User manual MONITOR AUDIO VECTOR V1 2008

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MONITOR AUDIO VECTOR. We hope that this MONITOR AUDIO VECTOR user guide will be useful to you.


MONITOR AUDIO VECTOR V1 2008: Download the complete user guide (1338 Ko)

Manual abstract: user guide MONITOR AUDIO VECTORV1 2008

Detailed instructions for use are in the User's Guide.

[. . . ] This exclamation point within an equilateral triangle is intended to alert the user to presence of important maintenance (servicing) instructions in the literature accompanying the appliance. Unplug this apparatus during lightening storms, or when unused for long periods of time. Servicing is required when the apparatus has been damaged in any way, such as power supply cord or plug is damaged, liquid has been spilled or objects have fallen onto the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped. This apparatus shall not be exposed to dripping or splashing water and that no object filled with liquids such as vases shall be placed on the apparatus. [. . . ] The feet are factory fitted to your product to allow for swift installation and enjoyment of you new purchase. When set to the `Off' position the crossover frequency control (section 4) is activated and can be adjusted from 45Hz to 150Hz using the crossover frequency control. When set to the `Off' position it can be used with an amplifier that does not have a dedicated subwoofer or LFE output, such as a stereo 2-channel amplifier. if the amplifier or AV processor has a dedicated LFE or subwoofer output , the By Pass Filter Switch should be set to the `On' position. The low pass filter will then be set by the AV amplifier's internal filter. This is set in accordance with the amplifier or AV processor user guide. The table below will help you to select the correct frequency at which to crossover depending on your main speakers. The LED indicates whether the unit is in stand-by mode or operational. It will be illuminated red when in stand-by, and green when operational. The logo badge on the front of the cabinet will also illuminate red and green depending on operational state. This control allows the subwoofer level or loudness to be adjusted in order that you can achieve a totally controlled, balanced sound. Power Mode Switch in the `Auto' position, the unit should remain in standby with the power LED around the Logo Badge on the front and on the amp panel should be red, until the AV amp is turned on or a signal is received. To manually set up you sub, play a variety of music/ film excerpts that you are familiar with starting at a very low volume level, increasing to an average listening level once you are sure everything is working correctly. please now follow the instructions below: · For use with an AV amp/receiver (product with Subwoofer output) please select the by pass filter switch to the `On' position. If using the crossover frequency control please adjust in accordance with the table on page 5. ⷠThe Phase Control can now be set, please refer to pages 4 for further information. It is important to try a variety of music and film excerpts with which you are familiar in order to obtain the optimum overall settings. If you use this to set up your sub, please remember to go back into the settings of your AV amp and check them. You may need to go back and manually fine tune, both on the sub and on the AV amp to achieve optimum performance. Should you experience any technical, or set-up problems with your subwoofer please check the Trouble Shooting Guide below: My subwoofer will not turn on/no power. If not, then check your mains lead is properly connected both at the subwoofer and at the mains outlet. also check the fuse of the mains plug (where fitted) and also the fuse in the subwoofer. [. . . ] The liability of Monitor Audio is limited to the cost of repair or replacement of the defective parts (at the discretion of Monitor Audio) and under no circumstances extends to consequential losses or damage. Declare in own responsibility, that the Vector VW-8 product described in this manual is in compliance with Technical Standards/Council Directives: (LVD) 73/23/EEC Low Voltage Directive EN60065: 09. Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current up and including 16 Ampere per phase and not subject to conditional connection. The equipment should be returned in its original packaging to the original supplier where possible, or to any other authorised Monitor Audio dealer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MONITOR AUDIO VECTOR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MONITOR AUDIO VECTOR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.