User manual NEC DS2000 TO DSX-80

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NEC DS2000 TO DSX-80. We hope that this NEC DS2000 TO DSX-80 user guide will be useful to you.


NEC DS2000 TO DSX-80 : Download the complete user guide (701 Ko)

Manual abstract: user guide NEC DS2000 TO DSX-80

Detailed instructions for use are in the User's Guide.

[. . . ] No part of this document may be photocopied or reproduced without prior written consent of NEC Unified Solutions, Inc. Printed in U. S. A. Table of Contents Table of Contents Upgrading . 7 Site 1: Upgrade DS2000 4x8 to DSX-80 4x8 with Automated Attendant . 7 Site 2: Upgrade DS2000 8x24 with UltraMail to DSX-80 8x24 and IntraMail . [. . . ] This is required because only one DS DSTU PCB remains, supporting 16 DS telephones. Site 2 can alternately do the following: - Replace the DSX-80 4-Slot KSU with and DSX-160 8-Slot KSU. - Purchase another DSX Power Supply (due to Load Factor considerations). - Install the 16DSTU PCBs in the new DSX KSU for connecting their existing DS keysets. - Purchase a single DSX 22-Button Display Telephone for programming, and connect it to the DSX 16ESIU PCB. 8 Upgrading Upgrading DS2000 to DSX-80/160 Upgrade Examples Site 3: Upgrade DS2000 16x48 to DSX-160 16x48 with Voice Mail Site 3 is on the verge of expansion and wants to upgrade their common equipment and add voice mail. Like site 2, they do not want to invest in new station equipment. Existing DS2000 Equipment Description Part Number Description Upgrading Upgrade Requirements for DSX Part Number Comments (2) DS 8ATRU PCB 80011B Compatible - replacement not required. DSX 16COIU PCBs provide more accurate Caller ID detection. The DS CPU is not compatible with DSX. (3) DS 16DSTU PCB 80021A Compatible - replacement not required. (40) DS 34-Button Display Telephone (8) DS 34-Button Super Display Telephone (1) DS 8-Slot KSU (2) DS Power Supply (1) DS CPU 80663 80673 80001 80005C 80025B Compatible - replacement not required. (1) DSX-160 8-Slot KSU (2) DSX Power Supply 1090003 1091008 1090010 1091013 1090004 Only slots 1-4 will work with the DS 8-Slot KSU. DSX 16ESIU is required in slot 1 for DSX telephones. New DSX Equipment Required (1) DSX CPU Card (1) DSX 8x16 IntraMail (1) DSX 16ESIU Card (1) DSX 22-Button Button Display Telephone Summary: 1090020 (Black) or 1090025 (White) One DSX telephone required for telephone programming. · · To upgrade, Site 3 must invest in a new DSX-160 8-Slot KSU, two new DSX Power Supplies, DSX CPU Card, DSX 8x16 IntraMail, and a DSX 16ESIU PCB. To facilitate telephone programming, Site 3 must also add one new DSX telephone. Upgrading DS2000 to DSX-80/160 Upgrading 9 Upgrade Examples Site 4: Upgrade DS2000 16x80 (T1) to DSX-160 23x96 (PRI) Site 4 is a high-tech company that needs more telephones and wants to upgrade to PRI for cost savings. They have an existing 4 port x 8 hour IntraMail and need more capacity. Existing DS2000 Equipment Description Part Number Description Upgrade Requirements for DSX Part Number Comments (5) DS 16DSTU PCB 80021A Compatible - replacement not required. Cannot be installed in DSX KSU slot 1. The DS T1 Trunk PCB does not provide PRI when used in DSX. (40) DS 34-Button Display Telephone (40) DS 22-Button Display Telephone (1) DS 8-Slot KSU (3) DS Power Supply (1) DS CPU (1) DS 4x8 IntraMail (1) T1 Trunk PCB 80663 80573 80001 80005C 80025B 80045 80011B Compatible - replacement not required. (1) DSX-160 8-Slot KSU (3) DSX Power Supply 1090003 1091008 1090010 1091013 1091006 1090004 Only slots 1-4 will work with the DS 8-Slot KSU. DSX 16ESIU is required in slot 1 for DSX telephones. New DSX Equipment Required (1) DSX CPU Card (1) DSX 8x16 IntraMail (1) DSX T1/E1/PRI Card (1) DSX 16ESIU Card (16) DSX 22-Button Button Display Telephone Summary: 1090020 (Black) or 1090025 (White) Connect 16 DSX Telephones to the DS 16ESIU PCB in slot 1. · · · To upgrade, Site 4 must invest in a new DSX-160 8-Slot KSU, three new DSX Power Supplies, DSX CPU Card, DSX 8x16 IntraMail, a DSX T1/E1/PRI PCB, and a DSX 16ESIU PCB. In addition, Site 4 must also add 16 new DSX telephone to reach the required total of 96. For future expansion in the available slot, Site 4 can add a 16COIU Card, or another T1/E1/PRI Card. 10 Upgrading Upgrading DS2000 to DSX-80/160 DS2000 and DSX-80/160 Parts Lists Parts Lists DS2000 Parts DS2000 Parts List Station Equipment Description 34-Button Super Display Telephone 34-Button Display Telephone 22-Button Telephone 22-Button Display Telephone 24-Button DSS Console 110-Button DSS Console Wall Mount Kit Analog Telephones (customer provided) Part Number 80673 80663 80570 80573 80556 80555 80579 Peripheral Station Equipment Description 2-OPX Module (Discontinued) Part Number 92177A Upgrading DS2000 to DSX-80/160 Parts Lists 11 DS2000 Parts Common Equipment Description 4 Slot KSU 8 Slot KSU DS2000 Power Supply Part Number 80000 80001 80005B or 80005C (80005C required for UltraMail) 80892 85880 80052-V**. **. ** 80893 85980 85981 80578 PCBs Installation Cable Blank PC Card PC Card with system software preloaded (**. **. ** denotes the system software level) 8-Pin DIN to Mod-8 Cable DB9 to Mod-8 Adaptor DB25 to Mod-8 Adaptor Spare KSU Hanger Description Central Processing Unit 16DSTU Digital Station PCB 16ASTU 16 Port Analog Station PCB 8ASTU 8 Port Analog Station PCB 4ASTU 4 Port Analog Station PCB 4ATRU 4 Port Analog Trunk PCB (loop start) 8ATRU 8 Port Analog Trunk PCB (loop start) T1 Trunk PCB Part Number 80025B 80021A 80042 80041B 80040B 80010B 80011B 80061 For UltraMail part numbers, installation, and programming, refer to the Aspire Mail and UltraMail System Guide (P/N 17710SWG**). 12 Parts Lists Upgrading DS2000 to DSX-80/160 DS2000 Parts Replacement Parts Description Handset and Cord Assembly Noise Cancelling Handset 22 Button Clear Plastic Cover 34 Button Clear Plastic Cover 34 Button Super Display Clear Plastic Cover 110 Button DSS Clear Plastic Cover 24 Button DSS Clear Plastic Cover Directory Tray 9' Handset Coil Cord 13' Handset Coil Cord 25' Handset Coil Cord 7' Telephone Line Cord 14' Telephone Line Cord Wall Mount Handset Clip Holder DS2000 RFI Bead Kit Modem (CNET CN5614XR) Replacement Battery for CPU PCB Part Number 80150 80150NC 80600-22 Parts Lists 80600-34 80600-S34 80600-DSS 80600-24DSS 92602 92297-9 92297A-13 92297-25 82476-7 82476-14 80578 88901 85862D EX0254-0040 Upgrading DS2000 to DSX-80/160 Parts Lists 13 DSX-80/160 Parts DSX-80/160 Parts DSX-80/160 Parts List Station Equipment Description Part Number 22-Button Display Telephone with Speakerphone 34-Button Backlit Display Telephone with Speakerphone 34-Button Backlit Display Telephone with Full-Duplex Speakerphone 34-Button Backlit Super Display Telephone with Half-Duplex Speakerphone 60-Button DSS Console DTH-1-1 Single Line Telephone DTR-1-1 Single Line Telephone DTR-1HM-1 Single Line Telephone Analog Door Box 1090020 (Black) 1090025 (White) 1090021 (Black) 1090026 (White) 1090022 (Black) 1090027 (White) 1090030 (Black) 1090031 (White) 1090024 (Black) 1090029 (White) 780034 780020 (Black) 780021 (White) 780025 (Black) 780026 (White) 922450 DSX Cordless Lite II Telephone Description Part Number Cordless Lite II Telephone Cordless Lite II Base Unit AC Adaptor Cordless Lite II Base Unit Wall Mount Bracket Cordless Lite II Handset Charger Cordless Lite II Handset Charger AC Adaptor Cordless Lite II Wall Mount Bracket for Handset Charger Cordless Lite II Handset Battery Cordless Lite II Belt Clip Cordless Lite II M175 Headset Cordless Lite II MX150 Headset 730087 730618 730608 730632 730619 730633 730631 730634 750637 750642 14 Parts Lists Upgrading DS2000 to DSX-80/160 DSX-80/160 Parts DESI Labels Description Part Number DSX Telephone Labels DSX 22-Button Display Telephone (White) DSX 22-Button Display Telephone (Black) DSX 34-Button Display Telephone (White) DSX 34-Button Display Telephone (Black) DSX 34-Button Super Display Telephone (White) DSX 34-Button Super Display Telephone (Black) DSX 60-Button DSS (White) DSX 60-Button DSS (Black) DTR-1-1 Telephone Labels Black Metallic Green Metallic Silver Lime Green Preprint (blank) DTR-1HM-1 Telephone Labels Black Metallic Green Metallic Silver Lime Green Preprint (blank) DTH-1-1 Telephone Labels Metallic Silver 780450 780404 780405 780406 780407 780460 780400 780401 780402 780403 780459 1093086 1093085 1093084 1093083 1093082 1093081 1093080 1093079 Parts Lists Upgrading DS2000 to DSX-80/160 Parts Lists 15 DSX-80/160 Parts Common Equipment Description Part Number DSX-80 4-Slot KSU DSX-160 8-Slot KSU DSX Power Supply Installation Cable DSX Serial Adaptor (requires customer-provided 6-conductor line cord) Cards Description 1090002 1090003 1091008 80892 1091014 Part Number CPU Card 16 Port Digital Station Card (16ESIU) 16 Port Analog Station Card with HV Message Waiting (16SLIU) 8 Port Analog Station Card with HV Message Waiting (8SLIU) T1/E1/PRI Line Card 16 Port CO Line Card (16COIU) 8 Port CO Line Card (8COIU) IntraMail Description 1090010 1091004 1091007 1091010 1091006 1091005 1091009 Part Number IntraMail 8 Port x 16 Hour IntraMail 4 Port x 8 Hour 1091013 1091011 16 Parts Lists Upgrading DS2000 to DSX-80/160 DSX-80/160 Parts Replacement Parts Description Part Number Handset and Cord Assembly 22 Button Clear Plastic Cover 34 Button Clear Plastic Cover 34 Button Super Display Clear Plastic Cover 60 Button DSS Clear Plastic Cover RFI Bead Kit Replacement Battery for CPU Card 1091016 1091018 1091019 1091020 1091021 88901 EX0254-0040 Parts Lists Upgrading DS2000 to DSX-80/160 Parts Lists 17 DSX-80/160 Parts 18 Parts Lists Upgrading DS2000 to DSX-80/160 DS-Series to DSX Program Cross Reference Cross Reference From DS-Series to DSX Cross Reference Cross Reference From DS-Series to DSX DS-Series to DSX Cross Reference Chart DS to DSX Programming Cross Reference DS Program DS Program Description DSX Program 0101 Class of Service Option Off Premise Call Forward . . 1406-01 1402-02 1402-03 1406-02 1401-01 1401-02 1401-03 1411-02 1402-01 1411-01 1407-01 1407-02 1407-03 1407-04 1407-05 1407-06 1407-07 1407-08 1402-04 1403-01 1401-04 1403-02 DS-Series to DSX Program Cross Reference 19 Cross Reference From DS-Series to DSX DS to DSX Programming Cross Reference DS Program DS Program Description DSX Program View System Alarms Automatic Hold . . 0201 Tenant Option Programming 1411-03 1402-05 1402-06 1401-05 1401-06 1404-01 1404-02 1404-03 1404-04 1412-04 1412-05 1412-06 1405-01 1405-02 1405-03 1403-03 1403-04 1403-05 1403-06 1411-04 1412-01 1412-02 1412-03 1401-07 1411-05 1401-08 1401-09 1404-05 1404-06 1401-10 1401-11 1401-12 1512-02 1513-02 1513-01 1512-01 1521-01 1521-02 1521-03 1541-02 1541-01 1541-04 1541-03 1511-01 2101-06 2101-06 Call Waiting (Camp-On) Tone. Door2 Relay Page Zone Assignment 20 DS-Series to DSX Program Cross Reference Cross Reference From DS-Series to DSX DS to DSX Programming Cross Reference DS Program DS Program Description DSX Program 0202 Ring Over External Page Options Background Music Over External Page . . 0203 UNA Ringing Over External Page 1521-04 1531-04 1531-03 1531-01 1531-02 Trunk Port . 1532-01 UNA Ringing Option 0301 System Options (Part 1) Number of Operators. . 0302 System Identification 1501-01 1502-01 1502-02 1502-03 1502-04 1701-01 1111-01 Cross Reference 1541-01 1541-02 1541-03 1011-01 1011-02 1001-01 1001-02 1021-01 1021-02 1022-01 1511-02 1603-04 1603-01 1602-01 1605-02 1602-04 1605-01 1605-03 1601-02 1601-01 1604-01 1601-04 N/A 1605-04 1602-06 1602-07 Company Name. [. . . ] . 8008 IntraMail Dial Action Tables 4212-XX-XX 4212-XX-XX 4212-XX-XX 4212-XX-XX 4231-XX-01 4231-XX-02 4231-XX-03 4231-XX-04 4231-XX-05 4231-XX-06 4231-XX-07 4231-XX-08 4231-XX-09 4231-XX-10 4231-XX-11 4231-XX-12 4231-XX-13 Digit "1" . . 9804 9901 9902 9902 9114-01 2103-0X 2103-0X 2103-0X 2103-0X Initialize Caller ID Log Utility. Install Swap Remove Ports 9903 9903 9904 Set Up Trunks (DS1000) Set Up Trunks (DS2000) T1/E1 Configuration Clock Control . . 1213-02 1213-03 1213-04 1213-05 1213-01 1213-06 DS-Series to DSX Program Cross Reference 31 Cross Reference From DS-Series to DSX DS to DSX Programming Cross Reference DS Program DS Program Description DSX Program 9905 9906 9907 9908 9988 9998 9999 Password . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NEC DS2000 TO DSX-80




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NEC DS2000 TO DSX-80 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.