User manual MIELE DA 92 VENTILATION HOOD OPERATING MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 92 VENTILATION HOOD. We hope that this MIELE DA 92 VENTILATION HOOD user guide will be useful to you.


MIELE DA 92 VENTILATION HOOD OPERATING MANUAL: Download the complete user guide (856 Ko)

Manual abstract: user guide MIELE DA 92 VENTILATION HOODOPERATING MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] The manufacturer cannot be held responsible for damages caused by improper use of the hood. Improper use of the appliance can lead to personal injury and material damage. READ AND SAVE THESE INSTRUCTIONS This appliance is designed to vent cooking smoke and odors only. Be certain your appliance is properly installed and grounded by a qualified technician. [. . . ] 1 indicator 2 indicators 3 indicators 4 indicators = = = = less than 25 % less than 50 % less than 75 % less than 100 % This information will remain stored in memory in the event of a power failure. ^ To do this, press the charcoal filter button for about 3 seconds. Stainless steel Stainless steel surfaces can be cleaned using a non-abrasive stainless steel cleaner. To help prevent resoiling, a conditioner for stainless steel can also be used. Stainless steel colored controls These controls may become discolored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls. Cleaning the casing , Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. ^ All external surfaces and controls can be cleaned with warm water and liquid dish soap applied with a soft sponge. Avoid: ­ cleaning agents containing soda, acids or chlorides, ­ abrasive cleaning agents e. g. pot scourers or sponges which have been previously used with abrasive cleaning agents. These will damage the surface. 16 Cleaning and Care Grease filters The reusable metal grease filters remove solid particles from the vented kitchen air (grease, dust, etc). Depending on the detergent, cleaning the grease filters in a dishwasher may cause permanent discoloration of the filter surface. ^ While the filters are removed, clean any dirt or grease from the filter casing to prevent the risk of fire. 4 screws 3. 9 x 7. 5 mm for securing the chimney and the chimney extension 2 M 6 locking nuts for securing the motor assembly. 12 large headed screws 5 x 40 mm for securing the retaining plates and the canopy. (S8 wall anchors included in the packaging are not for use in USA / CDN. ) 25 Plywood backing The majority of the weight of the installed ventilation system will be supported by retaining plate A. If studs are not available in the required locations, a plywood backing (min. 1 /2" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage. ^ Hold retaining plate A against the wall so that the marks are visible through the holes of the plate (see "Installation / Retaining plate A"). Draw a line around the plate's perimeter, then set aside the plate. ^ Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of plate "A". ^ Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder. Be careful not to damage any wiring or plumbing that may be located behind the wall. [. . . ] For air extraction, the vents are not required and are covered by the chimney. 36 Installation ^ Screw the extension piece firmly to the upper retaining plate using two 3. 9 x 7. 5 mm screws. ^ Cover the screws with the supplied cap covers. ^ Only for recirculation: With the slats pointing downwards, install the recirculation vents through the extension piece and into the diverter. Recirculation Air extraction ^ Pull the chimney extension slightly outwards and snap over the upper retaining plate B. When installing for recirculation, ensure that the vents are positioned so they line up with the diverter. 37 Installation Attaching the chimney ^ Remove the protective foil from the chimney. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 92 VENTILATION HOOD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 92 VENTILATION HOOD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.