User manual MIELE DA 5190 W

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 5190 W. We hope that this MIELE DA 5190 W user guide will be useful to you.


MIELE DA 5190 W : Download the complete user guide (934 Ko)

You may also download the following manuals related to this product:

   MIELE DA 5190 W INSTALLATION (1128 ko)
   MIELE DA 5190 W INSTALLATION (1128 ko)
   MIELE DA 5190 W INSTALLATION MANUAL (1128 ko)
   MIELE DA 5190 W INSTALLATION (1128 ko)
   MIELE DA 5190 W INSTALLATION MANUAL (1128 ko)

Manual abstract: user guide MIELE DA 5190 W

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and Installation Instructions Ventilation System DA 5190 W To prevent accidents and appliance damage, read these instructions before installation or use. en - US, CA M. -Nr. 36 2 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Keep these instructions in a safe place and pass them on to any future user. Read these instructions carefully before installing or using the Ventilation System. Use the appliance only for its intended purpose. , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ~ a) Use this appliance only in the manner intended by the manufacturer. [. . . ] Before using the hood in recirculation mode, the charcoal filter timer must be programmed. The lit indicator shows the programmed time: 1st indicator from the left 2nd indicator from the left 3rd indicator from the left 4th indicator from the left = 120 hours = 180 hours = 240 hours = endless ^ Use the "­/+" button to select the desired time. ^ Press the "+" and the grease/charcoal filter buttons at the same time. The blue indicator for the grease/charcoal filter and one of the "­/+" indicators will flash. If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data. 16 Cleaning and Care , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". Avoid: ­ cleaning agents containing soda, acids, chlorides or thinners, ­ abrasive cleaning agents e. g. pot scourers or sponges which have been previously used with abrasive cleaning agents, ­ limescale removers. Cleaning the casing Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. ^ All external surfaces and controls can be cleaned with a mild solution of warm water and liquid dish soap applied with a soft sponge. ^ Glass surfaces can be cleaned using glass cleaner. These will damage the surface. The following instructions for cleaning "Stainless steel" surfaces and "Stainless steel colored controls" should be followed in addition to the general "Cleaning the casing" instructions. Stainless steel Stainless steel surfaces can be cleaned using a non-abrasive stainless steel cleaner. To help prevent resoiling, a conditioner for stainless steel can also be used. Stainless steel colored controls These controls may become discolored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls. 17 Cleaning and Care Grease filter The reusable metal grease filter removes solid particles from the vented kitchen air (grease, dust, etc). Removing the grease filter The grease filter should be cleaned every 3 - 4 weeks or whenever the grease filter indicator lights red. , A dirty filter is a fire hazard. ^ To remove the grease filter pull the locking clip forward. Support the grease filter so that it does not fall onto the cooktop. 18 Cleaning and Care Cleaning the grease filter ^ By hand: use a scrub brush with a solution of warm water and mild detergent. Do not use pure detergent, aggressive all purpose cleaners, oven sprays, abrasive cleaning agents or limescale removers. ^ In a dishwasher: place the filter vertically in the lower basket, making sure that the spray arm is not blocked. Depending on the detergent, cleaning the grease filter in a dishwasher may cause permanent discoloration of the filter surface. ^ While the filter is removed, clean any dirt or grease from the interior casing to prevent the risk of fire. ^ When putting the grease filter back make sure that the locking clip is facing the cooking surface. ^ If the filter is incorrectly installed, insert a small screwdriver into the slit along its edge to disengage it from the casing. ^ After returning the grease filter, press the grease filter button for 3 seconds to reset the timer. ^ If the grease filter is cleaned before the grease filter timer has reached its maximum, the grease filter button should be pressed for 6 seconds to reset the counter to zero. 19 Cleaning and Care Active charcoal filter In recirculation mode an active charcoal filter must be used in addition to the grease filter. The active charcoal filter will be placed in the canopy above the grease filter. [. . . ] Please read and follow the "IMPORTANT SAFETY INSTRUCTIONS" to reduce the risk of personal injury. Exhaust ducting and connections Use smooth or flexible pipework made from approved non-flammable materials for exhaust ducting. To achieve the most efficient air extraction and quietest noise levels, consider the following: ­ The diameter of the ductwork should not be less than 6" (150 mm). ­ If flat ducting is used, the cross section must not be smaller than the cross section of the ventilation exhaust. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 5190 W




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 5190 W will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.