User manual NEFF D99M5NO

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NEFF D99M5NO. We hope that this NEFF D99M5NO user guide will be useful to you.


NEFF D99M5NO : Download the complete user guide (2389 Ko)

Manual abstract: user guide NEFF D99M5NO

Detailed instructions for use are in the User's Guide.

[. . . ] If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room. An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded. Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens. [. . . ] Important: Metal filters that are saturated with grease should not be washed together with other dishes etc. When cleaning the filters by hand, soak them in hot soapy water first of all. Then brush the filters clean, rinse them thoroughly and leave the water to drain off. Removing and inserting the metal grease filters: Warning: The halogen bulbs must be switched off and cool. Press the catch on the grease filters inwards and fold the filters down. 2. Press the 0 button. 19 Filters and maintenance Activated carbon filter: For neutralizing odours in recirculating mode. Caution: As the filter becomes more and more saturated with grease, there is an increased risk of fire and the function of the extractor hood may be impaired. Important: Change the activated carbon filter promptly to prevent the risk of fire from the accumulation of heat when deep-fat frying or roasting. Inserting the filter: Warning: The halogen bulbs must be switched off and cool. Remove the metal-mesh filters (see "Removing and inserting the metalmesh grease filters"). Saturation indicator: When the activated carbon filter reaches saturation point, an acoustic signal is sounded for 10 seconds after the fan has switched off, and a ã appears in the display. Note: If the light does not function, check that the bulbs have been inserted correctly. 21 Setting the saturation indicator If it becomes necessary to change the operating mode (exhaust-air/recirculating mode), the saturation indicator for the filters must also be altered (see Installation Instructions). If you encounter a problem If an # or ã appears in the display: See "Filters and maintenance" Section. If is not possible to operate the extractor hood: Disconnect the extractor hood from the mains electricity supply by pulling out the plug or switching it off at the main fuse box. If you have any questions or if a fault occurs, please call Customer Service. When you call, please quote the following: E-Nr. FD Enter the relevant numbers into the box above. (product no. ) and FD (production date) are shown on the nameplate which can be seen inside the extractor hood after the filter frame has been detached. 22 Installation Instructions: Important information Old appliances are not worthless rubbish. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner. Please ask your dealer or inquire at your local authority about current means of disposal. The extractor hood can be used in exhaust air or circulating air mode. Minimum distance between electric hob and bottom edge of extractor hood: 550 mm, Fig. The extractor hood must not be installed over a solid fuel cooker ­ a potential fire hazard (e. g. flying sparks) ­ unless the cooker features a closed, non-removable cover and all national regulations are observed. [. . . ] Appliances with a rear light: A recess panel or tiles fitted to the wall directly under the extractor hood must not project by more than 15 mm, otherwise the light cover may be damaged. Weight in kg: Exhaust air 70 cm 90 cm 20, 6 21, 7 Recirculating air 21, 1 22, 2 Electrical connection WARNING: THIS APPLIANCE MUST BE EARTHED IMPORTANT: Fitting a Different Plug: The wires in the mains lead are coloured in accordance with the following code: Green and Yellow ­ Earth Blue ­ Neutral Brown ­ Live If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals. Connect the green and yellow (Earth) wire to the terminal in the plug marked `E' or with the symbol ( ), or coloured green or green and yellow. Connect the blue (Neutral) wire to the terminal in the plug marked `N' or coloured black. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NEFF D99M5NO




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NEFF D99M5NO will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.