User manual MIELE DA 279-3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 279-3. We hope that this MIELE DA 279-3 user guide will be useful to you.


MIELE DA 279-3 : Download the complete user guide (638 Ko)

You may also download the following manuals related to this product:

   MIELE DA 279-3 (599 ko)

Manual abstract: user guide MIELE DA 279-3

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and installation instructions Ventilation System DA 279-3 To prevent accidents and machine damage, read these instructions before installation or use. UV M. -Nr. 05 853 690 2 Table of Contents IMPORTANT SAFETY INSTRUCTIONS Guide to the appliance Functional description Operation Main power switch . 20 After Sales Service Installation instructions 3 IMPORTANT SAFETY INSTRUCTIONS Read these Operating Instructions carefully before installing or using the Ventilation System. This appliance is intended for residential use only. The manufacturer cannot be held responsible for damages caused by improper use of the hood. [. . . ] The lit indicator shows the programmed time: 1st indicator from the left 2nd indicator from the left 3rd indicator from the left 4th indicator from the left = = = = 20 hours 30 hours 40 hours 50 hours The indicator for the charcoal filter and one of the _ indicators will flash. ^ Use the $ or & button to select the desired time. ^ Turn off the fan using the On/Off button. ^ Store the selection by pressing the charcoal filter button. ^ Press the Delayed Shut Down and charcoal filter buttons at the same time. If the procedure is not stored within 4 minutes of programming, the hood will automatically default to the "old" data. 16 Cleaning and Care Before cleaning or servicing the hood, disconnect it from the power supply by either removing the fuse, unplugging it from the outlet or manually "tripping" the circuit breaker. Stainless steel Stainless steel surfaces can be cleaned using a non-abrasive stainless steel cleaner. To help prevent resoiling, a conditioner for stainless steel can also be used. Stainless steel colored controls These controls may become discolored or damaged if not cleaned regularly. Do not use a stainless steel cleaner on these controls. Cleaning the casing Warning: Never use abrasive cleaners, scouring pads, steel wool or caustic (oven) cleaners on the hood. ^ All external surfaces and controls can be cleaned with warm water and liquid dish soap applied with a soft sponge. Avoid: ­ cleaning agents containing soda, acids or chlorides, ­ abrasive cleaning agents e. g. pot scourers or sponges which have been previously used with abrasive cleaning agents. These will damage the surface. 17 Cleaning and Care Grease filters The reusable metal grease filters remove solid particles from the vented kitchen air (grease, dust, etc). The grease filters should be cleaned every 3 - 4 weeks or whenever the grease filter indicator lights. ^ Clean the filters - by hand: use a scrub brush in warm water with a mild detergent. - in a dishwasher: place the filters vertically in the lower basket, making sure that the spray arm is not blocked. Depending on the detergent, cleaning the grease filters in a dishwasher may cause permanent discoloration of the filter surface. ^ While the filters are removed, clean any dirt or grease from the filter casing to prevent the risk of fire. When putting the grease filters back make sure that the locking clips are visible facing the cooking surface. If the filters are incorrectly installed, insert a small screwdriver into the slit along its edge to disengage it from the casing. ^ After returning the grease filters, press the grease filter button for 3 seconds to reset the timer. ^ If the grease filters are cleaned before the grease filter timer has reached its maximum, the grease filter button should be pressed for 6 seconds to reset the counter to zero. ^ To remove the grease filters press the locking clips in towards the middle of the filter. Support grease filter so that it does not fall on to the cooktop. 18 Cleaning and Care Active charcoal filter In recirculation mode an active charcoal filter must be used in addition to the grease filters. The active charcoal filter will be placed in the canopy above the grease filters. [. . . ] 26" (65 cm) is recommended for all installations to allow for optimum work space under the hood. Read the entire installation procedure and determine height (S) before beginning the installation. If the hood is fitted flush to the ceiling make sure that the remaining distance to the ceiling is not greater or less than appliance height H. (820 - 1100 mm) To fit the chimney, distance A between the top of the chimney and the ceiling must be at least 7/8" (20 mm). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 279-3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 279-3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.