User manual MIELE DA 72 VENTILATION HOOD OPERATING MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 72 VENTILATION HOOD. We hope that this MIELE DA 72 VENTILATION HOOD user guide will be useful to you.


MIELE DA 72 VENTILATION HOOD OPERATING MANUAL: Download the complete user guide (955 Ko)

Manual abstract: user guide MIELE DA 72 VENTILATION HOODOPERATING MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Improper use of the appliance can lead to personal injury and material damage. READ AND SAVE THESE INSTRUCTIONS This appliance is designed to vent cooking smoke and odors only. Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. [. . . ] ­ to change the number of hours counted by the grease filter timer (see "Operation / Reprogramming the grease filter timer"). 9 Functional description The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filters and directed outside. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur. When the hood is turned on, the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside. 10 Operation Main power switch Intensive setting Level "4" (yellow indicator) should be used for a short period when frying or cooking food with a strong aroma. If the appliance is not going to be used for a long period of time (e. g. while vacationing) turn the appliance off by pressing the main power switch to "0". The next time it is turned on, the hood will operate at the level previously used. Factors such as narrow duct diameter and bends will affect this value. Level 1 operates at 40% capacity Level 2 operates at 60% capacity Level 3 operates at 80% capacity Level 4 operates at 100% capacity Turning on the fan Delayed Shut Down If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. ^ Press the On/Off button. The On/Off indicator lights. Selecting the power level ^ Press the Delayed Shut Down button while the fan is still running. Press once = 5 minute delay (left indicator lights) Press twice = 15 minute delay (right indicator lights) To cancel the Delayed Shut Down feature press the button again. ^ Use the _ buttons to select the desired power level. ^ Pull the old bulb, d, out of its socket and replace it with a new one. The glass is specially made to filter harmful light rays. 17 After Sales Service In the event of a fault which you cannot correct yourself please contact: ­ Your Miele Dealer or ­ The Miele Technical Service Department USA CDN 1-800-999-1360 techserv@mieleusa. com 1-800-565-6435 service@miele. ca When contacting the Technical Service Department, please quote the model and serial number of your appliance. These are shown on the data plate which is visible when the grease filter is removed. 18 Installation instructions Table of Contents Caring for the environment Structural support Electrical data Appliance dimensions DA 210-2 . 25 Installation Air extraction 20 Caring for the environment Disposal of packing material The cardboard box and packing materials protect the appliance during shipping. Danger of suffocation! Disposal of an old appliance Old appliances may contain materials that can be recycled. Please contact your local recycling authority about the possibility of recycling these materials. Before discarding an old hood, unplug it from the outlet and cut off its power cord to prevent hazards. 21 Structural support The ceiling mounting plate will support the weight of the hood. This ceiling plate must be attached to rigid structural framing that is supported in its entirety by the ceiling joists, or to the ceiling joists directly. Do not attach the plate directly to the ceiling by using anchors, mollies or toggle bolts. 22 Electrical data All electrical work should be performed by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed. [. . . ] Select the hole providing the shortest route for the power cable b to reach the power terminal located at the top of the hood's chimney. ^ Drill four 3/16" (5 mm) holes in the ceiling. The S10 wall anchors included in the packaging are not for use in USA/CDN. Be certain that the ceiling is stable enough to support the hood. 27 Installation ^ Secure the ducting to the mounting plate using a hose clip. ^ Insert the short edge of the two spring clips into their slots from below and pivot them 90° so that the tab faces the center of the mounting brake. ^ Insert the four countersunk screws M 6 x 20 into the recessed holes from above. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 72 VENTILATION HOOD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 72 VENTILATION HOOD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.