User manual NETGEAR FSM726

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NETGEAR FSM726. We hope that this NETGEAR FSM726 user guide will be useful to you.


NETGEAR FSM726 : Download the complete user guide (5673 Ko)

Manual abstract: user guide NETGEAR FSM726

Detailed instructions for use are in the User's Guide.

[. . . ] All rights reserved. Trademarks NETGEAR® is a registered trademark of NETGEAR, Inc. All other trademarks and registered trademarks are the property of their respective owners. Statement of Conditions In the interest of improving internal design, operational function, and/or reliability, NETGEAR reserves the right to make changes to the products described in this document without notice. NETGEAR does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein. Certificate of the Manufacturer/Importer It is hereby certified that the NETGEAR Model FSM726 Managed Switch has been suppressed in accordance with the conditions set out in the BMPT-AmtsblVfg 243/1991 and Vfg 46/1992. The operation of some equipment (for example, test transmitters) in accordance with the regulations may, however, be subject to certain restrictions. Federal Office for Telecommunications Approvals has been notified of the placing of this equipment on the market and has been granted the right to test the series for compliance with the regulations. Voluntary Control Council for Interference (VCCI) Statement This equipment is in the first category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council for Interference by Data Processing Equipment and Electronic Office Machines that are aimed at preventing radio interference in commercial and/or industrial areas. [. . . ] It also lets you manage the switch using a directly connected VT-100 terminal, personal computer (PC), Apple Macintosh, or UNIX workstation. The terminal, computer, or workstation connects to the console port using the null-modem cable supplied with your switch. The console port is configured to use the following settings: · Baud rate: 9, 600 bps · Data bits: 8 · Parity: none · Stop bit: 1 · Flow control: none These settings appear below the connector on the switch front panel. In addition to using the console port, you can manage the switch using a Web browser or a Simple Network Management Protocol (SNMP) management program. Note: You must use the console port for the initial management configuration. Page 11 of 23 For more information about console-port connections, see "Connecting to the Console Port" in Chapter 3 Installation. For more information about managing the switch, see the User Manual located on the CDROM. Page 12 of 23 CHAPTER 3: INSTALLATION This chapter describes the installation procedures for your NETGEAR Model FSM726 Managed Switch. Switch installation involves the following steps: Step 1: Preparing the site Step 2: Installing the switch Step 3: Checking the installation Step 4: Applying AC power Step 5: Connecting devices to the switch Step 6: Installing a GBIC module Step 7: Connecting to the console port to manage the switch (initial configuration) Step 1: Preparing the Site Before you install your switch, be sure your operating environment meets the operating environment requirements in Table 3-1. Site Requirements Characteristics Mounting Desktop installations: Rack-mount installations: Requirements Provide a flat table or shelf surface. Use a 19-inch (48. 3-centimeter) EIA standard equipment rack that is grounded and physically secure. Locate the switch in a position that lets you access the front panel RJ-45 ports, view the front panel LEDs, and access the rear-panel power connector. Provide a power source within 6 feet (1. 8 meters) of the installation location. Be sure the AC outlet is not controlled by a wall switch, which can accidentally turn off power to the outlet and the switch. Install the switch in a dry area, with ambient temperature between 0 and 40ºC (32 and 104ºF). Keep the switch away from heat sources such as direct sunlight, warm air exhausts, hot-air vents, and heaters. The installation location should have a maximum relative humidity of 90%, non-condensing. Do not restrict airflow by covering or obstructing air inlets on the sides of the switch. Keep at least 2 inches (5. 08 centimeters) free on all sides for cooling. Be sure there is adequate airflow in the room or wiring closet where you intend to install the switch. Keep the switch at least 6 ft (1. 83 m) away from nearest source of electromagnetic noise, such as a photocopy machine. Access Power source Environmental Temperature: Operating humidity: Ventilation: Operating conditions: Page 13 of 23 Step 2: Installing the Switch You can install your NETGEAR Model FSM726 Managed Switch on a flat surface or in a standard 19-inch rack. Installing the Switch on a Flat Surface The switch ships with four self-adhesive rubber footpads. Stick one rubber footpad on each of the four concave spaces on the bottom of the switch. Installing the Switch in a Rack To install the switch in a rack, use the following procedure (and refer to Figure 3-1). [. . . ] Select `D' for reset, and confirm with a `Y' To continue using the console interface to manage your switch, e. g. Use your arrow keys to move the curser down to port 25 or 26, and hit the space bar to toggle between the RJ-45 port and the GBIC port. To learn more about the managed features on your switch, refer to the User Manual on the GearBox for Managed Switches CD-ROM. Page 18 of 23 APPENDIX A: TECHNICAL SPECIFICATIONS This appendix provides technical specifications for the NETGEAR Model FSM726 Managed Switch. Network Protocol and Standards Compatibility IEEE 802. 3 10BASE-T IEEE 802. 3u 100BASE-TX IEEE 802. 3z 1000BASE-SX IEEE 802. 3ab 1000BASE-T IEEE 802. 3x flow control Management IEEE 802. 1Q Static VLAN (Up to 64) IEEE 802. 1p Class of Service (CoS) IEEE 802. 1D Spanning Tree Protocol Port Trunking - Manual as per IEEE802. 3ad Link Aggregation IGMP v1, v2 Snooping Support Port Mirroring support SNMP v1 RFC1757 RMON 1 groups 1, 2, 3, and 9 RFC1213 MIB II RFC1643 Ethernet Interface MIB RFC1493 Bridge MIB RFC2131 DHCP client (& BootP) RFC2138 RADIUS client Broadcast storm control Private Enterprise MIB Configuration file upload, download (TFTP) Interface 26 RJ-45 connectors for 10BASE-T, 100BASE-TX, and 1000BASE-T (Auto UplinkTM on all ports) 2 Gigabit Interface Converter (GBIC) slots for GBIC modules RS-232 Console Port LEDs Per port (10/100 and Gigabit): Link, Speed, Duplex, Activity, and Collision Per device: Power Performance Specifications Forwarding modes: Store-and-forward Bandwidth: 12. 8 Gbps (Non-blocking) Network latency: Less than 80 microseconds for 64-byte frames in store-and-forward mode for10 Mbps to 100 Mbps transmission Address database size: 8, 000 media access control (MAC) addresses per system Addressing: 48-bit MAC address 10/100 buffer memory: 735 KB embedded memory for 24 ports Gigabit buffer memory: 122 KB embedded memory per port Acoustic noise: (ANSI-S10. 12): 45 dB Heat Dissipation: 18. 99 Btu/hr Page 19 of 23 Mean Time Between Failure (MTBF): 58, 300 hours (~ 6. 5 years) Power Supply Power Consumption: 36 W maximum 100-240VAC/50-60 Hz universal input Physical Dimensions 440 x 253 x 43 mm (W x D x H) 17. 32 x 9. 96 x 1. 7 inch Environmental Specifications Operating temperature: 0 to 40°C Storage temperature: -20 to 70°C Operating humidity: 90% maximum relative humidity, non-condensing Storage humidity: 95% maximum relative humidity, non-condensing Operating altitude: 10, 000 ft (3, 000 m) maximum Storage altitude: 10, 000 ft (3, 000 m) maximum Electromagnetic Emissions CE mark, commercial FCC Part 15 Class A VCCI Class A EN 55022 (CISPR 22), Class A C-Tick Electromagnetic Immunity EN 50082-1 EN 55024 Safety CE mark, commercial CSA certified (CSA 22. 2 #950) TUV licensed (EN 60 950) UL listed (UL 1950)/cUL IEC950/EN60950 Modules AGM721F GBIC SX module for 1000BASE-SX connections with SC connectors for 50um or 62. 5um multimode fiber cable Page 20 of 23 APPENDIX B: TROUBLESHOOTING This chapter provides information about troubleshooting the NETGEAR Model FSM726 Managed Switch. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NETGEAR FSM726




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NETGEAR FSM726 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.