User manual MIELE DA 262 BUILT-IN HOOD OPERATING MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 262 BUILT-IN HOOD. We hope that this MIELE DA 262 BUILT-IN HOOD user guide will be useful to you.


MIELE DA 262 BUILT-IN HOOD OPERATING MANUAL: Download the complete user guide (905 Ko)

Manual abstract: user guide MIELE DA 262 BUILT-IN HOODOPERATING MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] 0 - Light off l - Light on h - Grease filter retainer This is used for securing or releasing the grease filter f from the cooker hood. i The control panel can either - be fitted with an aluminium front facia panel, available from Miele, - be fitted with a lightshield from the kitchen furniture programme, or - be installed without either of the above, but with cover caps (supplied for fitting at each end). c - Slide switch for the fan m This is used to switch the fan on and off. 0 - Fan off l - Fan on 3 Contents Contents Description of the appliance . 24 4 Help to protect our environment Help to protect our environment Disposal of packaging The transport and protective packing is mostly manufactured from the following re-usable materials: . Rather than just throwing these materials away, please take them to the nearest local authority collection point for specific waste. [. . . ] The cooker hood will operate at the setting the power selector is set to. Select a power setting strong enough to clear the air: 1 2 3 IS or push the deflector plate in. Setting 1-2 = for normal operation Setting 3-Intensive setting (IS) = for removing heavy cooking odors Switch on the cooktop illumination switch if required. 9 Cleaning and care Cleaning and care Before any cleaning or maintenance work, the extractor must be disconnected from the mains supply (switch off at the wall socket and remove plug or the fuse). Cleaning The cooker hood housing may be cleaned using hot water to which a little mild detergent has been added. Grease filters Re-usable metal grease filters are builtin which remove solid particles (oil, dust, etc. ) from the kitchen vapors, preventing soiling of the cooker hood. The grease filters should be cleaned regularly to ensure a trouble free operation of the extractor fan, at least every 1 or 2 months, or when they are visibly saturated or no longer effective. To remove the grease filters push the filter holder retainers towards the middle. DA 272 i, DA 292 i only: Press the clips at the side in using a blunt instrument and remove the retainers. in a dishwasher: place the filters with the short side upright in the lower basket, ensuring the spray arm is not obstructed. Important The wires in the power supply cable are colored in accordance with the following code: Green = ground Black = live White = neutral WARNING THIS APPLIANCE MUST BE GROUNDED For USA only: The cooker hoods are supplied with a 5 ft power supply cable ready for connection to an a. c. , single phase, 120 V / 60 Hz supply. Important The wires in the power supply cord are colored in accordance with the following code: Green/yellow = ground Blue = neutral Brown = live As the colors of the wires in the power supply cord of this appliance may not correspond with the colored markings identifying the terminals in your junction box, proceed as follows: The wire which is colored green and yellow must be connected to the terminal junction box which is marked by the letter E, or by the earth symbol z or colored green or green and yellow. The wire which is colored blue must be connected to the terminal which is marked with the letter N or colored white. The wire which is marked brown must be connected to the terminal which is marked with the letter L or colored black. WARNING THIS APPLIANCE MUST BE GROUNDED 13 Technical data Technical data DA 262 i Total rated load Light Voltage Frequency Fuse rating Connection cable with plug Maximum air throughput: Air extraction 225 W 15 W 120 V 60 Hz 15 A 5 ft (1, 5 m) DA 272 i 223 W 13 W 120 V 60 Hz 15 A 5 ft (1, 5 m) DA 292 i 235 W 16 W 120 V 60 Hz 15 A 5 ft (1, 5 m) 90-325 CFM (150-550 m3/h) 50-240 CFM (80-350 m3/h) 90-325 CFM ( 150-550 m3/h) 50-240 CFM (80-350 m3/h) 90-325 CFM (150-550 m3/h) 50-240 CFM (80-350 m3/h) Air recirculation 14 Installation Installation For installing the cooker hood, a cabinet is required. The minimum cabinet width required for each model is given below: ­ DA 262 i = 600 mm (23 5/8") ­ DA 272 i = 700 mm (21 9/16") ­ DA 292 i = 900 mm (35 7/16") The exhaust connection must be made by a suitably qualified and competent person. The distance between the top of the cooktop and the bottom of the cooker hood should be at least: 45 cm (18") above electric cooktops 65cm (26") above gas cooktops. Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. 15 Installation Installation Appliance dimensions Wall unit dimensions A: DA 262 i = 560; DA 272 i = 660; DA 292 i =860 B: DA 262 i = 595; DA 272 i = 695; DA 292 i =895 5 15 /16 415 /16 1313/16 25/16 65/8 A: DA 262 i = 562-568 = 22 1/8" - 22 3/8" DA 272 i = 662-668 = 26 1/16" - 26 5/16" DA 292 i = 862-868 = 33 15/16" - 34 3/16" B: DA 262 i = 600 = 23 5/8" DA 272 i = 700 = 27 5/8" DA 292 i = 900 = 35 1/2" 170-235 = 6 3/4" - 9 1/4" 135 = 5 3/8" 430 = 17" 110 = 4 11/16" 20 = 3/4" 285-350 = 11 1/4" - 13 7/8" 2 107 /16 A: DA 262 i = 22 1/16''; DA 272 i = 26''; DA 292 i =33 7/8'' B: DA 262 i = 23 5/8''; DA 272 i =27 9/16''; DA 292 i=35 7/16'' 13/16 The dividing wall must be removable to enable the cooker hood to be adjusted for height and depth. 515/16 107/16 max. 1615/16 * plus depth of control panel 16 Installation Installation Building in Take the dividing wall out of the wall unit. Push the brackets into the slots on the sides of the cooker hood. 19 mm ( 3/4 ") thick side walls: Secure the support tracks to both interior walls of the unit using two 3, 5 x 16 mm ( 5/8 ") screws, position as illustrated. 16 mm ( 5/8 ") thick side walls: Fasten the brackets in place on the cooker hood using the M 6 x 10 mm hexagonal bolts and washers. The thickness of the side walls must be taken into account. 17 Installation Installation Lift the cooker hood into the unit from below until the lugs of the brackets lie above the support tracks. Feed the air extraction or air re-circulation connector through as applicable, (see chapter "Air extraction" / "Air re-circulation"). Pull the deflector plate out to its limit and remove the grease filters. [. . . ] where there may be great variations in temperature between the different areas, the problem of sweating or condensation will need to be addressed. In addition to insulating the exhaust ducting it may also be necessary in some cases to install a suitable condensate trap to collect and evaporate any condensate which may occur. When installing a condensate trap, ensure that it is located vertically and if possible directly above the exhaust connection. Calculation of extraction ducting A pipe diameter of 125 mm (5'') should ensure trouble-free extraction up to a total pipe length of 33 m (108''). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 262 BUILT-IN HOOD




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 262 BUILT-IN HOOD will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.