User manual MAYTAG HRP11250P

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAYTAG HRP11250P. We hope that this MAYTAG HRP11250P user guide will be useful to you.


MAYTAG HRP11250P : Download the complete user guide (931 Ko)

Manual abstract: user guide MAYTAG HRP11250P

Detailed instructions for use are in the User's Guide.

[. . . ] Series Twelve POWER VENT GAS WATER HEATER USER'S GUIDE FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MANUFACTURED (MOBILE) HOMES Model Numbers HRN11240P HRN31240P HRP11240P HRP31240P HRN11250P HRN31250P HRP11250P HRP31250P HRN11275P HRN31275P HRP11275P HRP31275P For Your Safety AN ODORANT IS ADDED TO THE GAS USED BY THIS WATER HEATER. PRINTED IN THE U. S. A. 66001897 184683-001 SAFE INSTALLATION, USE AND SERVICE Your safety and the safety of others is extremely important in the installation, use and servicing of this water heater. Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety messages and instructions throughout this manual. [. . . ] If more are required the venting distance must be reduced 5 feet for every 90o elbow. LENGTH (FT. ) 70 65 60 55 50 45 NUMBER OF 90o ELBOWS* 1 2 3 4 5 6 FIGURE 40. · Minimum vent length for all 40, 000 BTU/HR input models is 4 feet and 16 inches for all other models. VENTING THROUGH AN OUTSIDE WALL WITH LOW GROUND CLEARANCE · When the venting piping cannot pass through an outside wall at a height greater than or equal to 12" above the ground (or above snow accumulation level), then the installation can be modified as shown below. 75 GALLON 70, 000 AND 75, 000 BTU/HR MODELS ONLY OPTIONAL 4" VENT PIPING 4" DIA. LENGTH (FT. ) 110 105 100 95 90 85 NUMBER OF 90o ELBOWS* 1 2 3 4 5 6 ALL 40 AND 50 GALLON 40, 000 BTH/HR MODELS ONLY 3" DIA. LENGTH (FT. ) 115 110 105 100 95 90 NUMBER OF 90o ELBOWS* 1 2 3 4 5 6 ALL 40 AND 50 GALLON 40, 000 BTH/HR MODELS ONLY OPTIONAL 2" VENT PIPING 2" DIA. LENGTH (FT. ) 50 45 40 35 30 25 NUMBER OF 90o ELBOWS* 1 2 3 4 5 6 FIGURE 41. * Two 45o elbows are equivalent to one 90o elbow. 22 · Refer to the tables on page 23 for maximum vent lengths for low ground clearance installations. All installations assume the use of two additional 90 elbows and the standard 45o vent cap with screen outside of the exterior wall. 75 GALLON 70, 000 AND 75, 000 BTU/HR MODELS ONLY 3" DIA. LENGTH (FT. ) 60 55 50 45 40 35 NUMBER OF 90 ELBOWS*(Inside bldg. ) 1 2 3 4 5 6 Primer, cleaner and cements are extremely flammable. The vapors are harmful They may irritate eyes and skin and can be absorbed through the skin. Always store primers, cleaners and cements in cool, dry, well ventilated places. If swallowed, drink water, do not induce vomiting, and call a physician or poison control center immediately. If inhaled, get fresh air and seek medical attention if ill feeling persists. In case of eye and skin contact, immediately flush with plenty of water for 15 minutes and seek medical attention if irritation persists. All primers, cleaners and cements must meet all local codes and applicable standards of the American Society for Testing Materials Standards. Before using primers, cleaners and cements, stir or shake, making sure contents of liquid. Cut pipe ends squarely removing all burrs and dirt. 75 GALLON 70, 000 AND 75, 000 BTU/HR MODELS ONLY OPTIONAL 4" VENT PIPING 4" DIA. LENGTH (FT. ) 100 95 90 85 80 75 NUMBER OF 90o ELBOWS*(Inside bldg. ) 1 2 3 4 5 6 ALL 40 AND 50 GALLON 40, 000 BTU/HR MODELS 3" DIA. LENGTH (FT. ) 105 100 95 90 85 80 NUMBER OF 90o ELBOWS*(Inside bldg. ) 1 2 3 4 5 6 2. Push pipe completely into socket of fitting, turning as it goes until it bottoms. APPROXIMATE SETTING TIME FOR 2 1/2" TO 4" PIPE JOINTS MOVEMENT OF JOINTS 3/4 HR. 18 HRS. ALL 40 AND 50 GALLON 40, 000 BTU/HR MODELS OPTIONAL 2" VENT PIPING 2" DIA. [. . . ] Thermal expansion in closed water system. LEAKING T & P HOT WATER ODORS (Refer to Smelly Water) WATER TOO HOT WATER HEATER SOUNDS SIZZLING-RUMBLING SOOTING HEATER LIGHTS BUT GOES OUT IN 4-5 SECONDS Improperly seated valve. Outlet polarity is reversed. 40 REPAIR PARTS LIST MAYTAG GAS WATER HEATERS MODEL NO'S HRN11240P HRN31240P HRP11240P HRP31240P 40 40 40 40 Gallon Natural Gas Gallon Natural Gas Gallon Propane Gas (L. P. ) Gallon Propane Gas (L. P. ) PCV, ABS OR CPVC ITEMS FOR ALL MODELS SUPPLIED LOCALLY Key No. 1 2 3 *4 5 6 7 8 9 10 11 12 13 14 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 *31 Part Description Temperature-Pressure Relief Valve Primary Anode Rod Drain Valve Drain Valve Washer (17/32" x 13/64" x 1/8" thick) Secondary Anode Rod w/Heat traps Pressure Switch Power Cord On/Off Switch Burner Orifice (Drill Size) Manifold Burner Outer Door Inner Door Gas Control Valve (Natural) Gas Control Valve (Propane{L. P. ]) Dip Tube Flue Baffle Junction Box Cover Inlet Nipple w/Heat Traps Pipe Insulation (2 ea. ) Wiring Harness T & P Insulation Water Heater Stand Blower/ Draft Hood Ass'y Venting Switch 3" or 2" Schedule 40 90 o Elbow 3" or 2" Schedule 40 Vent Pipe Wall Collar 3" PVC Vent Terminal Hot Surface Ignition Ass'y Mounting Bracket Manual HRN11240P 66001700 66001020 66001015 66001021 66001881 66001369 66001372 66001247 66001538 66001530 66001027 66001190 66001029 66001527 -------66001617 66001399 66001895 66001707 66001755 66001526 66001709 66001243 66001366 66001367 ---------------66001262 66001255 66001525 66001896 66001897 Model Numbers HRN31240P 66001700 66001020 66001015 66001021 66001881 66001369 66001372 66001247 66001538 66001530 66001027 66001190 66001029 66001527 -------66001617 66001399 66001895 66001707 66001755 66001526 66001709 66001243 66001366 66001367 --------------66001262 66001255 66001525 66001896 66001897 HRP11240P 66001700 66001020 66001015 66001021 66001881 66001369 66001372 66001247 66001538 66001533 66001027 66001190 66001029 -------66001528 66001617 66001399 66001895 66001707 66001755 66001526 66001709 66001243 66001366 66001367 --------------66001262 66001255 66001525 66001896 66001897 HRP31240P 66001700 66001020 66001015 66001021 66001881 66001369 66001372 66001247 66001538 66001533 66001027 66001190 66001029 -------66001528 66001617 66001399 66001895 66001707 66001755 66001526 66001709 66001243 66001366 66001367 --------------66001262 66001255 66001525 66001896 66001897 * Not Shown. Now that you have purchased this gas water heater, should a need ever exist for repair parts or service, simply call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HRP11250P




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAYTAG HRP11250P will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.