User manual MIELE DA 270-4

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIELE DA 270-4. We hope that this MIELE DA 270-4 user guide will be useful to you.


MIELE DA 270-4 : Download the complete user guide (952 Ko)

You may also download the following manuals related to this product:

   MIELE DA 270-4 (671 ko)
   MIELE DA 270-4 (693 ko)

Manual abstract: user guide MIELE DA 270-4

Detailed instructions for use are in the User's Guide.

[. . . ] Operating and installation instructions Cooker hood DA 270-4, DA 270-4 EXT DA 270-4 U DA 270-4 Alu, DA 270-4 EXT Alu DA 270-4 U Alu To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time. GiWOZ M. -Nr. 33 2 Caring for the environment Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and can normally be recycled. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children. Dispose of or recycle all packaging materials safely as soon as possible. Disposal of your old appliance Electrical and electronic appliances often contain materials which, if handled or disposed of incorrectly, could be potentially hazardous to human health and to the environment. [. . . ] The indicator lamp for the control will go out. ^ Press and hold the grease filter control. One or more of the indicator lamps for the - /+ controls will flash. The number of flashing lamps shows the percentage of the operating time which has already been used up. 1 lamp 2 lamps 3 lamps 4 lamps = 25 % = 50 % = 75 % = 100 % The number of operating hours used remains in the memory, even when the appliance is switched off or there is a power cut. 15 Operation Altering the operating hours counter for the grease filters The operating hours counter for the grease filters is set at the factory for 30 hours. This can be lengthened or shortened to suit the type of cooking you do. You can choose 20, 30, 40 or 50 hours. The - / + indicator lamps show the time which has been set: 1st lamp from the left = 20 hours 2nd lamp from the left = 30 hours 3rd lamp from the left = 40 hours 4th lamp from the left = 50 hours ^ Use the - /+ controls to select the desired time. ­ Select a short time if you roast or fry a lot. ­ If you only cook occasionally we recommend that you still select a short time, because grease which has built up gradually over a long period of time will harden on the grease filters and make cleaning more difficult. ^ Press the On/Off control to switch the fan off. ^ Confirm the selection by pressing the grease filter control. If you do not confirm your selection within 4 minutes, the cooker hood will automatically revert to the "old" data. ^ Press the run-on option control and the grease filter control at the same time. The indicator lamp for the grease filter control and one of the - / + indicator lamps will flash. 16 Operation Activating and altering the operating hours counter for the charcoal filter (. . . U models only) The charcoal filter is needed for recirculation mode. On delivery, the operating hours counter for the charcoal filter is deactivated. For recirculation mode, the operating hours counter needs to be set to suit the type of cooking you do: ^ Confirm the selection by pressing the charcoal filter control. If you do not confirm your selection within 4 minutes, the cooker hood will automatically revert to the "old" data. ^ Use the - /+ controls to select the desired time. ^ Press the On/Off control to switch the fan off. Resetting the operating hours counter for the charcoal filter ^ Press the run-on option and the charcoal filter controls at the same time. The indicator lamp for the charcoal filter control and one of the lamps above the - / + controls will flash. The indicator lamp for the charcoal filter control will light up after the cooker hood has operated for the number of hours set. Afterwards, the charcoal filter operating hours counter must be reset. The - /+ control lamps show the time which has been set: 1st lamp from the left = 120 hours 2nd lamp from the left = 180 hours 3rd lamp from the left = 240 hours 4th lamp from the left = deactivated ^ Press and hold the charcoal filter control for about 3 seconds while the fan is switched on. The indicator lamp for the control will go out. 17 Operation Reading the operating hours counter for the charcoal filter To check the percentage of time set already used: ^ Press the On/Off control to switch the fan on. ^ Press and hold the charcoal filter control. One or more of the indicator lamps for the - /+ controls will flash. The number of flashing lamps shows the percentage of the operating time which has already been used up. 1 lamp 2 lamps 3 lamps 4 lamps = 25 % = 50 % = 75 % = 100 % The number of operating hours used remains in the memory, even when the appliance is switched off or there is a power cut. 18 Cleaning and care Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply. Ensure that: - it is switched off at the isolator, or - the fuse from the fused spur connection unit is withdrawn, or - the mains fuse is disconnected, or - the screw-out fuse is removed (in countries where this is applicable). E-Cloth ^ A microfibre "E-Cloth" is available from the Miele UK Spare Parts Department, which is suitable for cleaning surfaces such as stainless steel, glass, plastic and chrome without the use of chemicals. Do not use: ­ cleaning agents containing soda, acids, chlorides or solvents, ­ abrasive cleaning agents e. g. pot scourers or sponges which have been previously used with abrasive cleaning agents. [. . . ] When switched off there must be an all-pole contact gap of 3 mm in the switch (including switch, fuses and relays according to EN 60 335). If the switch is not accessible after installation (depending on country), an additional means of disconnection must be provided for all poles. For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA. Important U. K. , IRL, NZ, ZA: This appliance is supplied for connection to an a. c. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIELE DA 270-4




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIELE DA 270-4 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.