User manual OMRON 61F-GP-N8 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON 61F-GP-N8. We hope that this OMRON 61F-GP-N8 user guide will be useful to you.


OMRON 61F-GP-N8 DATASHEET: Download the complete user guide (585 Ko)

You may also download the following manuals related to this product:

   OMRON 61F-GP-N8 DATASHEET (586 ko)
   OMRON 61F-GP-N8 DATASHEET (791 ko)
   OMRON 61F-GP-N8 DATASHEET (758 ko)
   OMRON 61F-GP-N8 DATASHEET (463 ko)
   OMRON 61F-GP-N8 DATASHEET (224 ko)
   OMRON 61F-GP-N8 DATASHEET (188 ko)
   OMRON 61F-GP-N8 DATASHEET (144 ko)
   OMRON 61F-GP-N8 DATASHEET (536 ko)

Manual abstract: user guide OMRON 61F-GP-N8DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Compact 8-pin Type Ordering Information List of Models Application General-purpose type Long-distance type High-sensitivity type Low-sensitivity type Two-wired type 2 km 4 km Model number 61F-GP-N8 61F-GP-N8L 2KM 61F-GP-N8L 4KM 61F-GP-N8H 61F-GP-N8D 61F-GP-N8R Conductive Level Controller 61F-GP-N8 E-5 Level Controllers Accessories (Order Separately) Selection Guide for Electrode Holders and Separators Electrode Holders Applications For city water and other general-use electrodes. Easy-to-replace separate versions facilitate maintenance of electrodes. Ideal for soft drink vendors, etc. , where only limited space is available. In sewage use, electrode holders must be installed 10 to 20 cm apart from one another. [. . . ] Water Supply · Connect electromagnetic switch coil terminal A to terminal 2. · The pump stops when the water level reaches E1 and starts when the water level drops below E2. 200-VAC power supply 2. Drainage · Connect the electromagnetic switch coil terminal A to terminal 3. · The pump starts when the water level reaches E1 and stops when the water level drops below E2. 61F-GP-N8 MCCB 0V 8V 24 V Control circuit 200 V (See note 1 below. ) Contactor (See note 2 below. ) THR Tank PS-3S Stop Start Reservoir Note: 1. The earth terminal must be earthed. E-8 Conductive Level Controller 61F-GP-N8 Operation The Conductive Level Controller consists of a plug-in controller connected to a set of stainless steel probes. A low voltage is applied between these probes and the earth probe (or tank, if it is electrically conductive). The water provides a current between the earth probe and the high-level probe. The output relay in the Controller is energized when the water level reaches the high-level probe and de-energized when the water level falls below it. In this case the relay does not de-energize until the water level falls below the low-level probe. Using the low-level probe allows a wide differential between switching a pump on and off, and can avoid excessive pump operation during tank emptying or filling. If this differential is not required, the low-level probe need not be connected. Surge Suppressor Unit (61F-03B/04B) A high-capacity protective device is available which protects 61Fseries Floatless Level Controllers against faults arising from electrical surges (such as indirect strokes of lightning) when the Controllers are employed in elevated water tanks or in high-altitude locations. When connecting the Surge Suppressor Unit, wire as shown in the following example (with three electrodes). Discharge start voltage Impulse withstand voltage Impulse withstand current 90 V ±20 VDC 200, 000 V (1 x 40 µs) 6, 000 A (1 x 40 µs) 61F-03B Internal Connections 61F-03B 61F-04B Ground Ground E1 E2 E3 Connection Sockets PF113A-E Track-mounted Socket PL11 Back-connecting Socket Precautions 1. Mount the Surge Suppressor Unit as close to the Controller as possible. When grounding the Surge Suppressor Unit in the vicinity of the Controller, connect the ground side of the Surge Suppressor Unit to electrode E3. Long distance 61F-03B Ground Conductive Level Controller 61F-GP-N8 E-9 Level Controllers Specifications Dimensions Note: All units are in millimeters unless otherwise indicated. 61F-GPN8 91 PF083A-E Electrode Holders PS-@S 9-dia. rubber bushing (inner) PF2 parallel thread (effective dia. : 58. 135) PS-3S/-3SR 34 dia. E2 PS-4S/-4SR E3 E2 PS-5S/-5SR E3 E2 80 92 E3 13 40 26 20 80 E1 E4 E1 E4 E1 Mounting Holes Used with coupling PF2 Screw Holes Used with mounting bracket 65-dia. hole PS-31 PF1/2 Parallel thread 11 38. 5 32 7 12 11 dia. Mounting Holes 4 dia. Electrode SUS304 Dust preventive rubber cap (optional) 3 PF1/2 Rubber packing (see note) 26 M3 29. 5 dia. Note: Standard holder construction includes three integral 300-mm-long electrodes. However, a model having 1, 000-mm-long electrodes is available on request. BF-1 Terminal bolt SUS201 (M6) Nut (M6) 60 33 48 dia. [. . . ] If the sufficient interval cannot be provided, employ a low-sensitivity-type Floatless Level Controller. When taping one of the electrodes to prevent it from contacting the other electrodes in water, do not tape the electrode entirely but leave at least 100 mm of its end uncovered. When the required length of the electrode is more than 1 m, use a separator at each joint of two electrodes so as to prevent the electrodes from contacting one another. Usually, electrodes are used in a set of three: long, medium, and short. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON 61F-GP-N8




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON 61F-GP-N8 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.