User manual MIELE DA 6480

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 6480. We hope that this MIELE DA 6480 user guide will be useful to you.


MIELE DA 6480 : Download the complete user guide (1534 Ko)

Manual abstract: user guide MIELE DA 6480

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and Installation Instructions Downdraft Ventilation System DA 6480, DA 6490 DAG 500, DAG 1000 To prevent accidents and appliance damage, read these instructions before installation or use. en - US, CA M. -Nr. 37 2 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Keep these operating instructions in a safe place and pass them on to any future user. Read these Instructions carefully before installing or using the Ventilation System. Use the appliance only for its intended purpose. , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Use this appliance only in the manner intended by the manufacturer. [. . . ] Please contact your local recycling center about the possibility of recycling these materials. Before discarding an old appliance, disconnect it from the electrical supply and cut off the power cord to prevent it from becoming a hazard. Ensure that any plastic wrappings, bags, etc. , are disposed of safely and kept out of the reach of babies and young children. Danger of suffocation! , DANGER 19 Appliance dimensions 20 Appliance dimensions a DAG 500 Internal blower The blower box can be mounted in such a way that the vent collar is aligned to the left, the right, downwards or towards the rear, as desired. b Connection plate when using the DAG 1000 external blower The blower or the connection plate can also be mounted in the same position on the rear of the appliance. Exhaust duct connection diameters DA 6480, 6490 with internal blower DAG 500:. 10" C (254 mm) 21 Appliance dimensions Cabinet dimensions 22 Appliance dimensions Exhaust air ducting using the DAG 500 internal blower, installed on the front of the appliance [vent duct 6" C (150 mm)]: a to the left or right, b downwards, c to the rear. If the blower is being installed at the rear of the appliance, a cut-out must be made in the rear of the cabinet or wall where it will be mounted and the appropriate clearances must be maintained behind the cabinet. d Feed the power cord and control cable when using an external blower downwards or to the rear. e Using the DAG 1000 external blower, install exhaust ducting to the rear (vent duct 10" C (254 mm)). If installing the exhaust ducting to the front, appropriate clearances must be maintained in the cabinet. a) Cooktop overhang b) Minimum width of the cooktop: DA 6480: 28" (711 mm) DA 6490: 34" (864 mm) ­ The specified dimensions minimum cut-out dimensions must be observed. ­ If an oven or stove is installed before the ventilation system, read the associated installation instructions. Note all installation dimensions and guidelines regarding ventilation systems. ­ Be aware of kitchen cabinets, back splashes and/or racks in the area of the ventilation system and the cooktop. ­ Make sure that any required minimum distance between the front edge of the countertop and the front edge of the cooktop is maintained. ­ If there is a drawer in the way, it must be shortened or removed. The front panel of the drawer could also be installed to permanently cover the drawer cut-out. 23 Appliance dimensions Installation using the DAG 500 internal blower DAG 500 mounted in front of the exhaust system. DAG 500 mounted behind the exhaust system. Note that the blower must be accessible to install the venting ductwork. 24 Appliance dimensions Installation using the DAG 1000 external blower connection plate Exhaust air ducting to the front. Exhaust air ducting to the rear. Note that the back must be accessible for the installation of the vent duct. 25 Installation The ventilation system is installed directly behind the cooktop. For easiest installation, install the ventilation system first, then the cooktop. The ventilation system must not be installed in an area where there are strong drafts, for instance near windows, doors, etc. Before installation, please read the "Appliance dimensions" and "Important safety instructions". [. . . ] ­ Where the ductwork is horizontal, it must slope away from the ventilation system at least 1/8" per foot (1 cm per meter) to prevent condensation dripping into the appliance. ­ If the exhaust is ducted into an unused flue, the air must be expelled parallel to the flow direction of the flue. *10" (254 mm) with exterior-mounted vent motor. 35 Air extraction Condensate trap Never connect a ventilation system to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting the ventilation system to an existing, inactive chimney or vent flue. where temperature variations exist, it may need to be insulated to reduce condensation. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 6480




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 6480 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.