User manual MK ELECTRIC MASTERSEAL SENTRY TECHNICAL DATA SHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MK ELECTRIC MASTERSEAL SENTRY. We hope that this MK ELECTRIC MASTERSEAL SENTRY user guide will be useful to you.


MK ELECTRIC MASTERSEAL SENTRY TECHNICAL DATA SHEET: Download the complete user guide (233 Ko)

Manual abstract: user guide MK ELECTRIC MASTERSEAL SENTRYTECHNICAL DATA SHEET

Detailed instructions for use are in the User's Guide.

[. . . ] TECHNICAL DATA SHEET Masterseal Sentrysocket 1:2 MastersealTM Sentrysocket® PRODUCT RANGE RCD protected switchsocket outlets 30mA Active Control Single socket Single socket Double socket 30mA Passive Control Double socket 56233 GRY 56301 GRY 56301 WHI 56231 GRY Description Sentrysocket provides a high level of protection against electrocution and gives further protection when used with appliances vulnerable to insulation damage, particularly when they are in damp environments or outdoors. [. . . ] This makes them ideal for use where it would be hazardous for equipment to suddenly energise after return of mains power, such as use with rotating machinery and heat developing apparatus. Passive control circuit Incorporates a `Stay-set' mechanism and is mains failure proof, ie it will function under all the normal conditions expected of an RCD and will not trip in the event of a power cut. This makes it suitable for use with freezers or in inaccessible or unmanned locations. Compliance with EC Directives, Standards and approvals All Sentrysockets comply with the following EC Directives and are CE marked: Low Voltage Directive (73/23/EEC) Electromagnetic Compatibility Directive (89/336/EEC) Sentrysocket RCD Single Sockets also comply with the requirements of the following standards: BS 7288: 1990 (1993) BS 2011 Part 2. 1 Db (Damp Heat - cyclic) BS 2011 Part 2. 1 Ka (Salt mist) BS EN 50082-1 Sentrysocket RCD Double Sockets comply with BS 7288: 1990 (1993) and BS EN 61543: 1996 for EMC Features I Suitable for most residential, commercial and light industrial applications. Active and passive control circuit applications Comply fully with current Wiring Regulations Double pole switching I I I I I Flexible and versatile in use Ideal for use with equipment subject to wet weather or high humidity Part of a complete range of MK circuit protection devices They are a. c. sensitive for residual current Enclosure IP56 I I I ©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric. co. uk www. mkelectric. co. uk Edition 06-02 TECHNICAL DATA SHEET Masterseal Sentrysocket 2:2 Dimensions (mm) Single and double sockets are identical in size and shape. The following dimensions apply 175 80 115 Fixing Dimensions 67 TECHNICAL SPECIFICATION Electrical Rated Voltage: 240V a. c. [. . . ] installation altitude: 2000 metres 72. 5 Conduit Entry Centre Lines 36. 25 157. 5 Masterseal products are suitable for surface mounting only. ©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric. co. uk www. mkelectric. co. uk Edition 06-02 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MK ELECTRIC MASTERSEAL SENTRY




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MK ELECTRIC MASTERSEAL SENTRY will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.