User manual MEADE 1209 ZERO IMAGE-SHIFT MICROFOCUSER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MEADE 1209 ZERO IMAGE-SHIFT MICROFOCUSER. We hope that this MEADE 1209 ZERO IMAGE-SHIFT MICROFOCUSER user guide will be useful to you.


MEADE 1209 ZERO IMAGE-SHIFT MICROFOCUSER : Download the complete user guide (1188 Ko)

Manual abstract: user guide MEADE 1209 ZERO IMAGE-SHIFT MICROFOCUSER

Detailed instructions for use are in the User's Guide.

[. . . ] The microfocuser maintains precise image centering on even the smallest CCD chips. Important Note: The microfocuser is shipped with the SC accessory adapter (L, Fig. Unthread the adapters from each other before attaching the microfocuser. the adapter (D, Fig. [. . . ] If it becomes necessary to adjust the microfocuser ball bearings (see Fig. (A) Rear cell of telescope (shown separate from the telescope assembly for the sake of clarity); (B) Microfocuser adapter; (C) Microfocuser; (D) 1. 25" accessory adapter. SC accessory adapter (L) may be used in this position instead if Schmidt-Cassegrain accessories are being used. Do not use either adapter if using a 2" diagonal diagonal mirror; (E) Eyepiece holder thumbscrew; (F) Eyepiece; (G) 1. 25 "Diagonal Prism. 2" diagonal mirror may also be used in this position (12" models); (H) Adapter thumbscrew; (I) Microfocuser thumbscrews; (J) Microfocuser bearings; (K) Set screws. Groove Line up Fig. 3b: Line up SC adapter groove with microfocuser thumbscrew. adjusted, performance will degrade and damage will result. Damage due to improper adjustments not authorized by the factory will not be covered under warranty. Note: If you wish to mount a camera directly to the microfocuser, you need to attach an optional TAdapter to the microfocuser. For more information about Meade optional accessories, see the Meade General Catalog or contact your local Meade dealer. Perform this step of the procedure during the daytime, without the eyepiece assembly (eyepiece, diagonal, etc. ) attached to the microfocuser. When the drawtube reaches the furthest extension of its travel, listen for a change in the pitch of the motor. Notice that the drawtube's maximum extension is about a half-inch out from the microfocuser. Set the drawtube so that it extends about a quarter-inch (about halfway). When you begin your viewing session, attach your telescope's eyepiece assembly. 6) to change the speed: Each press of the Speed key decreases the focus speed until the lowest speed is reached. You may need to repeat steps 2 through 5 when you change eyepieces. Fig. [. . . ] Using the provided hex key, tighten to a firm feel one of the three microfocuser set screws (K, Fig. Take care not to tighten or loosen the adapter ring as you position and tighten the microfocuser in place. 6: Microfocuser handbox: (1) In/Out keys; (2) Speed key; (3) Handbox port (on top) 12:00 position Fig. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MEADE 1209 ZERO IMAGE-SHIFT MICROFOCUSER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MEADE 1209 ZERO IMAGE-SHIFT MICROFOCUSER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.