User manual MGE PULSAR EVOLUTION 2200

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MGE PULSAR EVOLUTION 2200. We hope that this MGE PULSAR EVOLUTION 2200 user guide will be useful to you.


MGE PULSAR EVOLUTION 2200 : Download the complete user guide (614 Ko)

Manual abstract: user guide MGE PULSAR EVOLUTION 2200

Detailed instructions for use are in the User's Guide.

[. . . ] This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Page 2 - 3400723100/AD Introduction CAUTION: Safety of persons The UPS has its own internal power source (the battery). Consequently, the power outlets may be energized even if the UPS is disconnected from the AC-power source. Measurements are required to ensure that the total leakage current of the UPS and the protected equipment does not exceed 3. 5 mA by checking their characteristics (maximum leakage current of the UPS = 2 mA). [. . . ] 6, 094, 363 AC Output Programmable BATTERY CONNECTOR Volt: 72Vdc 40A AC Output Volt 120V~1O Hertz 50/60 Hz W/VA 1540W/1920VA Volt 120V~1O Amps 16A MAX Hertz 50/60 Hz 360° Rotation Plug 2 Programmable 9 8 1 1 2 29 AC Input 34Z5 U. P. S. R 2 - Connect the protected equipment to the UPS using the rotation power cord 25 . It is advised to connect priority loads to the four standard receptacles 8 and any nonpriority loads to the two programmable receptacles 9 . If the UPS is connected to a computer running MGE communications software, it is possible to program the interruption of power to the programmable receptacles 9 during operation on battery power, thus reserving backup power for the priority loads. Eight hours are required to charge to the full rated backup time. 25 10 3400723100/AD - Page 13 2. Installation 2. 5 Connection to the RS232 or USB communications port (optional) CAUTION: The RS232 and USB communications ports cannot operate simultaneously. 26 1 - Connect the RS232 26 or USB 27 communications cable to the serial port or the USB port on the computer. 27 RS232 2 344-50297-00 1 2 - Connect the other end of the communications cable 26 or 27 to the RS232 2 or USB 1 communications port on the UPS. The UPS can now communicate with all MGE UPS SYSTEMS supervision, set-up or safety software. 2. 6 Connection to the data-line protection port (optional) The data-line protection function on the UPS eliminates overvoltage flowing on the computer-network lines. Simply connect the line to be protected to the UPS using the data-line protection connectors (IN and OUT) as indicated opposite (RJ45 cables not supplied). Data line protection RS232 TO BATTERY CABINET TO BATTERY CABINET SITE WIRING FAULT Data line protection Pb WARNING 3 battery cabinets max for 3000 12 battery cabinets max for 3000XL Only for 3000 72Vdc, 9Ah OUT IN 344-50297-00 SITE WIRING FAULT Pb WARNING 3 battery cabinets max for 3000 12 battery cabinets max for 3000XL Only for 3000 72Vdc, 9Ah OUT IN U. S. 6, 094, 363 BATTERY CONNECTOR Volt: 72Vdc 40A Page 14 - 3400723100/AD 2. Installation 2. 7 Installation of the communications-card option 1 - Remove the slot cover 5 secured by two screws. 2 - Insert the card in the slot. RS232 TO BATTERY CABINET 5 344-50297-00 3 - Secure the cover with the two screws. It is not necessary to shut down the UPS to install the communications card. Slot for the communications-card option. Data line protection SITE WIRING FAULT Pb WARNING 3 battery cabinets max for 3000 12 battery cabinets max for 3000XL Only for 3000 72Vdc, 9Ah OUT IN 3400723100/AD - Page 15 3. The buzzer beeps twice during the self-test, then button 15 remains ON, indicating that the receptacles are supplied with power. The protected equipment is supplied by the UPS, operating on battery power. All the connected equipment is supplied with power. 15 16 17 1 2 % % 1 2 % % Page 16 - 3400723100/AD 3. Operation 3. 3 Operation on battery power (following failure of AC-input power) Transfer to battery power The AC-input power is out of tolerances, LED 16 goes ON. During operation on battery power, the buzzer beeps every ten seconds. The equipment connected to the UPS is supplied by the battery. 16 1 2 % % Threshold for the low-battery warning When the threshold is reached, the buzzer beeps every three seconds. The low-battery warning threshold can be set by the user, with the "UPS Driver" software. [. . . ] Circuit breaker protecting the upstream distribution system against UPS faults. Circuit breaker protecting the UPS against high overloads or faults on the connected equipment. The parameters for a number of UPS functions may be modified using the UPS Driver software to adapt UPS operation to user needs. They may be used for sequential start-up of protected equipment, shedding of non-critical loads during operation on battery power or management of operating priorities to provide the most critical devices with more backup time before battery power runs out. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MGE PULSAR EVOLUTION 2200




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MGE PULSAR EVOLUTION 2200 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.