User manual OMRON 3G3JV

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON 3G3JV. We hope that this OMRON 3G3JV user guide will be useful to you.


OMRON 3G3JV : Download the complete user guide (1114 Ko)

You may also download the following manuals related to this product:

   OMRON 3G3JV (2781 ko)

Manual abstract: user guide OMRON 3G3JV

Detailed instructions for use are in the User's Guide.

[. . . ] Simple, Compact Inverters 3G3JV Series Note: Do not use this document to operate the Unit. 66 Matsumoto Mishima-city, Shizuoka 411-8511 Japan Tel:(81)55-977-9181 Fax:(81)55-977-9045 Regional Headquarters Authorized Distributor: OMRON EUROPE B. V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel:(31)2356-81-300/Fax:(31)2356-81-388 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U. S. A. Tel:(1)847-843-7900/Fax:(1)847-843-8568 OMRON IDM Controls 9510 North Houston, Tx. [. . . ] output frequency Control C h t i ti characteristics Harmonic-current countermeasures Control method Carrier frequency Frequency control range Frequency precision (temperature characteristics) Frequency setting resolution Output frequency resolution Overload capacity External frequency set signal Acceleration/deceleration time Braking torque Voltage/frequency characteristics Protective functions f ti Motor protection Instantaneous overcurrent protection Overload protection Overvoltage protection Undervoltage protection Momentary power interruption compensation (selection) Cooling fin overheating Grounding protection Charge indicator (RUN indicator) Environment Location Ambient temperature Ambient humidity Ambient temperature Altitude Insulation resistance Vibration resistance Degree of protection 0. 2 0. 9 1. 2 0. 4 1. 4 1. 8 0. 75 2. 6 3. 4 1. 5 3. 7 4. 8 2. 2 4. 2 5. 5 3. 7 6. 6 8. 6 3-phase 380 to 460 V AC (according to the input voltage) 400 Hz parameter setting DC reactor (option) connection possible Sine wave PWM (V/f control) 2. 5 to 10. 0 kHz (in vector control) 0. 1 to 400 Hz Digital commands: ±0. 01% (­10°C to 50°C) Analog commands: ±0. 5% (25°C ± 10°C) Digital commands: 0. 1 Hz (less than 100 Hz) and 1 Hz (100 Hz or over) Analog commands: 0. 06 Hz/60 Hz (equivalent to 1/1000) 0. 01 Hz (calculated resolution) 150% of rated output current for 1 min Selectable with FREQ adjuster: 0 to 10 V DC (20 k), 4 to 20 mA (250 ), and 0 to 20 mA (250 ) 0. 0 to 999 s (Independent acceleration and deceleration time settings) Approx. 20% Set a user V/f pattern Protection by electronic thermal Stops at approx. 250% of rated output current Stops in 1 min at approximately 150% of rated output current Stops when main-circuit DC voltage is approximately 820 V Stops when main-circuit DC voltage is approximately 400 V Stops for 15 ms or more. By setting the Inverter to momentary power interruption mode, operation can be continued if power is restored within approximately 0. 5 s. Detects at 110°C ± 10°C Protection at rated output current level Lit when the main circuit DC voltage is approximately 50 V or less. Indoors (with no corrosive gas, oil spray, or metallic dust) Operating: ­10°C to 50°C Operating: 95% max. (Do not carry out any insulation resistance or withstand voltage tests) 9. 8 m/s2 max. between 20 and 50 Hz Panel-mounting models: Conforms to IP20 24 Specifications Terminal Block Position of Terminal Block Ground terminal Main circuit input terminals Control circuit terminals Main circuit output terminals Ground terminal Arrangement of Control Circuit Terminals Note: This illustration shows the terminal block with the front cover removed. Main Circuit Terminals Symbol R/L1 S/L2 T/L3 U/T1 V/T2 W/T3 +1 +2 ­ Connection terminals +1 and +2: DC reactor connection terminals +1 and ­: DC power supply input terminals Ground terminal Be sure to ground the terminal under the following conditions. Connect to a neutral point on the power supply to conform to EC Directives. Note Be sure to connect the ground terminal directly to the motor frame ground. Motor output terminals Name Power supply input terminals Description 3G3JV-A2j: 3-phase 200 to 230 V AC 3G3JV-ABj: Single-phase 200 t 240 V AC 3G3JV ABj Si l h to 3G3JV-A4j: 3-phase 380 to 460 V AC Note Connect single-phase input to terminals R/L1 and S/L2. 3G3JV-A2j: 3 phase 200 to 230 V AC 3G3JV A2j: 3-phase 3G3JV-ABj: 3-phase 200 to 240 V AC 3G3JV-A4j: 3-phase 380 to 460 V AC The maximum output voltage corresponds to the input power supply voltage for the Inverter. Connect the DC reactor for suppressing harmonics to terminals +1 and +2. When driving the Inverter with DC power, input the DC power to terminals +1 and ­. (Terminal +1 is a positive terminal. ) Note 25 Specifications Control Circuit Terminals Symbol Input p S1 S2 S3 S4 S5 SC FS FR FC Output MA MB MC AM AC Name Forward/Stop Multi-function input 1 (S2) Multi-function input 2 (S3) Multi-function input 3 (S4) Multi-function input 4 (S5) Sequence input common Frequency reference power supply Frequency reference input Frequency reference common Multi-function contact output (Normally open) Multi-function contact output (Normally closed) Multi-function contact output common Analog monitor output Analog monitor output common Function Forward at ON. Set by parameter n36 (Reverse/Stop) Set by parameter n37 (Fault reset) Set by parameter n38 (External fault: Normally open) Set by parameter n39 (Multistep reference 1) Common for S1 through S5 DC power supply for frequency reference use Input terminal for frequency reference use Common for frequency reference use Set by parameter n40 (during u g) running) Signal level Photocoupler p 8 mA at 24 V DC ( A (see note 2) 20 mA at 12 V DC 0 to 10 V DC (Input impedance = 20 k) ( pu peda ce 0 ) Relay output a at C 1 A max. at 250 V AC C Common for MA and MB use Set by parameter n44 (Output frequency) Common for AM use 2 mA max. The input method is set to NPN by default, so use the GND common for wiring. When a power supply is used and a common on the plus side is used for wiring, set SW7 to PNP and use a 24-V DC (±10%) power supply. 26 Dimensions Dimensions 3G3JV-A2001 to 3G3JV-A2007 (0. 1 to 0. 75 kW) 3-phase 200-V AC Input 3G3JV-AB001 to 3G3JV-AB004 (0. 1 to 0. 4 kW) Single-phase 200-V AC Input 3G3JV-A2015 to 3G3JV-A2022 (1. 5 to 2. 2 kW) 3-phase 200-V AC Input 3G3JV-AB007 to 3G3JV-AB015 (0. 75 to 1. 5 kW) Single-phase 200-V AC Input 3G3JV-A4002 to 3G3JV-A4022 (0. 2 to 2. 2 kW) 3-phase 400-V AC Input Two, 5-dia. holes t Rated voltage Model 3G3JV3G3JV A2001 A2002 A2004 A2007 Dimensions (mm) D t 3 3 5 5 3 3 5 70 70 102 122 70 70 112 Weight (kg) Rated voltage Model 3G3JV3G3JV A2015 A2022 AB007 AB015 A4002 A4004 A4007 A4015 A4022 Dimensions (mm) D 129 154 129 154 81 99 129 154 154 Weight (kg) 3-phase 200 V AC p Approx. 0. 9 3-phase 200 V AC p Single-phase 200 V AC gp 3-phase 400 V AC p Approx. 1. 5 Single-phase 200 V AC gp AB001 AB002 AB004 3G3JV-A2037 (3. 7 kW) 3-phase 200-V AC Input 3G3JV-A4037 (3. 7 kW) 3-phase 400-V AC Input Rated voltage Model 3G3JV3G3JV A2037 A4037 Dimensions (mm) D 161 161 Weight (kg) 3-phase 200 V AC 3-phase 400 V AC Approx. [. . . ] This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products. · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON 3G3JV




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON 3G3JV will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.