User manual MK ELECTRIC LOGIC PLUS PLATESWITCHES DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MK ELECTRIC LOGIC PLUS PLATESWITCHES. We hope that this MK ELECTRIC LOGIC PLUS PLATESWITCHES user guide will be useful to you.


MK ELECTRIC LOGIC PLUS PLATESWITCHES DATASHEET: Download the complete user guide (315 Ko)

Manual abstract: user guide MK ELECTRIC LOGIC PLUS PLATESWITCHESDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] TECHNICAL DATA SHEET Logic Plus Plateswitches 1:3 Logic PlusTM Plateswitches PRODUCT RANGE 10A, 1 gang, single pole, 2 way, wide rocker plateswitch 10A, 2 gang, single pole, 2 way, wide rocker plateswitch 10A, 3 gang, single pole, 2 way, wide rocker plateswitch PRODUCT RANGE 20A, 1 gang, single pole, 1 way, plateswitch 20A, 1 gang, single pole, 2 way, plateswitch 20A, 2 gang, single pole, 2 way, plateswitch 20A, 3 gang, single pole, 2 way, plateswitch 20A, 4 gang, single pole, 2 way, plateswitch 20A, 1 gang, intermediate, plateswitch 20A, 1 gang, double pole, 1 way, plateswitch 20A, 2 gang, double pole, 1 way, plateswitch 20A, 1 gang, single pole, 2 way, wide rocker plateswitch 20A, 2 gang, single pole, 2 way, wide rocker plateswitch 20A, 3 gang, single pole, 2 way, wide rocker plateswitch Description Logic Plus plateswitches are designed to blend in with the decor, whilst complementing a wide range of other Logic Plus accessories. [. . . ] For 3 gang applications using a 25mm deep box simplifies wiring. K4781 WHI K4782 WHI K4783 WHI K4870 D2 WHI K4871 D2 WHI K4872 D2 WHI K4873 D2 WHI K4874 D2 WHI K4875 D2 WHI K4867 WHI K4868 WHI K4781 D2 WHI K4782 D2 WHI K4783 D2 WHI 10A, 1 gang, single pole, intermediate wide rocker plateswitch K4785 WHI 10A, 1 gang, single pole, 1 way plateswitch 10A, 1 gang, single pole, 2 way plateswitch 10A, 2 gang, single pole, 2 way plateswitch 10A, 3 gang, single pole, 2 way plateswitch 10A, 4 gang, single pole, 2 way plateswitch 10A, 1 gang, intermediate, plateswitch 10A, 1 gang, double pole, 1 way plateswitch 10A, 1 gang, single pole, plateswitch bell symbol 10A, 1 gang, single pole, push switch `press' legend 10A, 6 gang, single pole, 2 way plateswitch 10A, 1 gang, single pole, 2 way architrave switch 10A, 2 gang, single pole, 2 way architrave switch 10A, 1 gang, single pole, architrave bell symbol 10A, 1 gang, single pole, architrave `press' legend Neon locator K4870 WHI K4871 WHI K4872 WHI K4873 WHI K4874 WHI K4875 WHI K4876 WHI K4878 B WHI K4878 P WHI K4879 WHI 20A, 1 gang, single pole, intermediate, 2 way, wide rocker plateswitch K4785 D2 WHI 20A, dual switch 20A, dual switch with neon K5208 WHI K5207 WHI Features K4841 WHI I K4842 WHI K4848 B WHI K4848 P WHI K3041 Two way switches can be wired as one or two way All products clearly printed with BS Nos. , ratings, etc Matching Grid switches available in 10 or 20A ratings 3mm contact gap I I I Positive switch action Top access, backed out and captive terminal screws Neon locator available making switch easy to find in darkened rooms I I I ©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric. co. uk www. mkelectric. co. uk Edition 06-02 TECHNICAL DATA SHEET Logic Plus Plateswitches 2:3 Dimensions (mm) 1 gang 85 2 gang 85 3 gang 85 85 85 60. 3 85 60. 3 85 85 60. 3 85 60. 3 85 85 60. 3 85 12 60. 3 12 TECHNICAL SPECIFICATION Electrical Voltage rating: 250V a. c. 50Hz 4 gang 146 6 gang 146 85 85 Current rating: 10 amps ­ no derating when used on fluorescent or inductive loads 20 amps ­ no derating when used on fluorescent or inductive loads Terminal capacity: All products ­ 4 x 1mm2 4 x 1. 5mm2 3 x 2. 5mm2 2 x 4mm2 1 x 6mm2 Contact gap: 3mm nominal Physical Operating temperature: ­5°C to +40°C) IP rating: IP4X Max. installation altitude: 2000 metres Operational testing (all plateswitches): tested to 100, 000 operations for mechanical life tested to 30, 000 operations at 10 amp rating tested to 10, 000 operations at 20 amp rating 120. 6 12 120. 6 12 1 gang architrave 32 2 gang architrave 32 Sectional drawings show the furthest projections from the back of the frontplate (wall surface). 60. 3 Box types Flush All 1, 2 and 3 gang switches 3995 ZIC 862 ZIC 3921 ZIC 3922 ZIC Surface K2160 WHI K2161 WHI K2151 WHI K2152 WHI 85 120. 6 146 12 12 Standards and approvals All Logic Plus plateswitches comply with BS 3676: Part 1, 1989. Neon locator, BS 5733: 1995. 4 and 6 gang switches 1 gang architrave switch 2 gang architrave switch Cable Management Logic Plus plateswitches can be mounted in a variety of MK trunking systems. [. . . ] See MK catalogue for further details. ©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric. co. uk www. mkelectric. co. uk Edition 06-02 TECHNICAL DATA SHEET Logic Plus Plateswitches 3:3 Wiring Diagrams One-way switching Common L N L1 Lamp/s Two-way switching Common L2 Two-way switches L2 Common L N L1 L1 Lamp/s Dotted lines show alternative switch positions Two-way switching 3 wire control Common L2 Two-way switches L1 Common SW. L N Lamp/s L1 L2 L Dotted lines show alternative switch positions Two-way plus intermediate switching Common Two-way L2 switch L1 L2 Intermediate switch L1 Common Two-way L2 switch L N Lamp/s L1 Dotted lines show alternative switch positions Two-way plus intermediate switching 3 wire control Common L1 L1 Two-way L2 switch L2 Intermediate switch L1 Common Two-way L2 switch SW. L N Lamp/s L Dotted lines show alternative switch positions ©2002 MK Electric Limited The Arnold Centre, Paycocke Road, Basildon, Essex SS14 3EA, United Kingdom Tel: +44 (0)1268 563720 Fax: +44 (0)1268 563064 email: more@mkelectric. co. uk www. mkelectric. co. uk Edition 06-02 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MK ELECTRIC LOGIC PLUS PLATESWITCHES




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MK ELECTRIC LOGIC PLUS PLATESWITCHES will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.