User manual MIELE KM 81-2

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE KM 81-2. We hope that this MIELE KM 81-2 user guide will be useful to you.


MIELE KM 81-2 : Download the complete user guide (837 Ko)

Manual abstract: user guide MIELE KM 81-2

Detailed instructions for use are in the User's Guide.

[. . . ] Operating instructions Gas cooktop KM 81-2 CANADIAN GAS ASSOCIATION R APROVED @]äö M. -Nr. 04 426 731 Description of the appliance Description of the appliance KM 81-2 2 Description of the appliance Description of the appliance KM 81-2 Data plate Because the data plate is no longer visible once the appliance has been built in, a 2nd data plate is supplied which should be placed into the space provided on page 16 of these instructions under After Sales Service. b Trivet c Wok/pan support d Small burner cap eLarge burner cap f Burner ring g Large burner cap base h Ignitor i Cable for connection to electrical supply approx. 3. 6 ft (1. 10 m) long. Special accessories Special accessories are available from your Miele Dealer or from the Spare Parts Department. Stainless steel cover-EA 80 A stainless steel cover is available for the KM 81-2 cooktop. [. . . ] When contacting the Service Department, please quote the Model and Serial No. of the appliance, both of which can be found on the data plate. Space for enclosed data plate 17 Electrical connection The automatic ignition requires connection to an a. c. These appliances are factory equipped with a power supply cord ready for connection to an electrically grounded socket which complies with your local electrical codes or with the: National Electical Code ANSI/NFPA No. Ensure that the reeptacle is so positioned that it is easily accessible when the appliance is built in. ]öElectrical connection ]ö Technical data CDN / USA Total connected load . 1. 1 m (3 ft) Check that data given on the data plate under the appliance complies with the main voltage. Do not cut or remove the grounding prong from this plug. 18 Electrical connection Electrical connection AUS Electrical connection of the appliance should be undertaken by a suitably competent person in strict accordance with national and local safety regulations. For extra safety it is advisable to install a residual current device (RCD), with a trip current of 30 mA. The appliances are supplied with a mains cable for connection to single phase 240 V, 50 Hz supply. The On-Off switch should be easily accessible after the appliance has been built-in. Electrical connection NZ The appliances are supplied with a mains cable for connection to single phase 230 V, 50 Hz supply. Important: The wires in the mains lead are coloured in accordance with the following code: Green/yellow = earth Blue = neutral Brown = live @ä @äElectrical connection As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: The wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the letter E or by the earth symbol z or coloured green or green and yellow. The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black. The wire which is coloured brown must be connected to the terminal which is marked with the letter A or coloured red. WARNING THIS APPLIANCE MUST BE EARTHED. Technical data AUS (NZ) Total connected load . 1. 10 m If the connection cable needs replacing, only use cable with at least 3 x 1 mm2. 19 ]ö Gas connection ]ö Gas connection This appliance must be installed with a separate shut-off valve and a gas pressure regulator. Both shut-off valve and pressure regulator must be easily accessible to the consumer. This appliance and its individual shut-off valve must be disconnected from the gas supply during any pressure testing of that system at test pressures in excess of 1/2 PSI (3. 5 kPa). This appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSI (3. 5 kPa). Any pipe connections must be made using a thread sealant approved for gas connections. Failure to correctly install these items could lead to a gas leak and subsequent explosion. For convenience, an approved type of flexible stainless steel gas pipe (accordion type) may be installed between the adapter and the regulator. If an elbow adapter is necessary for your particular installation, a customized one ­ can be obtained free of charge from the Miele parts department (USA). [. . . ] When set at "high", the inner cone of the gas flame should be clearly visible. 36 Conversion to alternative types of gas The appliance is set up for natural gas (NG). When converting to alternative types of gas, the components as listed below have to be changed: gas type New Zealand Australia @ä Conversion to alternative types of gas @ä burner jet in mm N° 34 2. 0 N° 7 1. 12 N° 7 1. 12 adj. screw of control 0. 40 regulator label for gas type NG small NG large small LPG Propane LPG Remarks -- large large small No 1 0. 88 alt. 0. 90 0. 23 No 2 0. 52 0. 23 No 2 0. 52 Conversion LPG LPG Changes for LPG Propane: jets, adjusting screws, regulator, Propane label. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE KM 81-2




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE KM 81-2 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.