User manual MIELE DA 65 VENTILATION HOOD OPERATING MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 65 VENTILATION HOOD. We hope that this MIELE DA 65 VENTILATION HOOD user guide will be useful to you.


MIELE DA 65 VENTILATION HOOD OPERATING MANUAL: Download the complete user guide (172 Ko)

Manual abstract: user guide MIELE DA 65 VENTILATION HOODOPERATING MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] appliance, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. If there is any doubt, have the electrical system of the house checked by a qualified electrician. ~ b) Before servicing or cleaning the ~ This appliance is intended for ~ This appliance complies with current safety requirements. [. . . ] This is because accumulated grease will harden over time, making cleaning difficult. ^ Press the Delayed Shut Down 5 ¢15 and filter button l at the same time. The indicator for the grease filter timer l and one of the power level indicators will flash. The 1 to IS indicators show the programmed time: Indicator 1 = 20 hours Indicator 2 = 30 hours Indicator 3 = 40 hours Indicator IS = 50 hours ^ Press the "­" symbol to select a shorter operating time or the "+" symbol for a longer one. If the procedure is not stored within 4 minutes, the hood will automatically default to the original setting. 13 Operation Activating and reprogramming the Charcoal filter timer (in recirculation mode) The charcoal filter is needed for recirculation mode. Before using the hood in recirculation mode, the charcoal filter timer must be programmed. The 1 to IS indicators show the programmed time: Indicator 1 = 120 hours Indicator 2 = 180 hours Indicator 3 = 240 hours Indicator IS = Deactivated ^ Press the ­ symbol to select a shorter operating time, or the + symbol to select a longer operating time. If the procedure is not stored within 4 minutes, the hood will automatically default to the original setting. Reading the filter operating hours counter To check the percentage of time set already used ^ Press the On/Off control s to switch the fan on. ^ Press and hold the filter button l : ­ Once, to read the Grease filter operating hours. The number of flashing "­/+" indicators show the percentage of programmed hours that have been used. 6 seconds, until only the 1 is flashing. 17 Cleaning and Care Active charcoal filter In recirculation mode an active charcoal filter must be used in addition to the grease filters. The active charcoal filter will be replaced in the canopy above the grease filters. ^ To install or replace the charcoal filter, the grease filters must first be removed as described in the previous section. Replace the active charcoal filter when the charcoal filter indicator lights, at least every 6 months or when they no longer absorb odors efficiently. Resetting the charcoal filter timer After replacing reset the charcoal filter operating hours timer. ^ With the fan running, press the charcoal filter button l twice and hold it for approx. If the charcoal filter is replaced before the timer has reached its maximum: ^ Press the charcoal filter button twice l and hold it for approx. 6 seconds, until only the 1 is flashing. ^ Slide the charcoal filter into the rear of the filter frame. Before using: ^ Program the charcoal filter timer, see "Operation / Activating and reprogramming the charcoal filter timer". 18 Cleaning and Care Changing the light bulbs , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, and can burn your hands. Do not attempt to change the bulbs until they have had sufficient time to cool. ^ Using a cloth or glove, insert the new halogen bulb (type 12 V, 20 W, G4). [. . . ] Ensure that the wall can support the weight. Installation instructions 31 Air extraction , WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 65 VENTILATION HOOD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 65 VENTILATION HOOD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.