User manual NEC DSX-40 HARDWARE MANUAL
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NEC DSX-40. We hope that this NEC DSX-40 user guide will be useful to you.
You may also download the following manuals related to this product:
NEC DSX-40 QUICK START GUIDE (375 ko)
Manual abstract: user guide NEC DSX-40HARDWARE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] Empowered by Innovation
Components Installation Optional Equipment
Specifications and Parts
DSX-40 Hardware Manual
P/N 1093097
Rev 1, October 2006 Printed in U. S. A.
01. 01. 09
For additional resources, visit our Technical Support site on the web at http://www. necdsx. com.
This manual has been developed by NEC Unified Solutions, Inc. It is intended for the use of its customers and service personnel, and should be read in its entirety before attempting to install or program the system. Any comments or suggestions for improving this manual would be appreciated. 4 Forest Parkway Shelton, CT 06484 www. necunifiedsolutions. com
Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a warranty of, or representation with respect to, any of the equipment covered. [. . . ] Second 4 station ports in the middle position Built-in analog station ports. See Installing a DSX Analog Door Box on a BuiltIn Door Box Port (page 49). Four additional lines provided by the line expansion card installed in the bottom position.
2
STA 25-26 Door 1-2
3
CO 1-4 CO 5-8
28
Installation
DSX-40 Hardware Manual
Connecting Extensions and Lines
3
Line Block
Installation
DSX-40 Hardware Manual
10 93 09 7-8
Cable 1
1
2
Cable 2 Cable 3
Station Block
Station Block
Figure 8: Extension and Line Cabling
Installation
29
Connecting Extensions and Lines
Punch Down for Extensions
To punch down the cables for extensions: 1. For each 66M1-50 block, punch down the Installation Cable in standard color-code order.
Extensions 300-323 Shown
25-PAIR CABLE RJ61X BLOCK TERM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 COLOR CODE WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU BLU-BLK BLK-ORN ORN-BLK BLK-GRN GRN-BLK BLK-BRN BRN-BLK BLK-SLT SLT-BLK YEL-BLU BLU-YEL YEL-ORN ORN-YEL YEL-GRN GRN-YEL YEL-BRN BRN-YEL YEL-SLT SLT-YEL VIO-BLU BLU-VIO VIO-ORN ORN-VIO VIO-GRN GRN-VIO VIO-BRN BRN-VIO VIO-SLT SLT-VIO FUNCTION 300 300 301 301 302 302 303 303 304 304 305 305 306 306 307 307 308 308 309 309 310 310 311 311 312 312 313 313 314 314 315 315 316 316 317 317 318 318 319 319 320 320 321 321 322 322 323 323 NC NC T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R T R RJ61X 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8
To make your own cables, see Making Your Own Cables (page 33).
1
10 93 09 7-9
2
1 2 3 4 5 6
3
4
5
8
1
RJ61X Plug
6
Figure 9: Punch Down for Extensions
30
Installation
DSX-40 Hardware Manual
Connecting Extensions and Lines
Punch Down for Lines
To punch down the cable for lines: 1. For each 66M1-50 block, punch down the Installation Cable in standard color-code order.
Lines 1-8
To make your own cables, see Making Your Own Cables (page 33).
25-PAIR CABLE RJ61X BLOCK TERM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 COLOR CODE WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU BLU-BLK BLK-ORN ORN-BLK BLK-GRN GRN-BLK BLK-BRN BRN-BLK BLK-SLT SLT-BLK YEL-BLU BLU-YEL YEL-ORN ORN-YEL YEL-GRN GRN-YEL YEL-BRN BRN-YEL YEL-SLT SLT-YEL VIO-BLU BLU-VIO VIO-ORN ORN-VIO VIO-GRN GRN-VIO VIO-BRN BRN-VIO VIO-SLT SLT-VIO FUNCTION 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 T R T R T R T R T R T R T R T R RJ61X
Installation
1
10 93 09
5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8
DSX-40 Hardware Manual
7 - 10
2
NC
NC
1 2
NC
8
1
RJ61X Plug
Figure 10: Punch Down for Lines
Installation
31
Connecting Extensions and Lines
Securing the Cables
Securing the Ground Wires and Station Cables
After you have punched down your cables, route them down the side of the cabinet and secure them with the strain relief.
Figure 11: Securing the Cables
Securing the AC Power Cord
Snap in the provided power cord strain relief and install the cord as shown below.
Figure 12: Installing the AC Power Cord and Strain Relief
32
Installation
1093097 - 11
10930 97 - 14
DSX-40 Hardware Manual
Connecting Extensions and Lines
Making Your Own Cables
Making Your Own Installation Cables
The following products should help if you make your own cables. The connector is generally referred to as a RJ45 connector wired in an RJ61X configuration. Suttle SE-266-8K 8 Position Modular Plug (requires an SE-166 or SE-166-6 modular crimping tool). Hubbell BRFT4P Snap-On 8 Position Modular Plug (does not require a special crimping tool).
To 66 Block WHT-BLU (1T) To CPU Mod Jack RJ61X Pin 1 2 3 4 5 6 7 8
80000 - 18C
Installation
Port Designation 4T 3T 2T 1R 1T 2R 3R 4R
BLU-WHT (1R) WHT-ORN (2T) ORN-WHT (2R) WHT-GRN (3T) GRN-WHT (3R) WHT-BRN (4T)
Latch faces up
Note reversal
BRN-WHT (4R)
Figure 13: 8-Pin (RJ61X) Jack Pinouts
Connecting Extensions
A fully expanded DSX-40 can connect up to 26 extensions. The basic Main Equipment Cabinet provides 8 digital station ports and 2 analog station ports built in. The configuration of the remaining 16 station ports depends on the combination of 8-Port Digital Station and 8-Port Analog Station Cards installed. Using Figure 9: Punch Down for Extensions (page 30) as a guide, plug the installation cable plugs into the appropriate jacks on the Main Equipment Cabinet. Install a modular jack for each extension within 6 feet of the telephone's location. For each extension, run one-pair 24 AWG station cable from the station block to the modular jack. - To make adds, moves, and changes easier, be sure to leave a service loop in your station cable. Terminate the station cable WHT/BLU - BLU/WHT leads to the RED and GRN lugs in the modular jack. Install bridging clips as required.
DSX-40 Hardware Manual
Installation
33
Connecting Extensions and Lines
1093097 - 12
25-PAIR CABLE RJ61X BLOCK TERM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 COLOR CODE WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU FUNCTION 300 300 301 301 302 302 303 303 304 304 305 305 306 306 307 307 308 308 309 309 310 T R T R T R T R T R T R T R T R T R T R T RJ61X 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2
ESIU ESIU
YEL YEL BLU-WHT BLK WHT-BLU RED RED GRN GRN BLU-WHT BLK WHT-BLU
1
2
625 Modular Jack
625 Modular Jack
3
Station Block 1
25-PAIR CABLE RJ61X BLOCK TERM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 COLOR CODE WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU FUNCTION 324 T 324 R 325 T 325 R NC NC NC NC Door 1T Door 1R Relay 1T Relay 1R Door 2T Door 2R Relay 2T Relay 2R NC NC NC NC 310 T RJ61X 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2
DSS Console 301 SLIU
DSX Keyset 300
1
YEL BLU-WHT
BLK WHT-BLU
RED
GRN
2
625 Modular Jack
3
Station Block 2
DTH-1-1 324
Figure 14: Connecting Extensions
34
Installation
DSX-40 Hardware Manual
Connecting Extensions and Lines
Connecting Lines
A fully expanded DSX-40 can connect up to 8 analog loop-start lines with built-in Caller ID. Using Figure 10: Punch Down for Lines (page 31) as a guide, plug the installation cable plugs into the appropriate jacks on the Main Equipment Cabinet. For each line, run one pair cross-connect wire between the line block and the CPE (customer side) of the telco's RJ21X. Install bridging clips as required.
Installation
One-Pair Cross Connect
1093097 - 13
Line Block
Telco RJ21X 25-Pair Cable to Central Office
25-Pair Installation Cable (P/N 808920)
Figure 15: Installing Analog Lines
DSX-40 Hardware Manual
Installation
35
Setting Up the Telephone and DSS Console
Setting Up the Telephone and DSS Console
Installing the DSX Keyset Handset and Line Cord.
When installing the handset, plug the handset cord into the handset jack on the bottom of the telephone. The handset cord routes through the lower channel on the right side of the telephone base. The line cord does not use a channel and drapes down from the telephone line cord jack or connects to the telephone legs.
Figure 16: Installing the Handset and Line Cord
Installing the DSX Keyset Optional Headset
When installing an optional headset, plug the headset cord in the headset jack on the bottom of the telephone. The headset cord routes through the upper channel on the right side of the telephone base.
Figure 17: Installing the Optional Headset
36
Installation
DSX-40 Hardware Manual
Setting Up the Telephone and DSS Console
Installing the DSS Console Line Cord
The DSS Console connects to an available port on an 16ESIU Card, just like a keyset. [. . . ] - All keys with lamps light orange (except for MUTE which lights red). Key Names
Key Name D 0 - D 9, D * and D # 0 1 - 010 Key Name L1 - L24 S1-S4 F13 F 11 F1 F7 F8 F2
Dial pad 0-9, * and # Speed Dial bins 1-10 Super Display Soft Keys
CLEAR FLASH MUTE INTERCOM DND HOLD
1 When 1
Feature Keys 1-24 Keyset Soft Keys 1-4
CHECK TRANSFER REDIAL SPEAKER V-MAIL CONF
0 1 - 012 F 12 F4 F9 F6 F5 F3
a Super Display Soft Key is pressed, 12 # characters display adjacent to the key. Lift and replace the handset.
62
Optional Equipment
DSX-40 Hardware Manual
Connecting a PC to the System
Connecting a PC to the System
Connections for PC Programming (System Administrator) and SMDR
Use the USB or Ethernet port when connecting a PC locally for the System Administrator. Use the serial port only for SMDR.
Ethernet (auto-sensing)
CAT 5 Cable
To PC Ethernet Port USB Standard A-B USB Cable
1093097 - 26
Optional Equipment
To PC USB Port
6-Conductor Line Cord
Serial Port To PC Serial Port DSX SMDR Adaptor RJ11 Jack 6 pin, 6 conductor
123456
The DSX SMDR Adaptor is P/N 1091014.
DB9 Female Front View
5 9 4 8 3 7 2 6 1
RJ11 DTR TXD GND GND RXD DSR 1 2 3 4 5 6
DB9 4 3 5 NC 2 1 TXD DTR DSR RXD GND
Figure 41: Connecting a PC to the System
DSX-40 Hardware Manual
Optional Equipment
63
Connecting a PC to the System
64
Optional Equipment
DSX-40 Hardware Manual
Specifications and Parts
Specifications
Specifications and Parts
Specifications
DSX Telephone System Specifications
DSX-40 System Capacities (Page 1 of 2)
Cabinets: Talk Timeslots (Intercom/line): Ports Lines: Digital Telephones: Analog Telephones: DSS Consoles: DSX Analog Door Box Ports (Built-In) DSX Analog Door Boxes (With 2PGDAD Modules) Power Failure Telephones: Internal Paging Zones: External Page Audio Output:
1 Non-blocking 40 8 24 18 4 max. [. . . ]