shielded wires *E7 IP54 types has RFI filter included as standard 318 Frequency inverters Main circuit Voltage Model CIMR-E7Z@ Max. applicable motor output R/L1 S/L2 T/L3 R1/L11 S1/L21 T1/L31 U/T1 V/T2 W/T3 1 2 3 /l2 r/l1 200 / l2 200 400 / l2 400 PE ( 1. ) DC reactor ( 1- 2) DC power supply1 ( 1- ) ------------Ground terminal (100 or less) DC power supply ( 1- 2)1 Braking unit ( 3- ) Cooling fan power supply2 DC reactor ( 1- 2) DC power supply1 ( 1- ) ------Cooling fan power supply3 DC power supply ( 1- 2)1 Braking unit ( 3- ) Inverter output Inverter output --Main circuit input power supply Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment (see P59). Main circuit input power supply Main circuit input power supply R-R1, S-S1 and T-T1 have been wired before shipment 20P4 to 2018 0. 4 to 18. 5 kW 200 V 2022, 2030 22 to 30 kW 2037 to 2110 37 to 110 kW 40P4 to 4018 0. 4 to 18. 5 kW 400 V 4022 to 4055 22 to 55 kW 4075 to 4300 75 to 300 kW --- Ground terminal (10 or less) 1 - DC power input does not conform to UL/c-UL listed standard. Cooling fan power supply r/l1- /l2: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz (A transformer is required for 230 V 50 Hz or 240 V 50/60 Hz power supply. ) Cooling fan power supply r/l1 - 200 / l2 200: 200 to 220 VAC 50 Hz, 200 to 230 VAC 60 Hz, r/l1 - 400 / l2 400: 380 to 480 VAC 50/60 Hz Main circuit configuration CIMR-E7Z20P4 to 2018 CIMR-E7Z2022, 2030 CIMR-E7Z2037 to 2110 200 V class CIMR-E7Z40P4 to 4018 CIMR-E7Z4022 to 4055 CIMR-E7Z4075 to 4300 400 V class CIMR-E7Z47P5 to 40182 CIMR-E7Z40222 to 40552 400V class IP54 1 2 R/L1 S/L2 T/L3 EMC filter U/T1 V/T2 W/T3 Power supply Control circuits Varispeed E7 319 Control circuit Type No. S1 S2 Digital input signals S3 S4 S5 S6 S7 SC SN SP Analog input signals +V A1 A2 AC E(G) M1 Digital output signals Running signal (1NO contact) M2 Multi-function contact outputs M3 Zero speed M4 MA MB MC Analog output signals FM AC AM R+ RS+ SIG Multi-function analog output (frequency output) Analog common Multi-function analog output (current monitor) MEMOBUS communications input For 2-wire RS-485, short R+ and S+ as well as R- and S-. MEMOBUS communications output Signal common ­ Differential input, photocoupler isolation ­ 0 to 10 V, 10 V=100% output frequency ­ 0 to 10 V, 10V = 200% of the inverter rated current Multi-function analog output 2 Differential input, photocoupler isolation Multi-function analog output 1 0 to +10 V max. Fault output signal Fault when CLOSED across MA and MC Fault when OPEN across MB and MC Zero level (b2-01) or below when ON Relay contacts contact capacity: 1 A max. Signal name Forward run/stop command Reverse run/stop command External fault input*1 Fault reset*1 Multi-step speed reference 1*1 (Master/auxiliary switch) Multi-step speed reference 2*1 Jog frequency reference*1 Digital input common Digital input neutral Digital input power supply 15 V power output Frequency reference Multi-function analog input Analog reference common Shield wire, optional ground line connection point Function Forward run when ON; stopped when OFF. Reset when ON Auxiliary frequency reference when Functions are selected by setting H1-01 to H1-05. ­ ­ +24 VDC power supply for digital inputs 15 V power supply for analog references 0 to +10 V/100% 4 to 20 mA/100% 0 V to +10 V/100% 0 to 20 mA/100% ­ ­ Function is selected by setting H3-09. current: 20 mA) 0 to +10 V (20 k) 4 to 20 mA (250 ) 0 V to +10 V (20 k) 0 to 20 mA (250 ) ­ ­ 24 VDC, 8 mA photocoupler isolation Signal level Note: RS-485/422 1. The default settings are given for terminals S3 to S7. For a 3-wire sequence, the default settings are a 3-wire sequence for S5, multi-step speed setting 1 for S6 and multi-step speed setting 2 for S7. [. . . ] applicable motor output kW 0. 4 0. 75 1. 5 2. 2 3. 7 5. 5 7. 5 11 15 18. 5 22 30 37 45 55 75 90 110 0. 4 0. 75 1. 5 2. 2 3. 7 5. 5 7. 5 11 15 18. 5 22 Model CIMR-E7Z@ 20P4 20P7 21P5 22P2 23P7 25P5 27P5 2011 2015 2018 2022 2030 2037 2045 2055 2075 2090 2110 40P4 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 4037 4045 4055 4075 4090 4110 4132 4160 4185 4220 4300 Model CDBR@ No. of used Model LKEB@ 20P7 20P7 21P5 22P2 Specifications of resistor 70 W 70 W 260 W 260 W 390 W 520 W 780 W 2400 W 3000 W 3000 W 4800 W 3000 W 3000 W 4800 W 4800 W 4800 W 4800 W 4800 W 70 W 70 W 260 W 260 W 390 W 520 W 780 W 1040 W 1560 W 4800 W 4800 W 6000 W 9600 W 9600 W 6000 W 9600 W 6000 W 6000 W 9600 W 9600 W 9600 W 9600 W 9600 W 200 200 100 70 40 30 20 13. 6 10 10 6. 8 10 10 6. 8 6. 8 6. 8 6. 8 8 750 750 400 250 150 100 75 50 40 32 27. 2 20 16 13. 6 20 13. 6 20 20 13. 6 13. 6 13. 6 16 13. 6 No. of used 1 1 1 1 1 1 1 1 1 1 1 2 2 2 2 3 4 5 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 2 3 3 4 4 4 5 6 Braking torque % 220 125 125 120 125 115 125 125 125 125 125 125 100 120 100 110 120 100 230 130 125 135 135 135 130 135 125 125 125 125 125 125 135 145 100 100 140 140 120 110 110 Connectable min resistance value 48 48 48 16 16 16 9. 6 9. 6 9. 6 9. 6 6. 4 9. 6 9. 6 6. 4 6. 4 1. 6 1. 6 1. 6 96 96 64 64 32 32 32 20 20 19. 2 19. 2 19. 2 12. 8 12. 8 19. 2 12. 8 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 3. 2 2015B 1 23P7 25P5 27P5 2011 2015 2015 2022 2015 2015 2022 2022 2022 2022 2018 40P7 40P7 41P5 42P2 43P7 45P5 47P5 4011 4015 4018 4022 4030 200 V class 2022B 2015B 2015B 2022B 2022B 2110B 2110B 2110B 1 2 2 2 2 1 1 1 4030B 1 400 V class 30 37 45 55 75 90 110 132 160 185 220 300 4045B 4045B 4030B 4045B 4220B 4220B 4220B 4220B 4220B 4220B 4220B 1 1 2 2 1 1 1 1 1 1 2 4037 4045 4030 4045 4030 4030 4045 4045 4045 4037 4045 1. 3. Load factor during deceleration to stop a load with constant torque. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CIMR-E7Z




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CIMR-E7Z will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.