User manual MINOLTA CA-210 BROCHURE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MINOLTA CA-210. We hope that this MINOLTA CA-210 user guide will be useful to you.


MINOLTA CA-210 BROCHURE: Download the complete user guide (2286 Ko)

Manual abstract: user guide MINOLTA CA-210BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Contrast Inspection / Adjustment Photo shows Universal Measuring Probe FASTER · The luminance and chromaticity of display can be measured as fast as 20 times per second (maximum), enabling faster Gamma measurement. EASY TO USE · The measurement position can be easily confirmed by pointing function. · Short measuring distance of 30 mm enables compact measuring system. · Precise measurement can be obtained without the influence of the outside light by short measuring distance and the rubber hood (standard accessory). [. . . ] IEC 61747-6, which defines the measurement method for LCDs, specifies that the viewing angle of the measuring instrument for evaluating LCDs should be within 5°. (The viewing angle is shown by 1, 2, 3 and 1, 2, 3. ) The CA-210 has a viewing angle of 5°, and so meets the requirements of the IEC standard. For a conventional measuring instrument, when the measuring head has been set so that the measurement axis is perpendicular to the surface of the emitting surface of the measurement subject, differences in the measurement position do not result in great differences in the viewing angle itself (shown as 1, 2, 3 in the figure), but if we look at the incident angle relative to the normal to the emitting surface (shown as a dotted line in the figure), we see that the maximum angles (shown as '1 and '3 in the diagram) are very different. At the edges of the measurement area, light from far outside the viewing angle is received. By using a special optical system in the CA-210, the angle of the received light is symmetrical about the normal to the emitting surface for every point within the measuring area (27 mm). Since the viewing angle of the CA-210 is 5°, the light received would be only the light within ±2. 5° relative to the normal to the emitting surface (shown as a dotted line in the figure). Measurement position and incident angle of conventional instrument '1 1 2 3 '3 Measurement position and incident angle of CA-210 1 2 3 System Diagram Muli-Probe (Optional) 4-Probe Expansion Board CA-B14 (Optional) PC (Commercially available) PC-AT compatible Universal Measuring Probe CA-PU12 (2 m) CA-PU15 (5 m) Small Universal Measuring Probe CA-PSU12 (2 m) CA-PSU15 (5 m) LCD Flicker Measuring Probe CA-P12 (2 m) CA-P15 (5 m) Small LCD Flicker Measuring Probe CA-PS12 (2 m) CA-PS15 (5 m) (Hood and Lens Cap included) Standard Hood for CA-210 CA-H10(Standard) or Small Hood for CA-210 CA-HS10(Standard) CA-210 PC Software for Color Analyzer CA-SDK(Standard) Select the probe among the following four types. Universal Measuring Probe CA-PU12 (2 m) CA-PU15 (5 m) Small Universal Measuring Probe Standard Lens Cap for CA-210 CA-PSU12 (2 m) CA-H11(Standard) CA-PSU15 (5 m) or LCD Flicker Measuring Probe CA-P12 (2 m) Small Lens Cap for CA-210 CA-P15 (5 m) CA-HS11(Standard) Small LCD Flicker Measuring Probe CA-PS12 (2 m) CA-PS15 (5 m) AC Power Cord (Standard) LCD Flicker Measuring Probe is applied to the "Flicker measuring function". Because of this it is not able to measure the display whose emission intensity fluctuates in single frame scanning period. DISPLAY COLOR ANALYZER CA-210 LCD Flicker Measuring Probe Small LCD Flicker Measuring Probe Same model as CA-210 measuring probes sold until May 2003. Select the probe among the following four types. LCD Flicker Measuring Probe LCD Flicker Measuring Probe (Measurement area 27 mm / Cable length: 2 m) (Measurement area 27 mm / Cable length: 5 m) (Measurement area 10 mm / Cable length: 2 m) (Measurement area 10 mm / Cable length: 5 m) CA-P12 CA-P15 Small LCD Flicker Measuring Probe CA-PS12 Small LCD Flicker Measuring Probe CA-PS15 Up to five probes can be connected to a single main body. Universal Measuring Probes, Small Universal Measuring Probes, LCD Flicker Measuring Probes and Small LCD Flicker Measuring Probes can be connected simultaneously to a single main body. (To connect multiple probes, the optional four-point extension board (CA-B14) is necessary. ) CRT COLOR ANALYZER Select the probe among the following four types. CA-100Plus Measuring Probe High luminance Measuring Probe Please request a CA-100Plus catalog for further information. Measuring Probe Measuring Probe (Cable length: 5 m) (Cable length: 2 m) CA-P02 CA-P05 CA-PH02 CA-PH05 High luminance Measuring Probe (Cable length: 2 m) (Cable length: 5 m) High luminance Measuring Probe Up to five probes can be connected to a single main body. Measuring Probes and High luminance Measuring Probes can be connected simultaneously to a single main body. (To connect multiple probes, the optional four-point extension board (CA-B04) is necessary. ) Applicability of CA series for different display types This table is based on the most popular method for controlling emission intensity for each display type. (1) Measurements of displays using certain control methods are not possible. [. . . ] 5 points(Use 4-Probe Expansion Board CA-B14) Multi-point Measurement SDK software (supplied as standard accessory) Software Operating temperature/humidity range Temperature : 10 to 28°C; relative humidity 70 % or less with no condensation Luminance change : ±2 % ±1 digit of reading for white Chromaticity change ±0. 002 for white, ±0. 006 for monochrome from reading of Konica Minolta's standard LCD1, 160. 0 cd/m2, with 23°C 40 % Storage temperature/humidity range 0 to 28°C : relative humidity 70 % or less with no condensation 28 to 40°C : relative humidity 40 % or less with no condensation 100 ­ 240 V~, 50­60 Hz, 50 VA Input voltage range Main body: 340 (W) × 127 (H) × 216 (D) mm, Main body: 340 (W) × 127 (H) × 216 (D) mm, Main body: 340 (W) × 127 (H) × 216 (D) mm, Main body: 340 (W) × 127 (H) × 216 (D) mm, Size Probe: 49 × 204 mm Probe: 49 × 232 mm Probe: 49 × 204 mm Probe: 49 × 232 mm Main body: 3. 58 kg, Probe: 520 g Weight Main body: 3. 58 kg, Probe: 540 g Main body: 3. 58 kg, Probe: 520 g Main body: 3. 58 kg, Probe: 540 g 1 : The chromaticity and luminance are measured under Konica Minolta's condition (standard LCD(6500 K, 9300 K) is used). 2 2 : The luminance for monochrome is measured when the reading of luminance for white is 160 cd/m . 3 : Measurement of flicker (JEITA method) is supported by SDK software. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MINOLTA CA-210




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MINOLTA CA-210 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.