User manual NEVE 1081

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NEVE 1081. We hope that this NEVE 1081 user guide will be useful to you.


NEVE 1081 : Download the complete user guide (7681 Ko)

Manual abstract: user guide NEVE 1081

Detailed instructions for use are in the User's Guide.

[. . . ] 1081 Channel Amplifier Including 3U and 7U Rack Options User Guide 527-230 Issue 3 © 2000 AMS Neve plc own the copyright of all information and drawings contained in this manual which are not to be copied or reproduced by any means or disclosed in part or whole to any third party without written permission. HEAD OFFICE AMS NEVE PLC BILLINGTON ROAD BURNLEY LANCS BB11 5UB ENGLAND As part of our policy of continual product improvement, we reserve the right to alter specifications without notice but with due regard to all current legislation. TELEPHONE: +44 (0) 1282 457011 FAX: +44 (0) 1282 417282 LO N D O N OFFICE TELEPHONE: +44 (0) 20 7916 2828 FAX: +44 (0) 20 7916 2827 NORTH AMERICAN OFFICES AMS NEVE INC. , NEW YORK Disclaimer: The information in this manual has been carefully checked and is believed to be accurate at the time of publication. However, no responsibilty is taken by us for inaccuracies, errors or omissions nor any liability assumed for any loss or damage resulting either directly or indirectly from use of the information contained within it. TEL: +1 (212) 965 1400 FAX: +1 (212) 965 3739 AMS NEVE INC. , HOLLYWOOD TEL: +1 (818) 753 8789 FAX: +1 (818) 623 4839 RUPERT NEVE CANADA INC. , TORONTO TEL: +1 (416) 365 3363 FAX: +1 (416) 365 1044 e-mail: enquiry@ams-neve. com http://www. ams-neve. com 1081 Channel Amplifier Contents Introduction Installation Dimensions Power Requirements Phantom Power Output Level Control Amplifier Controls EMI Filter Components Rear Panel Views Connector Details Connector Details Continued Specifications Service Information 1081 Recall Sheet - Horizontal Module 1081 Recall Sheet - Vertical Module 1 1 2 3 4 4 5 6 7 8 9 10 11 12 13 User Guide Issue 3 Page i 1081 Channel Amplifier Introduction Introduction The 1081 channel amplifier was first produced in 1972 to provide the mic/line-amp and EQ sections in Neve consoles such as the 8048. [. . . ] Negative Earth Mains Supply (rack units) The power supply unit is a universal input type therefore no mains operating voltage setting is required. The mains switch on the front panel of the 3U and 7U rack units is non-illuminating. The CH (chassis) and 0V Link should be connected or instability may result. User Guide Issue 3 Page 3 1081 Channel Amplifier Phantom Power Mains Fuse (rack units) The mains fuse is located in the IEC mains input connector on the rear of the 3U and 7U rack units. Secondary Protection Fuses (rack units) Secondary protection fuses for the 24V and 48V supplies are located behind the front panel on the power supply filter PCB SZN825-058 in both 3U and 7U rack units. DC Power Supply Indicators (rack units) The red LED on the front panel of both 3U and 7U rack units indicates +24V power healthy when illuminated. The green LED on the front panel of both 3U and 7U rack units indicates +48V power healthy when illuminated. Phantom Power Phantom power can be supplied to each module by pressing the phantom power switch on the front panel of the 3U or 7U rack. The LED in the switch will illuminate confirming that phantom power is supplied. Output Level Control Each channel has an independent Output Level Control. This control allows the input and EQ to operate at a higher level and then for the signal to be returned to a normal operating level at the output. The output is 10dB down with the control in the mid-position. User Guide Issue 3 Page 4 1081 Channel Amplifier Amplifier Controls Amplifier Controls dB 70 60 80 20 10 0 +10 H. F. Controls: LINE 50 40 MIC 5 switched frequencies, shelving or peaking curve, continuously variable 18dB cut or boost. 10 switched frequencies with continuously variable 18dB cut or boost, high or low Q selection. 10 switched frequencies with continuously variable 18dB cut or boost, high or low Q selection. [. . . ] The use of screened cables and connectors is recommended for all connections. Output noise better than - 80dBm at all line input levels. Distortion: Frequency Response: Noise: User Guide Issue 3 Page 10 1081 Channel Amplifier Service Information Service Information Schematic Drawing index PL31081- Channel Amplifier Horizontal and Vertical module versions: PL31081-C PL10306-C PL10312-C PL10338-C PL10340-C PL20046 PL20047 PL20048/4 PL20048/5 PL20049 PL20050 Channel Amplifier Dual Voltage Follower Channel Amplifier Motherboard High Gain Amplifier Output Amplifier Sensitivity Switch Treble Switch Assembly Upper Presence Switch Assembly Lower Presence Switch Assembly LP/HP Filter Switch Assembly Bass Switch Assembly AM3631 - 3U Rack: AM3631 SZN825-058 SSN818-036 SUN870-081 SYN824-128 NN3726 2 CH 1081 Mainframe Assembly Detail PSU Filter PCB 0V Stud Filter PCB 2CH I/P O/P Backplane 2 Switch Phantom Power PCB Chassis Cable Assy AM3630 - 7U Rack: AM3630 SZN825A058 8 CH 1081 Mainframe Assembly Detail PSU Filter PCB Same as the 3U Rack User Guide Issue 3 Page 11 1081 Channel Amplifier 1081 Recall Sheet - Horizontal Module 1081 Recall Sheet - Horizontal Module User Guide Issue 3 Page 12 1081 Channel Amplifier 1081 Recall Sheet - Vertical Module 1081 Recall Sheet - Vertical Module User Guide Issue 3 Page 13 Title: 2 Channel 1081 Chassis Wiring CABLE Code 310-166 310-183 310-183 310-132 310-132 310-132 310-166 310-074 310-072 310-048 310-046 310-075 310-072 310-074 310-072 310-072 310-048 310-046 310-033 310-033 Schedule Nr: AM3631 Issue: 3 TO:Comment Pin Stud Stud Stud 13 23 14 24 L N Stud 1 2 X2 X1 3 4 FROM:Colour Green/Yellow Green/Yellow Green/Yellow Brown Blue Brown Blue Brown Blue Green/Yellow Red Black Red Black Orange Black Red Black Black Red Black Green Green E1 E2 ROUTING Connector 330-119 330-069 330-069 330-119 330-119 330-471(1of2) 330-471(1of2) 330-471(2of2) 330-471(2of2) 330-069 330-069(1of2) 330-069(1of2) 330-069(2of2) 330-069(2of2) 330-069 330-069 420-712 Type 32/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 32/0. 2 24/0. 2 24/0. 2 16/0. 2 16/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 16/0. 2 16/0. 2 7/0. 2 7/0. 2 Pin E E E L N L N L N Ch +24V -0V +24V -0V + 1 2 J1 Location IEC PSU1 PSU2 IEC IEC PSU1 PSU1 PSU1 PSU1 SSN818A036 PSU1 PSU1 PSU1 PSU1 PSU2 PSU2 CN2 SZN825-058 SSN818A036 1081CN PNL 1081CN PNL SUN870-081 Channel 1&2 Signal Length Connector 330-454 330-454 330-454 Location Chassis Safety Chassis Chassis Switch Switch Switch Switch PSU2 PSU2 Chassis CN1 SZN825-058 Switch Switch CN1 SZN825-058 1081CN PNL Twist together Twist together Twist together Twist together 330-069 330-069 330-454 420-712 +24V WA17103 0VA WA17103 2cm 2cm U U E E Chassis Chassis +24V WA17103 0VA WA17103 0VA WA17103 1081 CN1 1081 CN2 1081 CN1 1081 CN2 330-006 330-006 13 December, 2001 Page: 3 Title: 8 Channel 1081 Chassis Wiring CABLE Code 310-166 310-183 310-183 310-132 310-132 310-132 310-166 310-074 310-072 310-048 310-046 310-075 310-072 310-074 310-072 310-072 310-048 310-046 310-033 310-033 310-033 Schedule Nr: AM3630 Issue: 4 TO:Comment Pin Stud Stud Stud 13 23 14 24 L N Stud 1 2 X2 X1 3 4 FROM:Colour Green/Yellow Green/Yellow Green/Yellow Brown Blue Brown Blue Brown Blue Green/Yellow Red Black Red Black Orange Black Red Black Black Red Black Green Green Green E1 E2 E1 ROUTING Connector 330-119 330-069 330-069 330-119 330-119 330-471(1of2) 330-471(1of2) 330-471(2of2) 330-471(2of2) 330-069 330-069(1of2) 330-069(1of2) 330-069(2of2) 330-069(2of2) 330-069 330-069 420-712 Type 32/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 32/0. 2 24/0. 2 24/0. 2 16/0. 2 16/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 24/0. 2 16/0. 2 16/0. 2 7/0. 2 7/0. 2 7/0. 2 Pin E E E L N L N L N Ch +24V - 0V +24V -0V +48V - 0V 1 2 J1 Location IEC PSU1 PSU2 IEC IEC PSU1 PSU1 PSU1 PSU1 SSN818A036 PSU1 PSU1 PSU1 PSU1 PSU2 PSU2 CN2 SZN825-058 SSN818A036 1081CN PNL 1081CN PNL SUN870-081 Channel 1&2 SUN870-081 Signal Length 25cms 40cms 40cms 58cms 58cms 80cms 80cms 15cms 15cms 23cms 90cms 90cms 90cms 90cms 1mtr 1mtr 80cms 82cms 58cms 8cms 8cms 8cms 8cms 2cm 2cm 2cm Connector 330-454 330-454 330-454 Location Chassis Safety Chassis Chassis Switch Switch Switch Switch PSU2 PSU2 Chassis CN1 SZN825-058 Switch Switch CN1 SZN825-058 1081CN PNL Twist together Twist together Twist together Twist together 330-069 330-069 330-454 420-712 +24V WA17103 0VA WA17103 U U E E Chassis Chassis Chassis +24V WA17103 0VA WA17103 0VA WA17103 1081 CN1-4 1081 CN5-8 1081 CN1-4 1081 CN5-8 330-006 330-006 330-006 13 December, 2001 Page: 3 Title: 8 Channel 1081 Chassis Wiring CABLE Code 310-033 310-033 Schedule Nr: AM3630 Issue: 2 TO:Comment Pin Chassis Chassis FROM:Colour Green Green ROUTING Connector Location Channel 3&4 SUN870-081 Type 7/0. 2 7/0. 2 Pin E2 E1 Signal Length 2cm 2cm Connector 330-006 330-006 Location 310-033 310-033 310-033 7/0. 2 7/0. 2 7/0. 2 Green Green Green E2 E1 E2 Channel 5&6 SUN870-081 Channel 7&8 2cm 2cm 2cm Chassis Chassis Chassis 330-006 330-006 330-006 13 December, 2001 Page: 4 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NEVE 1081




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NEVE 1081 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.