User manual MAYTAG HRX50YART

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAYTAG HRX50YART. We hope that this MAYTAG HRX50YART user guide will be useful to you.


MAYTAG HRX50YART : Download the complete user guide (708 Ko)

Manual abstract: user guide MAYTAG HRX50YART

Detailed instructions for use are in the User's Guide.

[. . . ] Series Ten GAS WATER HEATER USER'S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES C3 Technology® Gas Water Heaters meet the new ANSI Z21. 10. 1 standard that deals with the accidental or unintended ignition of flammable vapors, such as those emitted by gasoline. Model Numbers HRX40YARS HRX40HARS HRX40YART HRX40HART HRX40YQRT HRX40HQRT HRX50YART HRX50HART HRX50YQRT5 HRX50HQRT5 HRX50YQRT HRX50HQRT For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. PRINTED IN THE U. S. A 0405 1 PART NO. 184388-002 66001907 SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. [. . . ] To prevent bodily injury, hazard to life, or property damage, the relief valve must be allowed to discharge water in quantities should circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage. The Discharge Pipe: · Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. · Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, and the discharge pipe. · Shall not have any valve between the relief valve and tank. The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot. If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater, follow the draining instructions, and replace the temperature-pressure relief valve with a new one. Filling the Water Heater FIGURE 17. Never use this water heater unless it is completely full of water. Water must flow from the hot water faucet before turning "ON" gas to the water heater. To fill the water heater with water: · Close the water heater drain valve by turning the handle to 15 the right (clockwise). NOTE: The cold water supply valve must be left open when the water heater is in use. · To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Repair as needed. Specialist at 1-800-365-0024 or gas supplier to aid you in determining the proper venting for your water heater from the vent tables in the current edition of the National Fuel Gas Code ANSI Z223. 1/NFPA 54. Periodically check the venting system for signs of obstruction or deterioration and replace if needed. The water heater with draft hood installed must be connected to a chimney or listed vent pipe system, which terminates to the outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation. · For proper draft hood attachment, the draft hood legs may be angled slightly inward. · Place the draft hood legs in the receiving holes on the top of the water heater. With the vent pipe in position, drill a small hole through both the vent pipe and draft hood. Obstructed or deteriorated vent systems may present serious health risk or asphyxiation. Venting VENT DAMPERS - Any vent damper, whether it is operated thermally or otherwise must be removed if its use inhibits proper drafting of the water heater. Thermally Operated Vent Dampers: Gas-fired water heaters having thermal efficiency in excess of 80% may produce a relatively low flue gas temperature. Such temperatures may not be high enough to properly open thermally operated vent dampers. This would cause spillage of the flue gases and may cause carbon monoxide poisoning. Vent dampers must bear evidence of certification as complying with the current edition of the American National Standard ANSI Z21. 68 (ANSI Z21. 66 & 67, respectively, cover electrically and mechanically actuated vent dampers). [. . . ] Poor combustion. PILOT WILL NOT LIGHT PILOT OUTAGE NOT ENOUGH HOT WATER WATER TOO HOT WATER HEATER SOUNDS SIZZLING - RUMBLING SOOTING VENT GAS ODORS 26 REPAIR PARTS LIST MAYTAG GAS WATER HEATERS MODEL NO'S HRX40YARS HRX40HARS HRX40YART HRX40HART HRX40YQRT HRX40HQRT 40 40 40 40 40 40 Gallon Natural Gas Gallon Propane Gas (L. P. ) Gallon Natural Gas Gallon Propane Gas (L. P. ) Gallon Natural Gas Gallon Propane Gas (L. P. ) BURNER ASSEMBLY PILOT ASSEMBLY Key No. 1 2 3 3 4 5 5 6 7 8 9 10 11 12 13 14 15 16 *17 18 19 20 21 22 22 23 24 25 26 27 28 Part Description Air Intake Screen Anode Rod Burner Assembly - Std. Burner Assembly - High Altitude Burner Head** Burner Orifice - Std. ** Burner Orifice - High Altitude** Burner Tube** Dip Tube/Inlet Tube Dip Tube/Inlet Tube Gasket Draft Hood Drain Valve Drain Valve Washer Flue Baffle Flue Restrictor Gas Control Valve Inner Door** Inner Door Gasket Instruction Manual Nipple w/Heat Traps Outer Door Outer Door Filler Piezo Igniter w/Bracket Pilot Assembly - Std. ** Pilot Assembly - High Altitude** Pipe Insulation Secondary Anode Rod T & P Insulation Temperature-Pressure Relief Valve Thermostat Shield (Optional) Viewport Assembly Includes Inner Door Gasket HRX40YARS 9003406 9001834 9003379 9003489 9003385 9003493 9003492 9003389 9003500 9001595 9003405 9002402 9001584 9003480 9000275 9003407 9003398 9003401 184388-002 9003719 9003409 NA 9003410 9003530 9003542 9003971 9004274 9003716 9000071 9003696 9003414 HRX40HARS 9003406 9001834 9003554 9003584 9003631 9003453 9003453 9003476 9003500 9001595 9003405 9002402 9001584 9003480 9000275 9003408 9003398 9003401 184388-002 9003719 9003409 NA 9003410 9003455 9003455 9003971 9004274 9003716 9000071 9003696 9003414 Model Numbers HRX40YART 9003406 9001834 9003563 9003596 9003385 9003453 9003453 9003391 9003501 9001595 9003405 9002402 9001584 9003649 9000275 9003407 9003400 9003401 184388-002 9003719 9003409 NA 9003410 9003530 9003542 9003971 9004274 9003716 9000071 9003696 9003414 HRX40HART 9003406 9001834 9003564 9003597 9003422 9003453 9003453 9003392 9003501 9001595 9003405 9002402 9001584 9003649 9000275 9003408 9003400 9003401 184388-002 9003719 9003409 NA 9003410 9003472 9003472 9003971 9004274 9003716 9000071 9003696 9003414 HRX40YQRT 9003406 9003487 9003549 9003578 9003421 9003494 9003494 9003635 9003637 9001595 9003499 9002401 9001584 9003636 9003524 9003638 9003400 9003401 184388-002 NA 9003409 NA 9003410 9003530 9003542 9003971 NA 9003716 9004030 9003696 9003414 HRX40HQRT 9003406 9003487 9003550 9003579 9003633 9003643 9003647 9003644 9003637 9001595 9003499 9002401 9001584 9003636 9003524 9003639 9003400 9003401 184388-002 NA 9003409 NA 9003410 9003543 9003543 9003971 NA 9003716 9004030 9003696 9003414 * Not Shown. ** Now that you have purchased this gas water heater, should a need ever exist for repair parts or service, simply call a Maytag Service Specialist at 1-800-365-0024 for an authorized servicer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HRX50YART




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAYTAG HRX50YART will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.