User manual MIDAS CONSOLES XL3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIDAS CONSOLES XL3. We hope that this MIDAS CONSOLES XL3 user guide will be useful to you.


MIDAS CONSOLES XL3 : Download the complete user guide (1909 Ko)

Manual abstract: user guide MIDAS CONSOLES XL3

Detailed instructions for use are in the User's Guide.

[. . . ] The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product. 1 2 3 4 5 6 7 Read these instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. Do not defeat the safety purpose of the polarized or grounding-type plug. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet. 12 Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. [. . . ] Ports that don't have a device allocated to them it will have the text "unused" inside the brackets after their name. For example, choose "Line IO". 3 XL8 Control Centre Quick Reference Guide How to patch 31 In the device ID: drop-down list, click the ID you want for the device. In the device options: drop-down list(s), choose the type of each card fitted in the physical unit. Repeat for any other cards. 4 5 6 Click OK. How to patch Patching, basically, involves selecting the source patching connectors in the From section of the Patching screen and then selecting their destination(s) in the To section. You can select patches singly, or in multiples by using the sequence and automatic operations. >> To open a tab in the From or To sections Click the tab title. >> To select a single patch connector Click the patch connector. The effects of clicking a patch connector are shown in the following table. Table 2: Effects of clicking a patch connector Click To do this in the From section Select the patch the connector ( ). To do this in the To section Will do one of the following (provided a source patch connector(s) has been selected in the From section): · · Select the patch connector ( ) during a single patching operation. Patch the patch connector ( ) during either a sequence or an automatic patching operation. Otherwise, this has no effect. The diagram right shows the two types of gain that can appear in the input gain/trim section at the top of each GUI input fast strip. Adjust the gain trim control knob to set the stage box input gain (2. 5dB steps for the DL431 Mic Splitter and DL443 Analogue Jack I/O Module, and 5dB steps for the DL451 and DL351 Modular I/Os). Adjust level to suit the Midas pre-amp characteristic; a suitable level could be one that only just illuminates the yellow LEDs. Drive the mic amps for that `Midas colouration' -- feel free to overdrive if you want. 3 4 5 6 After you have achieved the required gain state, press the left/right arrowed gain swap button again to swap back to console digital trim. Adjust the gain trim control knob to set the console digital trim (gives +20dB to -40dB continuous trim) for preferred gain structure. Set analogue remotes for initial set-up, then adjust digital trim for showtime. Setting the high and low pass filters When switched in, the high and low pass filters have two settings each, selectable via their respective SLOPE button. >> To set a filter 1 In the gain trim section of an input fast strip (see Figure 11, "Gain and filters sections of the input strips, " on page 33), press the quick access button. This selects the input channel and assigns its configuration detail area to the GUI channel strip (shown above), which contains the filters section. In the filters section of the input channel strip, press the filter select button (high pass or low pass ) to switch the filter in. If necessary press the filter's SLOPE button to set its slope (dB); its status is shown on the GUI. For the high pass filter, in = 24dB and out = 12dB, and for the low pass filter, in = 12dB and out = 6dB. [. . . ] Disconnect the two mains PowerCon® connectors from the PowerCon® sockets on rear of XL8 Control Centre. To unlock them, twist by about 90° (1/4 turn) anti-clockwise. Setting up the ID of the DL4n1 units After connecting up your XL8 network system, you will need to set up the ID of the DL431 Mic Splitter, DL451 Modular I/O and DL471 DSP units (if they don't already have the ID you want). This is done via the control panel of the unit -- the following diagram shows the control panel of a DL451 Modular I/O. Each unit's ID number is shown on its default display. To change the ID number there is no need to switch on the XL8 Control Centre, as the procedure can be carried out offline. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MIDAS CONSOLES XL3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MIDAS CONSOLES XL3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.