User manual MAYTAG HVP41250PCGA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAYTAG HVP41250PCGA. We hope that this MAYTAG HVP41250PCGA user guide will be useful to you.


MAYTAG HVP41250PCGA : Download the complete user guide (805 Ko)

Manual abstract: user guide MAYTAG HVP41250PCGA

Detailed instructions for use are in the User's Guide.

[. . . ] Series Twelve POWER VENT GAS WATER HEATER USER'S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES Model Numbers HVN41240PCGA HVN41250PCGA HVN41250VCGA HVP41240PCGA HVP41250PCGA HVP41250VCGA CANADIAN MANUAL · · · · · · Safety Instructions Installation Operation Care and Maintenance Troubleshooting Parts List C3 Technology® Gas Water Heaters meet the new ANSI Z21. 10. 1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. PRINTED IN THE U. S. A. 185380-000 SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. [. . . ] If any of these conditions are found, they must be corrected in accordance with the venting instructions in this manual before completing the installation and putting the water heater into service. Except where instructed in this manual, the mixing of 2", 3" and 4" vent pipe is NOT ALLOWED. If 2" pipe is to be used, then a 2" to 3" bell reducer is recommended. If the bell reducer is located at the rubber boot on the blower assembly, then a short section of 3" vent pipe needs to be installed in the rubber boot for proper connection of the 2" to 3" bell reducer. If 4" pipe is to be used, then a 3" to 4" bell reducer is recommended. If the bell reducer is located at the rubber boot on the blower assembly, then a short section of 3" vent pipe needs to be installed in the rubber boot for proper connection of the 3" to 4" bell reducer. The water heaters covered by this manual are supplied with a 2" Schedule 40 PVC 22. 5° Vent Terminal. If you decide to vent with 3" or 4" pipe, a Schedule 40 DWV 45° Vent Terminal must be used. For your convenience, we have included a screen for both 3" and 4" Vent Terminals. The vent piping should be connected to the blower with a rubber adapter and secured with hose clamps. Even though the flue gas temperature leaving the blower is between 140°F (69°C) and 175°F (79°C), some installations will have water vapor condense in the vent piping. If this occurs, then adequate means of draining and disposing of the condensate needs to be made by the installer. 18 CONDENSATION Condensate formation does not occur in all installations of power vented water heaters, but should be protected against on installations where it can form in the venting system. Condensation in the venting system of power vented water heaters is dependent upon installation conditions including, but not limited to ambient temperature and humidity of installation location, ambient temperature and humidity of venting space, vent discharge and slope, and product usage. In certain conditions, installations in unconditioned space or having long horizontal or vertical vent runs may accumulate condensate. In these conditions, the vent pipe should be sloped downward away from the blower assembly 1/4" (6. 4 mm) per five feet (1. 5 m) of pipe but not more than 1 1/2" (3. 8 cm) in the total vent length. If the vent piping is vented level or sloped upwards away from the blower assembly, then adequate means for draining and disposing of the condensate needs to be made by the installer (if condensate is detected). If you have condensate, then a 3/8" drain hose can be connected to the built-in drain port of the rubber boot on the blower assembly. For your convenience, the rubber boot is supplied with a removable cap on the built-in drain port. Prior to operating the water heater, make sure the removable cap is installed on the drain port (if a drain hose is not needed). MAXIMUM VENT LENGTHS 40, 000 BTU Units: For 2" Venting, the maximum equivalent feet of pipe allowed is 40 feet (12. 2 m). This does not include the supplied vent termination for the water heater. For the 2" venting, one 90° elbow is approximately equal to 5 feet (1. 5 m). It is recommended that at least 2 feet (0. 6 m) of spacing be used in between all 45° elbows and all 90°elbows. [. . . ] Check that the ground conductor on the water heater is properly connected. Replace gas control valve. ABC Wiring error or a high resistance to earth ground. ABC Pressure switch remained closed longer than 5 seconds after the call for heat began. Pressure switch remained open longer than 5 seconds after the combustion blower was energized. System in lockout. ABC ABC ABC WATER HEATER CONTROL ABC Problem in the gas valve driver circuit. ABC Problem with the internal circuit. ABC Problem with the internal circuit. ABC ABC Flame signal sensed out of proper sequence. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HVP41250PCGA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAYTAG HVP41250PCGA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.