User manual MK ELECTRIC LOGIC PLUS TECHNICAL SWITCHSOCKET OUTLETS DATA SHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MK ELECTRIC LOGIC PLUS TECHNICAL SWITCHSOCKET OUTLETS. We hope that this MK ELECTRIC LOGIC PLUS TECHNICAL SWITCHSOCKET OUTLETS user guide will be useful to you.


MK ELECTRIC LOGIC PLUS TECHNICAL SWITCHSOCKET OUTLETS DATA SHEET: Download the complete user guide (603 Ko)

Manual abstract: user guide MK ELECTRIC LOGIC PLUS TECHNICAL SWITCHSOCKET OUTLETSDATA SHEET

Detailed instructions for use are in the User's Guide.

[. . . ] TD1 Logic Plus Technical WHITE www. mkelectric. co. uk Switchsocket Outlets Standards and approvals All Logic Plus 13A socket outlets comply with BS 1363: Part 2: 1995. Replacement fuses to the 3 gang socket outlets comply with BS 1362: 1973. Technical specification Electrical Voltage rating: 250V a. c. Current rating: 13A per socket outlet (except 3 gang which is 13 amp in total) Terminal capacity: Live, neutral & earth 3 x 2. 5mm2 3 x 4mm2 2 x 6mm2 (standard) (Dual earth terminals on list Nos. K781 WHI, K2657 WHI, K2737 WHI, K2746 WHI, K2757 WHI) Physical Ambient operating temperature: ­5°C to +40°C (not to exceed an average of more than 25°C in any 24 hour period) IP rating: IP2XD Max. [. . . ] They are only suitable for use with normal tungsten filament lamps with internal fuses, conforming to BS EN 60064: 1996 and BS EN 60432-1 Standards and do not have any added features, e. g. soft start, ability to control dimmable transformers for low voltage, etc. Standard Dimmer Switches are not suitable for use with transformers for Low Voltage Lighting or Fluorescent Loads, including Energy Saving Lamps. Intelligent Dimmer Switches Dimmer Switches belonging to this category, employ the latest, state of the art, micro-controller based electronic circuitry and use current sensing to compute the load conditions. These products show progressive reaction to overload conditions, depending on the extent of overload as shown in the table below. List numbers belonging to this category are identified by the suffix letters LV, e. g. All MK Intelligent Dimmer Switches employ one pole change over switches to facilitate two way switching. MK Intelligent Dimmer Switches are not suitable for use with Fluorescent Loads, including Energy Saving Lamps. Only one Dimmer Switch can be used in a two-way switching circuit. OVERLOAD REACTION Case Approximate load on the dimmer as a percentage of its maximum load Up to 125% >125% to 150% >150% to 200% Power output to load when dimmer control is set to maximum 1 2 3 Load will receive maximum power continuously. Output to load will be reduced to 50% of the maximum after a delay of approximately 20 seconds after switch on. Output to load will be reduced to the minimum setting of the dimmer after a delay of approximately 20 seconds after switch on. Output will be disabled (load will be switched off) almost instantaneously after switch on. 4 >200% Non-UK Dimmer Switches Dimmer switches belonging to this category only conform to the relevant parts of BS 5518, without conforming to BS 800. Loads suitable for use with standard dimmer switches above are also suitable for use with this category of dimmer switch. For a full range of corresponding products, see pages 28­29 in the product selector. Logic Plus Technical TECHNICAL HOTLINE +44 (0)1268 563720 WHITE TD18 Dimmer Switches Features Intelligent Dimmer Switches incorporate the following advanced features Dimensions (mm) 86 28 Suitable for dimming Low Voltage Halogen lamps via good quality, fully dimmable electronic or wire-wound transformers Can be used with good quality mains voltage halogen lamps incorporating GU10 bases. Please check with lamp manufacturer to determine suitability Unidirectional current sensing. While being used with wire-wound transformers for low voltage lighting, these dimmer switches continuously monitor the drive conditions to the transformers, which require essentially, bidirectional a. c. If, due to some fault condition, the supply to the wire-wound transformer is detected to be unidirectional, which could result in over-heating and/or damaging the transformer, the dimmer switches' circuitry automatically stops supplying the transformer after a few cycles of detected unidirectional supply Soft Start, which gradually increases the light output from the load over 1 to 3 seconds after switch on. The Soft Start feature is also particularly beneficial when used to dim Mains Voltage Tungsten Halogen lamps which have inherent very high inrush current at switch on 1 gang single dimmer 86 19 16 60. 3 18 INTELLIGENT DIMMER SWITCHES Rating Max No. of Transformers (total rating of all transformers must not exceed maximum VA rating of dimmer) 4 4 per dimmer 5 Standard Dimmer Switches Suitable only for use with fused GLS Tungsten Filament lamps to BS EN 60064 and BS EN 60432-1 One way dimmer switches incorporate manual soft start Incorporate thermal switches for protection against overload 40-300W (LV and mains voltage halogen rating 40-240W/VA) 1 gang double 2 x 40-300W (LV and mains voltage dimmer halogen rating 2 x 40-240W/VA) 1 gang single dimmer 60-500W (LV and mains voltage halogen 60-400W/VA) One-way switching L Supply 230V a. c. - 50Hz L1 L2 Load C DIMMER N Two-way switching (only one dimmer can be used) 2 way switch L1 C L2 L1 L2 C N Supply 230V a. c. - 50Hz Load DIMMER L Wires must be connected to the correct dimmer terminals. DO NOT connect earth to dimmer. Please note the dimmer may be substituted for any of the Two-Way switches shown on pages 27-28 TD19 Logic Plus Technical WHITE www. mkelectric. co. uk Euro and LJU6C Data Frontplates Standards and approvals BS 5733 Technical specification Dimensions Height: Width: 85. 75mm 85. 75mm (1G) 147mm (2G) Depth: 9mm Description Frontplates used for mounting snapfit data modules. Euro modules are available separate or already mounted to save on installation time. Aperture Dimensions Euro Frontplates Height: Width: 50mm 50mm (1G) 100mm (2G) LJU6C Frontplates Height: Width: Weight 1G 1 module: 1G 2 module: 2G 4 module: Colour MK White 32g (including fixing screws) 28g (including fixing screws) 39g (including fixing screws) 37mm 22mm Dimensions (mm) Euro Frontplates 86 9 LJU6C Frontplates 86 9 1 Gang 2 module 86 86 60. 3 60. 3 K182 WHI 2 Gang 4 module 147 9 K172 WHI Features 1G and 2G frontplates Logic Plus style Colour matched to MK Logic Plus range Accept industry standard (Euro) and LJU6C snapfit modules 1G Euro frontplate accepts 2 Euro modules, (50 x 50mm aperture) 2G Euro frontplate accepts 4 Euro modules, (100 x 50mm aperture) 2G LJU6C frontplate accepts two LJU6C modules (27 x 37mm aperture) 1/2 module (12. 5 x 50mm) blank available for Euro frontplates 86 120. 6 K184 WHI For a full range of corresponding products, see pages 30­31 in the product selector. Logic Plus Technical TECHNICAL HOTLINE +44 (0)1268 563720 WHITE TD20 Power Modules Standards and approvals K5830: BS 1363: Part 2: 1995 K5831: IEC 60884-1: 2002 K5832: SSA. 444: 1985 Description A range of euro modules designed to provide a variety of power options. Technical specification 13A UK Electrical Voltage rating: 250V a. c. [. . . ] 400) carefully push each lead into the appropriate IDC terminals according to the wiring colour code stated in the BT Wiring Scheme diagram. Pins 1 and 6 are frequently unused, 4 wire cable may be used in these installations. If an existing installation uses a different wiring colour code system, this should be retained on any new or extended installation. Additional secondary extension outlets should be wired in parallel with the existing installation via the IDC terminals, (i. e. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MK ELECTRIC LOGIC PLUS TECHNICAL SWITCHSOCKET OUTLETS




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MK ELECTRIC LOGIC PLUS TECHNICAL SWITCHSOCKET OUTLETS will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.