User manual OMRON 2D CODE READER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual OMRON 2D CODE READER. We hope that this OMRON 2D CODE READER user guide will be useful to you.


OMRON 2D CODE READER : Download the complete user guide (4178 Ko)

Manual abstract: user guide OMRON 2D CODE READER

Detailed instructions for use are in the User's Guide.

[. . . ] Z242-E1-03 V400-F050/250/350 2D Code Reader USER'S MANUAL Introduction Introduction ëÊ 1 èÕ ëÊ 2 èÕ ëÊ 3 èÕ ëÊ 4 èÕ ÇÕǹÇ?Ç Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Appendix Introduction Application Considerations (Read and understand this information first. ) Section 1 Studying the V400-F Section 2 Changing Reading Conditions Section 3 Setting RS-232C and Discrete I/O Communication Conditions Section 4 Other Settings Section 5 Communicating with PC and Programmable Controller Section 6 Troubleshooting Appendix 2D Code Reader User's Manual V400-F050/250/350 Introduction Introduction READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] Save the settings. Select [Save] from [Setting Menu] to save the changes you have made. p. 56 V400-F050/250/350 User's Manual 39 Section 2 Changing Reading Conditions Deleting the Content of a Bank This section explains how to delete the content of a bank and restore the default settings for that bank. 1. Switch to the setting mode. Hold down the center button for more than two seconds to activate the setting mode. Section 2 Deleting the Content of a Bank STILL/LIVE MODE UP TRIG EXECUTE DOWN "Changing Settings" p. 24 Hold down for more than two seconds. 2. Select [Bank Setting] from [Setting Menu]. The [Bank Setting] screen will appear. 3. From [Bank #00] to [Bank #09], select the bank whose content is to be deleted. The contents of the selected bank are displayed in the right area of the screen. The edit menu will be displayed. 4. If you select [Cancel], the operation menu will reappear without deletion. The content of the selected bank will be deleted, and the default settings will be restored for that bank. 6. Save the settings. Select [Save] from [Setting Menu] to save the settings. p. 56 40 V400-F050/250/350 User's Manual Section 2 Changing Reading Conditions Setting the Retry Method This section explains how to set the retry method (to execute reading and then capture an image twice or more). Two retry methods are available: "Same bank" and "Bank Switching". Item Same bank Exposure time change retry (Exposure) Details Capture is performed for the same bank by changing the exposure time in steps. p. 36 Section 2 Setting the Retry Method Simple retry (Normal) Capture is performed the specified number of times for the same bank. p. 36 Automatic bank switch retry (Bank Switching) Capture is performed continuously by switching from one bank to another. Setting the Bank Switching Retry Function 1. Switch to the setting mode. Hold down the center button for more than two seconds to activate the setting mode. STILL/LIVE MODE UP TRIG EXECUTE DOWN "Changing Settings" p. 24 Hold down for more than two seconds. 2. If you select [Cancel], the operation menu will reappear without reflecting the settings. V400-F050/250/350 User's Manual 41 Section 2 Changing Reading Conditions 5. Save the settings. Select [Save] from [Setting Menu] to save the settings. p. 56 Setting item Switch Function Settings OFF*/ON 1st Bank: #00 to #09 (*#00) Other: #00 to #09, None* Details If [ON] is selected, the bank will be switched from one to another as specified. No reading condition will be selected if [None] is selected. Section 2 Setting the Retry Method 1st Bank 2nd Bank 3rd Bank 4th Bank 5th Bank Total Timeout Switch Order 1000 to 9999 (9999*) Set the time at which reading is to be stopped following start of bank switch retry in case of reading failure. Auto* Fixed The switching order is determined automatically based on the frequency of use. Banks will be switched in the order they have been registered, starting from [1st Bank]. 42 V400-F050/250/350 User's Manual Section 3 Setting RS-232C and Discrete I/O Communication Conditions This section explains how to set RS-232C and discrete I/O communication conditions. Section 3 Setting RS-232C and Discrete I/O Communication Conditions Setting RS-232C Communication Conditions Setting Communication Conditions Setting the Data Format Setting Discrete I/O Communication Conditions 44 44 46 48 V400-F050/250/350 User's Manual 43 Section 3 Setting RS-232C and Discrete I/O Communication Conditions Setting RS-232C Communication Conditions This section explains how to set RS-232C communication conditions and data format. Setting Communication Conditions Set RS-232C communication conditions as follows. 1. Switch to the setting mode. Hold down the center button for more than two seconds to activate the setting mode. STILL/LIVE MODE UP TRIG Section 3 Setting RS-232C Communication Conditions EXECUTE DOWN "Changing Settings" p. 24 Hold down for more than two seconds. 2. Select [System Setting] [RS-232C] from [Setting Menu]. The RS-232C setting menu will appear. 3. Confirm the changes. Select [OK] to confirm the changes made to the [RS232C] settings. [. . . ] 14 × 18 mm 44 2, M 2D t ep h 5 8 1000 V AC (1 minute) 0. 25 mA max. Power line: 2 kVp-p; Pulse width: 50 ns; Rise time: 5 ns Burst continuation time: 15 ms; Period: 300 ms CE. . . EN61326: 1997, +A1: 1998+A2: 2001 (EMI: Class A) 10 to 150 Hz at a single-amplitude of 0. 35 mm (maximum acceleration: 50 m2/s), 10 times for 8 minutes each in 3 directions 150 m/2; 3 times each in 6 directions 0 to +45 °C -25 to +65 °C 25% to 85% RH (with no icing or condensation) No corrosive gases Mount the reader with four M3 screws or fixture (supplied with the reader). 31 × 42 mm Red LED Appendix Specifications and Dimensions V400-F050/250/350 User's Manual 95 Appendix Communication Cable V400-W23/23P/24/24P (Unit: mm) 39. 8 L (Note 1) 20 12-pin round connector 50 500 50 Ø15. 5. Vinyl insulated round cord Ø6. 8, 12 cores Nameplate D-sub 9-pin connector Note 1: The cable length (L1) must be as follows. Length L General specifications Model I/F connector Power supply wire I/O type V400-W23/P D-sub 9-pin connector (male) PLC connection type V400-W24/P D-sub 9-pin connector (female) DOS/V PC connection type Brown: +24V, Blue: GND V400-W23, V400-W24: NPN V400-W23P, V400-W24P: PNP 0 to +50 °C -25 to +65 °C 25% to 85% RH (with no icing or condensation) No corrosive gases Cable sheath: Heat-resistant vinyl chloride Special connector: PPS, PBT, POM D-sub connector: ABS 42 mm Ferrite core (×1) Appendix Specifications and Dimensions Operating ambient temperature Storage ambient temperature Ambient humidity Ambient environment Materials Minimum bending radius Accessories 96 V400-F050/250/350 User's Manual Appendix Monitor cable V400-WM0 (Unit: mm) 12-pin round connector L (See note 1. ) RAC Jack Ø12. 2 Ø15. 5. (See note 2. ) Vinyl insulated round cord Ø6. 5, 3 cores Nameplate Note 1: The cable length (L1) must be as follows. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON 2D CODE READER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON 2D CODE READER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.