User manual NAD C 275BEE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NAD C 275BEE. We hope that this NAD C 275BEE user guide will be useful to you.


NAD C 275BEE : Download the complete user guide (364 Ko)

You may also download the following manuals related to this product:

   NAD C 275BEE (373 ko)
   NAD C 275BEE (378 ko)
   NAD C 275BEE (368 ko)
   NAD C 275BEE (369 ko)
   NAD C 275BEE (403 ko)
   NAD C 275BEE (369 ko)
   NAD C 275BEE (365 ko)
   NAD C 275BEE (365 ko)

Manual abstract: user guide NAD C 275BEE

Detailed instructions for use are in the User's Guide.

[. . . ] ® Owner’s Manual Stereo Power Amplifier C 275BEE РУССКИЙ SVENSKA NEDERLANDS DEUTSCH ITALIANO ESPAÑOL FRANÇAIS ENGLISH IMPORTANT SAFETY INSTRUCTIONS ENGLISH FRANÇAIS ESPAÑOL ITALIANO DEUTSCH NEDERLANDS SVENSKA РУССКИЙ Save these instructions for later use. 1 Read instructions - All the safety and operating instructions should be read before the product is operated. 2 Retain instructions - The safety and operating instructions should be retained for future reference. 3 Heed Warnings - All warnings on the product and in the operating instructions should be adhered to. [. . . ] When the C 275BEE is at ON state, this indicator will illuminate blue. 3 BRIDGE MODE INDICATOR: This BRIDGE MODE indicator lights up blue when the C 275BEE is switched to Bridge Mode. Refer also to the item below about BRIDGE MODE at the IDENTIFICATION OF CONTROLS – REAR PANEL. 4 SOFT CLIPPING INDICATOR: The blue SOFT CLIPPING LED shows that the SOFT CLIPPING mode is engaged. Refer also to the item below about SOFT CLIPPING at the IDENTIFICATION OF CONTROLS – REAR PANEL. 1 2 3 4 ITALIANO DEUTSCH NEDERLANDS SVENSKA РУССКИЙ In cases of serious abuse of the C 275BEE, such as excessively low loudspeaker impedance and short circuit, the C 275BEE will engage its Protection circuitry, indicated by the Standby LED turning from blue to red and the sound being muted. In such a case, turn the C 275BEE OFF by the rear panel POWER switch, wait for it to cool down and/or check the speaker connections, making sure the overall loudspeaker impedance doesn’t go below 4 ohms or 8 ohms in Bridge mode. Once the cause for the protection circuitry to engage has been removed, switch ON the rear POWER button and the Standby Button to resume normal operation.  IDENTIFICATION OF CONTROLS REAR PANEL 9 10 11 1 2 3 4 5 6 7 8 ATTENTION! Please make sure that the C 275BEE is powered OFF or unplugged before making any connections. It is also advisable to power-down or unplug all associated components while making or breaking any signal or AC power connections. 1 INPUT SELECT: Slide this switch to either “FIX” or “VAR”. When it is set to FIX, the input signal is taken straight to the power amplifier’s circuitry. This setting is normally used in a system with only one power amplifier or multiple but identical power amplifiers. When the INPUT SELECT switch is set to “VAR” (Variable), it is possible to adjust the volume level for both channels simultaneously, using the INPUT LEVEL CONTROL. This can be useful for: Level Matching In a surround sound or system with more than one set of speakers, differences in levels can occur due to variance inefficiencies between these speakers. In case your preamplifier or processor also has individual trims for each channel, set these to neutral or mid position (usually marked as 0dB). Adjust the INPUT LEVEL CONTROL so that the speakers driven by the C 275BEE have the correct volume level compared to the other speakers, judging from your listening position. Extended Volume Control Range Many systems have so much voltage gain that the speakers (or your ears) are overdriven at any volume control setting higher than 11 or 12 o’clock. As a result you are confined to using only the lower half of the volume control’s range, where adjustments are imprecise and where channel balance errors tend to be greater. If the input level is reduced, you can turn up the volume control of your processor or preamplifier, making more effective use of its range. (Suggestion: adjust the input level controls so that your preferred maximum sound levels usually occur at about 2 or 3 o’clock on the volume control. ) As an added benefit, this procedure suppresses any noise produced by the preamplifier’s high level circuitry (e. g. any residual hum or hiss that does not go away when the Volume is turned down). Bi-Amping Some loudspeakers have separate connection terminals for their LF (Low Frequency) and HF (High Frequency) sections. [. . . ] Before connecting the cable to a live wall socket ensure that it is firmly connected to the C 275BEE’s AC Mains input socket first. Connect only to the prescribed AC Outlet, i. e. , 120V 60 Hz or 230V 50 Hz. Always disconnect the AC Mains cable plug from the live wall socket first, before disconnecting the cable from the C 275BEE’s Mains input socket. 11 POWER SWITCH: The POWER switch supplies the master AC mains power for the C 275BEE. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAD C 275BEE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NAD C 275BEE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.