User manual NETGEAR DS516 INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NETGEAR DS516. We hope that this NETGEAR DS516 user guide will be useful to you.


NETGEAR DS516 INSTALL GUIDE: Download the complete user guide (644 Ko)

Manual abstract: user guide NETGEAR DS516INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] Users connected at 10 Mbps can coexist with power users connected at 100 Mbps; both types of users can take advantage of shared resources connected at the higher transmission speed. The following illustration shows some typical applications of the three hub models in a mixed 10/100 Mbps environment. ISDN Printer Auto 10/100 Mbps DUAL Model DS524 hub SPEED 1 100 100 Mbps MODEL DS524 16PORT 10/100Mbps Dual Speed Stackable Hub Collision Utilization% 1 10 20 >40 10 Mbps 5 10 On=Link, Blinking=Receive 100 10 On=Link, Blinking=Receive 100 10 On=Link, Blinking=Receive 12 Normal/Uplink Power Data 13 17 24 Model DS508 hubs Model DS516 hub Model RT328 ISDN Router 100 Mbps 10 Mbps Servers PCs Power user 8673FA Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Product Illustrations Front Panel of the Model DS508 Hub Auto 10/100 Mbps DUAL SPEED 1 2 3 4 5 6 7 8 MODEL DS508 8PORT 10/100Mbps Dual Speed Stackable Hub Collision Power 1 Utilization% 100 Mbps 100M >40 10 Mbps 10M On=Link, Blinking=Receive 100 10 On=Link, Blinking=Receive Normal/Uplink 10 20 Front Panel of the Model DS516 Hub Auto 10/100 Mbps DUAL SPEED 1 8 100 100 Mbps MODEL DS516 16PORT 10/100Mbps Dual Speed Stackable Hub Power Collision Data 1 Utilization% 10 20 >40 10 Mbps 10 On=Link, Blinking=Receive 100 10 On=Link, Blinking=Receive Normal/Uplink 9 16 Front Panel of the Model DS524 Hub 100 Mbps Collision LED 100 Mbps Utilization LEDs vista RJ-45 network ports Auto 10/100 Mbps DUAL SPEED 1 100 10 On=Link, Blinking=Receive 5 100 10 On=Link, Blinking=Receive 100 10 On=Link, Blinking=Receive 12 MODEL DS524 16PORT 10/100Mbps Dual Speed Stackable Hub Collision Utilization% 100 Mbps Normal/Uplink Power Data 1 10 20 >40 10 Mbps 13 17 24 10 Mbps Utilization LEDs 10 Mbps Collision LED Power LED Normal/Uplink push button 8671FA Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Front-Panel LEDs The Model DS508, DS516, and DS524 hubs provide front-panel LEDs for monitoring individual ports and hub status. The following table describes the front-panel LEDs and their functions. Label Power Collision 10 Mbps 100 Mbps Utilization% 10 Mbps Green Blinking Indicates the amount of data traffic on the 10 Mbps segment. [. . . ] Front and back clearance for cables and wiring hardware such as punchdown blocks. Flat area approximately 13. 0 inches (33. 0 cm) by 8. 0 inches (20. 3 cm). Humidity Ventilation Operating conditions Service access Power Tabletop requirements Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Rack requirements Wiring hardware Standard 19-inch (48. 26 cm) EIA equipment rack, with supplied mounting bracket hardware; 1. 0 EIA rack-mount spaces needed for each hub. Wiring hardware, such as punchdown blocks or patch panels, should be complete before installing the hub. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Installation Procedures Install the Hub Install the Hub on a Flat Surface If installing the hub on a flat surface such as a tabletop, make sure the bottom of the chassis is clean and dry and allow at least 2 inches of space on all sides of the hub to ensure proper ventilation. Set the hub on a table or shelf so that it has at least 2 inches (5 cm) of space on all sides. Connect the power cord(s) first to the power entry receptacle on the hub rear panel and then to the wall. Install the Hub in a Rack To install the hub in a rack, make sure you have #2 and #3 Phillips screwdrivers. Refer to the illustration and follow the steps. #3 Phillips screwdriver (use large screws with spacers) #2 Phillips screwdriver (use small screws) 1 Power Data Collisi on Link RX 5 13 Link RX 17 Link RX 12 Norma l/Uplin k 24 8145FA 1. 2. Attach the mounting brackets (supplied in the rack mount kit) to the sides of the hub using the screws provided. Attach the hub (with the mounting brackets) to the rack using two panhead screws with nylon washers. Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide Build a Larger Network Cascade up to Eight Hubs to Build a Larger Network As many as eight Model DS508, Model DS516, or Model DS524 hubs can be cascaded for up to a maximum of 192 ports in a single repeater (or collision) domain. Any device connected to one of the 192 ports at either 10 or 100 Mbps can connect through the network to any other device attached to the cascade stack. The stack of eight hubs can consist of any combination of Model DS508, Model DS516, and Model DS524 hubs daisy-chained together using the supplied cascade cable. The LEDs in the following illustration appear as they would in an operational stack of hubs. Terminator LED On Cascade Up Cascade Down 10/100 Mbps Terminator Bridge 100-240 VAC 50-60 Hz 0. 5A Cascade Up Cascade Down 10/100 Mbps Terminator Bridge 100-240 VAC 50-60 Hz 0. 5A Cascade Up Cascade Down 10/100 Mbps Terminator Bridge 100-240 VAC 50-60 Hz 0. 5A Cascade Up Cascade Down 10/100 Mbps Terminator Bridge 100-240 VAC 50-60 Hz 0. 5A Bridge LED On Terminator LED On 8099FA The cascade connectors on the Model DS508, Model DS516, and Model DS524 hubs use a shared circuit. When power is supplied to one of the hubs in a stack, the Terminator LED in the top hub of the stack and the Terminator LED and 10/100 Mbps Bridge LED in the bottom hub of the stack will be on. If power is disconnected from the bottom hub in the stack, the hub above it takes over the bridge function. Computers and workstation adapter cards are usually media-dependent interface ports, referred to as MDI or Uplink ports. The figures illustrate the use of straight-through and crossover twisted pair cables. Straight-through twisted pair cable Uplink or MDI port 1 Tx 2 Normal or MDI-X port 1 Rx 2 3 Rx 6 3 Tx 6 Normal or MDI-X port 1 Rx 2 Crossover twisted pair cable Normal or MDI-X port 1 Rx 2 3 Tx 6 3 Tx 6 8146EB RJ-45 Connector The RJ-45 connector (shown in the illustration with an RJ-45 plug) is used to connect workstations, hubs, and switches through unshielded twisted pair cable. The RJ-45 connector accepts four-pair Category 3 or Category 5 UTP cable. 12345678 8 1 711EA Model DS508/DS516/DS524 Dual Speed Stackable Hub Installation Guide RJ-45 Connector Pin Assignment 1 2 3 6 4, 5, 7, 8 Normal Assignment on Ports 1­8, 1­16, or 1­24 Input Receive Data + Input Receive Data Output Transmit Data + Output Transmit Data Not used Uplink Assignment on Port 8, 16, or 24 Output Transmit Data + Output Transmit Data Input Receive Data + Input Receive Data Not used Troubleshooting Information Symptom Power LED off Cause No power at hub In a stack, no power at hub but Terminator LED is on Solution Check the power cord connections. In a stack, the termination circuitry gets power from the cascade cable. If one hub in the stack has a faulty power cord or the cord is unplugged, the Terminator LED remains on and the remaining hubs in the stack operate normally. Terminator LED of a Cascade cable not Check for proper connection. middle hub in a stack is on connected properly Link LED off or intermittent Port connection not functioning Check the crimp on the RJ-45 connectors and make sure that the plug is properly inserted and locked into the port at both the hub and device. Make sure cabling is Category 5 and meets the requirements for 100 Mbps operation. [. . . ] Consequently, when this equipment is used in a residential area or in an adjacent area thereto, radio interference may be caused to equipment such as radios and TV receivers. Federal Communications Commission (FCC) Compliance Notice: Radio Frequency Notice Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NETGEAR DS516




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NETGEAR DS516 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.