User manual MAYTAG HVP41250P

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAYTAG HVP41250P. We hope that this MAYTAG HVP41250P user guide will be useful to you.


MAYTAG HVP41250P : Download the complete user guide (807 Ko)

Manual abstract: user guide MAYTAG HVP41250P

Detailed instructions for use are in the User's Guide.

[. . . ] Series Twelve POWER VENT GAS WATER HEATER USER'S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES Model Numbers HVN41240P HVN41250P HVN41250V HVP41240P HVP41250P HVP41250V · · · · · · Safety Instructions Installation Operation Care and Maintenance Troubleshooting Parts List C3 Technology® Gas Water Heaters meet the new ANSI Z21. 10. 1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. PRINTED IN THE U. S. A. 185378-001 SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. [. . . ] · For Schedule 40, 3" PVC, ABS, Coex Cellular Core vent pipe: Every 3. 5 feet (1. 1 m). · For Schedule 40, 4" PVC, ABS, Coex Cellular Core vent pipe: Every 4 feet (1. 2 m). · For Schedule 40, 2" CPVC vent pipe: Every 5 feet (1. 5 m). · For Schedule 40, 3" CPVC vent pipe: Every 6 feet (1. 8 m). · For Schedule 40, 4" CPVC vent pipe: Every 6. 5 feet (2. 0 m). It is imperative that the first hanger (or support) be located on the horizontal run immediately adjacent to the first 90-degree elbow from the vertical rise. Support method used should isolate the vent pipe from the floor joists or other structural members to prevent the transmission of noise and vibration. Do not support, pin, or otherwise secure the venting system in a way that restricts the normal thermal expansion and contraction of the chosen venting material. If the water heater is being installed as a replacement for an existing power vented heater in pre-existing venting, a thorough inspection of the existing venting system must be performed prior to any installation work. Verify that the correct material as detailed above has been used, and that the minimum or maximum vent lengths and terminal location as detailed in this manual have been met. Carefully inspect the entire venting system for any signs of cracks or fractures, particularly at the joints between elbows and other fittings and the straight runs of vent pipe. Check the system for signs of sagging or other stresses in the joints as a result of misalignment of any components in the system. If any of these conditions are found, they must be corrected in accordance with the venting instructions in this manual before completing the installation and putting the water heater into service. Except where instructed in this manual, the mixing of 2", 3" and 4" vent pipe is NOT ALLOWED. If 2" pipe is to be used, then a 2" to 3" bell reducer is recommended. If the bell reducer is located at the rubber boot on the blower assembly, then a short section of 3" vent pipe needs to be installed in the rubber boot for proper connection of the 2" to 3" bell reducer. If 4" pipe is to be used, then a 3" to 4" bell reducer is recommended. If the bell reducer is located at the rubber boot on the blower assembly, then a short section of 3" vent pipe needs to be installed in the rubber boot for proper connection of the 3" to 4" bell reducer. The water heaters covered by this manual are supplied with a 2" Schedule 40 PVC 22. 5° Vent Terminal. If you decide to vent with 3" or 4" pipe, a Schedule 40 DWV 45° Vent Terminal must be used. For your convenience, we have included a screen for both 3" and 4" Vent Terminals. The vent piping should be connected to the blower with a rubber adapter and secured with hose clamps. [. . . ] Check that the ground conductor on the water heater is properly connected. Replace gas control valve. ABC Wiring error or a high resistance to earth ground. ABC Pressure switch remained closed longer than 5 seconds after the call for heat began. Pressure switch remained open longer than 5 seconds after the combustion blower was energized. System in lockout. ABC ABC ABC WATER HEATER CONTROL ABC Problem in the gas valve driver circuit. ABC Problem with the internal circuit. ABC Problem with the internal circuit. ABC ABC Flame signal sensed out of proper sequence. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HVP41250P




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAYTAG HVP41250P will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.