If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MIDAS CONSOLES V190 PSU. We hope that this MIDAS CONSOLES V190 PSU user guide will be useful to you.
Manual abstract: user guide MIDAS CONSOLES V190 PSU
Detailed instructions for use are in the User's Guide.
[. . . ] NE PAS OUVRIR
These symbols are internationally accepted symbols that warn of potential hazards with electrical products. The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. [. . . ] Never, under any circumstances, should the power supply be operated without it's safety earth connection. The V190 series power supply should be installed into a 19" rackmount enclosure. If the power supplies are not in a permanent installation, the rackmount enclosure construction should take into account the weight of the supply to prevent damage to either the power supply or enclosure while in transit. Air Flow The V190 power supply has a forced air cooling channel flowing from back to front. To maintain adequate ventilation to the unit, the cooling channel must not be blocked or hindered and one unit (1U) should be left free between the top of the power supply and any other equipment or the rack. The rackmount enclosure should allow adequate airflow to both the front and back panels of the power supply. If using a number of power supplies, one unit (1U) space should be left free above each supply.
0
I
Front
Power Low Mains +48V +12V _ 18V +18V
PUSH
DC Output / Link
RISK OF ELECTRIC SHOCK DO NOT OPEN
CAUTION
CHECK VOLTAGE SELECTOR BEFORE APPLYING MAINS.
DC Output / Link
Pin 1 0VA Pin 2 - + 18V _ Pin 3 18V Pin 4 - + 12V Pin 5 - + 48V Pin 6 0VL Shell - Chassis
PUSH
DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, AVIS: RISQUE DE CHOC ELECTRIQUE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
FIRE REPLACE WITH THE SAME TYPE AND VALUE FUSE INDICATED. COMME INDIQUÉ.
CAUTION: FOR CONTINUED PROTECTION AGAINST RISK OF ATTENTION: REMPLACER PAR UN FUSIBLE DE MÊME TYPE
MADE IN KIDDERMINSTER, ENGLAND
DC Output / Link
Rear
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
100V/120V/220V/240V AC~50-60Hz 520W
SUPPLY VOLTAGE
FUSE: 5x20mm T5A L250V
Interference Some interference may be noticed when the power supply is situated in close proximity to the Verona console. Moving the power supply away from the console will rectify this problem.
Service
The power supply may only be serviced by authorised personnel. Depending upon where the power supply is installed, the interior of the unit will become, over time, dirty and will require cleaning. The power supply should also be serviced if it is dropped, exposed to rain or moisture, liquid has been spilled into the supply or if the unit ceases to function normally.
DO NOT REMOVE THE COVER
The inside of the power supply contains potentially lethal voltages and is capable of providing high currents. To reduce the possibility of electric shock, do not open the cover to the power supply. High voltages are still present in the supply, even when isolated from the mains.
Operators Manual - Page 1
Connection and Operation
Connection
Before powering up the V190 power supply, connect either the front or rear power supply output to the power inlet socket on the console. The V190 power supply provides:
PUSH
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 -
0VA + 18V _ 18V + 12V + 48V 0VL
+12 volts ±18 volts + 48 volts
DC Output / Link
The power supply should only be connected to the console using the provided power connection cable. If, for any reason, the power connection cable should become damaged, the cable should be serviced by an authorised Midas service agent immediately or a Midas authorised replacement sought.
WARNING: The V190 power supply is capable of providing high currents. A short-circuit on any of the voltage supply pins of the power supply or connector will cause a high current to flow from the supply which could lead to damage both to the supply and to connected equipment and also a risk of fire and severe burns to persons. The V190 power supply should be connected to the mains with the supplied IEC mains leads.
220VAC
The V190 is a Linear power supply capable of operation where the nominal mains voltage is 100, 120, 220 or 240 VAC (50-60Hz). The correct mains supply voltage must be selected before applying mains power to the unit. [. . . ] The external power supply can be used on 24-56 channel frame sizes to add redundancy or replace the internal supplies. Two external supplies would be required to replace the internal supplies of the 56 channel console and retain redundancy. The external supply has a "daisy chain" facility (as shown below) allowing for a number of power supplies to be used together adding redundancy to the system in the event of a power supply failing. Connection Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Case 6 Pin Male XLR 0V Analogue +18V Analogue -18V Analogue +12V Gooseneck Light +48V Phantom 0V Gooseneck Light Chassis
Under NO circumstances should the Venice series power supply be used with the Verona. [. . . ]