User manual MICROTEK TMA 1600 INSTALL GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MICROTEK TMA 1600. We hope that this MICROTEK TMA 1600 user guide will be useful to you.


MICROTEK TMA 1600 INSTALL GUIDE: Download the complete user guide (434 Ko)

Manual abstract: user guide MICROTEK TMA 1600INSTALL GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] The unauthorized use of such documents could be a violation of the rights of the copyright holder. Microtek bears no responsibility for the unauthorized use of copyrighted materials. A. Using the 35mm Slide Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Using the 35mm Filmstrip Template . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The side of the template (which reads "Microtek" logo) should face up. For details on how to load the different sizes of film into the template, refer to other sections of this chapter. 3. [Optional] If the black plate* is available, slide it until its edge is against the film. Place the template (side reading "Microtek logo" facing up) on the scanner glass surface. Make sure that the template's front corners are firmly aligned against the top ruler of the scanner, and that the two edges (left and right) fit within the scanner glass area. The Grabber is used for removing the template out of the scanner glass surface. 1 2 3 4 5 6 0 1 2 3 4 5 6 0 6 5 4 3 2 1 0 1 2 3 4 5 6 Please note that the calibration window on the glass surface should be kept clear and free from any obstruction during scanning. 1 2 3 4 5 6 Templates are designed for multiple placement. If you purchase additional templates, simply place templates side by side. For 35mm filmstrip templates, the scanner can scan 7 filmstrips at most (i. e. , the filmstrip nearest the back of the scanner is thus out of the scanning range). 5. Gently lower the TMA1600 down onto the scanner glass surface. Microtek TMA1600 Installing and Getting Started 7 0 1 2 3 4 5 6 A. Using the 35mm Slide Template The 35mm Slide Template can hold up to four mounted slides at a time. During operation, it is recommended that the template be placed on the glass surface first, and the slides loaded into the template next. Place the template (which the side reads "Microtek" logo should face up) on the scanner glass surface. 1 2 3 4 5 6 Make sure that the template's front corners are firmly aligned against the top ruler of the scanner, and that the top edges (left and right) fit within the scanner glass area. 2. Load the film face down inside the frame of template. 0 1 2 3 4 5 1 2 3 4 5 6 0 1 2 3 4 5 6 6 Align the slide against the bottom-left corner of the frame 8 Microtek TMA1600 Installing and Getting Started B. Using the 35mm Filmstrip Template The 35mm Filmstrip Template can hold up to two strips at a time. Slide the film along the slots of the template until its edge is against the side of the template (indicated by an arrow mark ). Align the edge of the film frame with the arrow mark of the template 2. Place the template assembly on the scanner glass surface. 1 2 3 4 5 6 0 1 2 3 4 5 6 Microtek TMA1600 Installing and Getting Started 9 C. Using the 6 x 9 cm Filmstrip Template The 6 x 9 cm Filmstrip Template allows you to scan varying sizes of transparencies, including 6 x 4. 5 cm, 6 x 6 cm, 6 x 7 cm, and 6 x 9 cm. The maximum number of film that can be loaded depends on the size of your film. (e. g. , the 6 x 4. 5 cm can hold up to 4 pieces of film, the 6 x 9 cm can hold up to 2 pieces of film) 1. Slide the film along the slots of the template until its edge is against the side of the template (indicated by an arrow mark ). Align the edge of the film frame with the arrow mark of the template 2. Slide the black plate* until its edge is against the film, thus covering the blank spaces. The side of the black plate (which reads "This side up") should face up. 3. Place the template assembly on the scanner glass surface. 1 2 3 4 5 6 10 Microtek TMA1600 Installing and Getting Started 0 1 2 3 4 5 6 D. [. . . ] In Windows, select the Start menu, Programs, Microtek ScanWizard Pro for Windows, then Microtek Scanner ICC Profiler. Set the appropriate parameters, click the Start Profiling button, then follow the screen instructions to generate your ICC profile. Choose the scanner model you are currently using. Select "Positive" Select the date code and target type to match your target 18 Microtek TMA1600 Installing and Getting Started 4. For details, refer to the help file of your Scanner ICC Profiler program. 5. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MICROTEK TMA 1600




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MICROTEK TMA 1600 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.