User manual MK ELECTRIC LOGIC PLUS SHAVER SOCKET OUTLET DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MK ELECTRIC LOGIC PLUS SHAVER SOCKET OUTLET. We hope that this MK ELECTRIC LOGIC PLUS SHAVER SOCKET OUTLET user guide will be useful to you.


MK ELECTRIC LOGIC PLUS SHAVER SOCKET OUTLET DATASHEET: Download the complete user guide (149 Ko)

Manual abstract: user guide MK ELECTRIC LOGIC PLUS SHAVER SOCKET OUTLETDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] TECHNICAL DATA SHEET Logic Plus Shaver Socket Outlet 1:1 Logic PlusTM Shaver Socket Outlet PRODUCT RANGE Shaver socket outlet 200-250 volt input Description Designed for ease of installation and having many of the advantageous features of the Logic Plus range. [. . . ] Plug pin apertures, and engagement face dimensions comply with BS 4573: 1970. British 5mm dia pins on 16. 6mm pitch (230V socket) to BS 4573: 1970. European 4mm dia pins on 17 to 19mm pitch (230V socket) to IEC 83: 1975 Standard C5. Features I I TECHNICAL SPECIFICATION Electrical Voltage rating: 200-250V a. c. Input Maximum load: 200 mA (internal thermister trip current) Terminal capacities: Each terminal will accommodate 1 x 4mm2, or 2 x 2. 5mm2, 3 x 1. 5 solid conductors Physical Ambient operating temperature: ­5°C to +40°C IP rating: IP4X Max. installation altitude: 2000 metres Top access terminals make wiring quicker and easier Only one size of screwdriver required for installation Terminal screws supplied `backed out' and held captive within the terminal moulding I White printed terminal markings on grey rear mouldings for clearer identification Front plate fixing screws retained on rear case moulding I I Installation Shaver socket outlets may be wall or bench mounted. Non-isolated, fused, shaver socket outlets must never be installed in any location subject to splashes, condensation or damp conditions. For installation in any other room where a wash basin or shower cubicle is installed then refer to BS7671 IEE wiring regulations. Dimensions (mm) 86 9 shavers only 86 200 - 250V ac fuse 60. 3 20 Box types Flush mounting 861 ZIC minimum metal mounting box depth is 25mm K2140 32mm deep Cable Management Logic Plus socket outlets can be mounted in a variety of MK trunking systems. [. . . ] See MK catalogue for further details. Flush mounting ©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric. co. uk www. mkelectric. co. uk Edition 06-02 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MK ELECTRIC LOGIC PLUS SHAVER SOCKET OUTLET




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MK ELECTRIC LOGIC PLUS SHAVER SOCKET OUTLET will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.