User manual MORPHY RICHARDS ESSENTIALS CYCLONIC BAGLESS UPRIGHT VACUUM CLEANER REV 1

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MORPHY RICHARDS ESSENTIALS CYCLONIC BAGLESS UPRIGHT VACUUM CLEANER. We hope that this MORPHY RICHARDS ESSENTIALS CYCLONIC BAGLESS UPRIGHT VACUUM CLEANER user guide will be useful to you.


MORPHY RICHARDS ESSENTIALS CYCLONIC BAGLESS UPRIGHT VACUUM CLEANER REV 1: Download the complete user guide (827 Ko)

Manual abstract: user guide MORPHY RICHARDS ESSENTIALS CYCLONIC BAGLESS UPRIGHT VACUUM CLEANERREV 1

Detailed instructions for use are in the User's Guide.

[. . . ] This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. To protect against fire, electric shock and personal injury, do not immerse cord, plug or cleaner in water or other liquid. Product safety · Never use the appliance without the filters being installed. Never use the appliance to vacuum hot ashes, broken glass, sharp objects or liquids. If the cleaner is knocked over, switch off before attempting to upright. [. . . ] Note: The height adjustment only comes into effect when the handle is released by the handle release pedal È. 4 For Advice, Spares or Accessories, tel: 0845 077 7700 (UK) or 1800 409 119 (Ireland) 73332 rev1 17/10/07 10:40 Page 5 Using the attachments Follow steps 1-4 but set the carpet height adjustment knob to the TOOLS setting. IMPORTANT: Always fix the hose clip ~ to the main body slot Ë when using the hose and tools. IMPORTANT: Turning the cleaner sideways helps prevent the cleaner being pulled along by the stretch hose. 1 2 Using the Hair and stair tool (Certain models only) Attach the stair tool to the hose connector Í for effective stair cleaning. Attach the hair tool to the stair tool for fantastic pet hair pick-up D. E · · EMPTYING Empty the dust canister regularly even if it does not look full, this will maintain the performance. Lift-up the dust canister release Î and pull the canister away from the main body. Turn the lid quarter-of-a-turn anti-clockwise to unlock, lift off the lid with pleated filter Ì, put to one side F. Lift out the central mesh filter Ô from the dust canister Ó G. Re-fit pleated filter with lid into the dust canister by lining up the two arrows and turning the lid quarter-of-a-turn clockwise to lock. 6 · · 3 4 5 Using & cleaning the turbo nozzle (Certain models only) Attach the turbo nozzle to the hose end connector Í. If they are tightly wound around the brush, carefully snip the fibres with scissors, being careful not to damage the brush bar, pull away from the brush bar and dispose. 6 7 8 9 F 10 Re-fit dust canister into cleaner and push to lock into position. 11 Re-fit the front cover. G D www. morphyrichards. com 5 73332 rev1 17/10/07 10:40 Page 6 H SAFETY CUT-OUT If the cleaner overheats, a motor protection thermostat will automatically switch the motor off. If this happens, switch the cleaner off, unplug from the power supply and leave the cleaner to cool for at least 60 minutes. Check the airways for blockages, empty the dust canister and clean the filters before restarting. Exhaust filter J The exhaust filter is located below the dust canister compartment. Remove the exhaust filter Ú by pulling forward at the top and lifting it away. Replace the filter and the front cover. 3 CLEANING THE FILTERS I Ò To maintain suction, the pleated filter must be shaken clean each time the dust canister is emptied. Failure to clean the filter will reduce suction and could damage the motor if used for a prolonged period. 4 Changing the belt If the brush bar stops rotating, it is likely that the drive belt has snapped (usually because the brush has been stalled). Replacement belts can also be obtained from Morphy Richards by calling the helpline number at the base of the page. Pleated filter J This must be shaken clean at every emptying to maintain suction. To remove it from the dust canister lid, turn the filter quarter-of-a-turn anti-clockwise H. Wash in warm water (no detergent) and allow to air dry before refitting. Accessing the floor nozzle K 1 2 3 4 Disconnect the cleaner from the mains supply. Press the handle release pedal and place the cleaner face down, in a flat position on a soft surface (eg. Using a flat bladed screwdriver or a coin, rotate the three cover fixings, a quarter-of-a-turn, from lock to unlock K. [. . . ] This guarantee does not confer any rights other than those expressly set out above and does not cover any claims for consequential loss or damage. This guarantee is offered as an additional benefit and does not affect your statutory rights as a consumer. This guarantee is valid in the UK and Ireland only. 5 6 · · EXCLUSIONS The fault has been caused or is attributable to accidental use, mis-use, negligent use or used contrary to the manufacturer's recommendations or where the fault has been caused by power surges or damage caused in transit. The appliance has been used on a voltage supply other than that stamped on the products. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MORPHY RICHARDS ESSENTIALS CYCLONIC BAGLESS UPRIGHT VACUUM CLEANER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MORPHY RICHARDS ESSENTIALS CYCLONIC BAGLESS UPRIGHT VACUUM CLEANER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.