User manual NILFISK APC 328

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NILFISK APC 328. We hope that this NILFISK APC 328 user guide will be useful to you.


NILFISK APC 328 : Download the complete user guide (854 Ko)

You may also download the following manuals related to this product:

   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 (1396 ko)
   NILFISK APC 328 7-10 (1000 ko)
   NILFISK APC 328 BROCHURE (561 ko)

Manual abstract: user guide NILFISK APC 328

Detailed instructions for use are in the User's Guide.

[. . . ] · Unplug the machine from the power outlet before cleaning or servicing. · Inspect the power cord regularly for damage, such as cracking, ageing, or damaged insulation. Replace the power cord with the same type as original if any damage is found. · If the machine is not working as it should, has been dropped, damaged, left outdoors or flooded with water, return it to a service center. [. . . ] Refer to the mainenance schedule on page 9. PARTS AND SERVICE: Repairs, when required, should be performed by your authorized distributor who maintains an inventory of original replacement parts and accessories. Call the distributor from whom you purchased this machine if you need parts and service. Have your serial number at hand. Serial Number: __________________ Model: APC 328 Purchase Date:_____________ Write the name and phone number of your distributor: _____________________________________ _____________________________________ (and be sure to register your purchase to active your warranty) YOUR MACHINE Operator Handle (1): Operator holds onto this handle to move the machine from one location to another. The solution fill hose is tethered to the lid, and hangs inside the arm of the Operator Handle. Maid's tote and Recovery tank lid (3): This removable container holds often-used items and has a handle for easy carrying. The recovery tank lid sits under the maid's tote and covers the opening in the Recovery Tank. This is where the operator can access the tank to clean it and the ball float cage. The tank can be flushed out by running clean warm water into this opening and laying the open drain hose into a bucket or drain. Spray Hose (5): This hose delivers water from the machine to the cleaning tool. NOTE: hold the end of the hose above the water level in the tank to avoid sudden, uncontrolled flow of waste water when you remove the cap, then lower the hose slowly to control the rate of discharge. Castors and Wheels (8): Castors pivot for ease of steering, and large back wheels make it easy to roll the machine from location to location. Chemical Feed Lines (9): These clear tubes connect the cleaning chemical containers to the machine where the chemical can be siphoned into the outlet water from the pump. Metering tips -- used to change the ratio of water to chemical -- are installed here. Switch Plate (10): The machine's on/off switches for the vacuum and for the pump are located here and this is where the valve to change chemical feeds is located. power cord connects to a power cord pigtail on the rear of the machine. Chemical Container Holders (12): Two molded-in bottle holders for chemical jugs. 11 2 1 4 3 9 5 12 6 10 7 8 KNOW YOUR SWITCH PLATE 1 I O 2 O 4 3 Vacuum Switch (1): turns on the vacuum motor. When the selector is pointed straight down, the valve is off and neither chemical is selected. When the selector is pointed directly towards one or the other symbols, that chemical is selected. Quick Connect (4): this is where solution comes out of the machine and the attachment point for the solution hose. METERING TIPS The chemical metering tips allow you to select the ratio of chemical to water, as the water flows out of the machine. Insert the correct metering tip for the desired mixture into the chemical siphon tube. COLOR Orange Pink Dark Green Yellow Light Blue Burgandy Black METERING TIPS HOLE SIZE MIX RATION 0. 007 0. 012 0. 014 0. 016 0. 020 0. 022 0. 048 1 to 128 1 to 64 1 to 50 1 to 32 1 to 20 1 to 15 1 to 5 FLOW RATE 7, 81 ml per 1 l 19, 53 ml per 1 l 23, 44 ml per 1 l 39, 06 ml per 1 l 46, 87 ml per 1 l 70, 33 ml per 1 l 156, 27 ml per 1 l SET-UP AND USE 1) Insert the appropriate metering tips into the chemical feed lines (see illustration, page 5). [. . . ] 15) Connect the vacuum hose, attach the squeegee, and turn on the vacuum (rocker switch). 16) Squeegee off the mirrors, pick up the liquid off the floor with the floor tool. NOTE: Keep the top of the drain hose higher than the water level in the tank to avoid uncontrolled discharge of water when you open the cap on the hose. CAUTION To avoid vacuum motor damage, always use a defoamer any time foam is present. Before you turn on the vacuum always make sure the filter screen on the ball float is clean and that the ball can travel freely. RE-PRIMING THE PUMP If the pump looses prime between jobs, follow the instructions to PRIME THE PUMP, above. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NILFISK APC 328




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NILFISK APC 328 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.