User manual MULTICOAT MULASTICOAT

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MULTICOAT MULASTICOAT. We hope that this MULTICOAT MULASTICOAT user guide will be useful to you.


MULTICOAT MULASTICOAT : Download the complete user guide (1164 Ko)

Manual abstract: user guide MULTICOAT MULASTICOAT

Detailed instructions for use are in the User's Guide.

[. . . ] 1/8" GAP BETWEEN PANELS) Replaces Shear Panel Flexible G High Impact and Abrasion Resistance G Resists Moisture Penetration and Formation of Fungus and Mildew G Resistant to Salt Spray, Freeze/Thaw, and Most Chemicals G UV Resistant G Easy to Install G Multiple Finishes - Smooth - Medium - Coarse G Multiple Color Choice G Waterbase Stucco Emulsion Environmentally Safe SEE TEST DATA CAULK ALL JOINTS WITH POLYURETHANE CAULK (ALLOW TO CURE) SURFACE PREPARATION Smooth primed fibercement siding must be structurally sound, and surface must be free from grease, oil, paint, dirt, dust, sealers, laitence, and other foreign materials that may PREVENT PROPER BONDING. Proper expansion joints should be installed according to applicable local building codes or structural engineer. [. . . ] Proper expansion joints should be installed according to applicable local building codes or structural engineer. (Recommended: Approximately every 16 feet when wall has no openings. ) NOTE: A mositure barrier or house wrap may be necessary in some applications. Check local building codes or structural engineer. APPLY MULTICOAT ELASTOMERIC JOINT TAPE TO CORNERS AND JOINTS APPLICATION STEP 1: Install smooth primed fibercement siding on existing structure using galvanized nails (wood) or self-tapping ceramic coated screws (steel), 6" centers. All panel edges shall be supported by framing, per manufacturer's instructions. Allow caulk to thoroughly cure. Clean wall board with water dampened sponge. STEP 2: Tape all caulked joints with Multicoat elastomeric 3" joint tape. Seller's sole obligation shall be to replace material if found to be defective. Seller shall not be liable for any loss, direct or consequential, resulting from use of its products. Outside Corner (Optional) Primed Fibercement Panel PACKAGING AND STORAGE SMOOTH PRIMED FIBERCEMENT SIDING - 4' wide x 8, 9, 10 or 12 ft. Lengths STANDARD THICKNESS - 5/16" ­ Special Order 7/16" MULTICOAT STUCCO MIX - 5-Gal. Pails STUD 2' X 4' BOTTOM PLATE 2' X 4' FLOORING PRIMED FIBERCEMENT PANEL ADHESIVE FOAM OR MIX PANEL ATTACHED OR GLUED TO TOP SHEET ONLY 1/8" GAP 3/8" CLEAR HORIZONTAL EXPANSION JOINT REVEAL Straight Joint Primed Fibercement Panel Tape and joining system by coating applicator Multicoat Stucco Mix over Primed Fibercement Panel 1/8" gap Straight Joint Detail External Corner Bead Primed Fibercement Panel FLOOR JOIST 2' X 6' TOP PLATE 2' X 4' PRIMED FIBERCEMENT PANEL NAILED TO TOP PLATE, FLOATING ON JOIST AND FLOOR Reinforcing tape Primed Fibercement Panel edges Multicoat Stucco Mix STUD 2' X 4' External Corner STUD 2' X 4' BOTTOM PLATE 2' X 4' FLOORING 1. 8" GAP 3/8" CLEAR HORIZONTAL EXPANSION JOINT REVEAL Sealant External Corner Detail PRIMED FIBERCEMENT PANEL SMOOTH Primed Fibercement Panel External Bullnose Corner Bead Outside Corner (Optional) FLOOR JOIST 2' X 6' TOP PLATE 2' X 4' PRIMED FIBERCEMENT PANEL NAILED TO TOP PLATE, FLOATING ON JOIST AND FLOOR Tape and joining system by coating applicator Multicoat Stucco Mix Primed Fibercement Panel Primed Fibercement Panel Finish 3/16" gap 2' Internal Corner Primed Fibercement Panel Internal Corner Detail Weep Screed 3/8" Foundation TEST DATA ­CEMENTITIOUS WALL BOARD ICC/ES Report #5139 Thicknesses: Installed Weight: 1/4" thick 5/16" thick 7/16" thick Density: Bending Strength: Transversal: Longitudinal: 1/4", 5/16" & 7/16" 1. 9 lbs/sq. ft. 2, 000 psi 2, 500 psi SBCCI Report #9556 Thermal Resistance: Shrinking: Ambient to oven-dry: Swelling of Thickness (after 7 days of full saturation): Flame Spread: Smoke Density: Wind Pressures: Shear Values: R=0. 17 0. 06% 0. 2% 0 0 TEST DATA ­STUCCO MIX TEST TYPE TEST METHOD RESULTS No marked evidence of surface cracking, blistering, flaking, chalking, crazing or any other deleterious effects observed No blistering or cracking of surface No change in color, no cracks, no crazing, no delamination Initial wear started at 3200 liters Passed 4. 56 Perms, the coating is not a vapor barrier 2000 Hour Weatherometer . . Section VI D of acceptance criteria for EIFS Abrasion Test (Falling Sand) . [. . . ] Pails STUD 2' X 4' BOTTOM PLATE 2' X 4' FLOORING PRIMED FIBERCEMENT PANEL ADHESIVE FOAM OR MIX PANEL ATTACHED OR GLUED TO TOP SHEET ONLY 1/8" GAP 3/8" CLEAR HORIZONTAL EXPANSION JOINT REVEAL Straight Joint Primed Fibercement Panel Tape and joining system by coating applicator Multicoat Stucco Mix over Primed Fibercement Panel 1/8" gap Straight Joint Detail External Corner Bead Primed Fibercement Panel FLOOR JOIST 2' X 6' TOP PLATE 2' X 4' PRIMED FIBERCEMENT PANEL NAILED TO TOP PLATE, FLOATING ON JOIST AND FLOOR Reinforcing tape Primed Fibercement Panel edges Multicoat Stucco Mix STUD 2' X 4' External Corner STUD 2' X 4' BOTTOM PLATE 2' X 4' FLOORING 1. 8" GAP 3/8" CLEAR HORIZONTAL EXPANSION JOINT REVEAL Sealant External Corner Detail PRIMED FIBERCEMENT PANEL SMOOTH Primed Fibercement Panel External Bullnose Corner Bead Outside Corner (Optional) FLOOR JOIST 2' X 6' TOP PLATE 2' X 4' PRIMED FIBERCEMENT PANEL NAILED TO TOP PLATE, FLOATING ON JOIST AND FLOOR Tape and joining system by coating applicator Multicoat Stucco Mix Primed Fibercement Panel Primed Fibercement Panel Finish 3/16" gap 2' Internal Corner Primed Fibercement Panel Internal Corner Detail Weep Screed 3/8" Foundation TEST DATA ­CEMENTITIOUS WALL BOARD ICC/ES Report #5139 Thicknesses: Installed Weight: 1/4" thick 5/16" thick 7/16" thick Density: Bending Strength: Transversal: Longitudinal: 1/4", 5/16" & 7/16" 1. 9 lbs/sq. ft. 2, 000 psi 2, 500 psi SBCCI Report #9556 Thermal Resistance: Shrinking: Ambient to oven-dry: Swelling of Thickness (after 7 days of full saturation): Flame Spread: Smoke Density: Wind Pressures: Shear Values: R=0. 17 0. 06% 0. 2% 0 0 TEST DATA ­STUCCO MIX TEST TYPE TEST METHOD RESULTS No marked evidence of surface cracking, blistering, flaking, chalking, crazing or any other deleterious effects observed No blistering or cracking of surface No change in color, no cracks, no crazing, no delamination Initial wear started at 3200 liters Passed 4. 56 Perms, the coating is not a vapor barrier 2000 Hour Weatherometer . [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MULTICOAT MULASTICOAT




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MULTICOAT MULASTICOAT will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.