User manual MAYTAG HRE2940T

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAYTAG HRE2940T. We hope that this MAYTAG HRE2940T user guide will be useful to you.


MAYTAG HRE2940T : Download the complete user guide (1241 Ko)

Manual abstract: user guide MAYTAG HRE2940T

Detailed instructions for use are in the User's Guide.

[. . . ] Series Nine ELECTRIC WATER HEATER USER'S GUIDE Model Numbers HRE2930T HRE3930T HRE2940L HRE3940L HRE2940S HRE3940S HRE2940T HRE3940T HRE2950S HRE3950S HRE2950T HRE3950T HRE2966T HRE3966T FOR POTABLE WATER HEATING ONLY GAMA certification applies to all residential electric water heaters with capacities of 20 to 120 Gallons. Input rating of 12 Kw or less at a voltage no greater than 250 V. NOT SUITABLE FOR SPACE HEATING Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. Part No. 66001711 184741-000 WARNING READ THE GENERAL SAFETY SECTION BEGINNING ON INSIDE COVER AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS WATER HEATER. 0104 Safety Instructions WARNING Improper installation, adjustment, alteration, service or maintenance can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. [. . . ] NOTE: If you have purchased a three wire connection water heater but you are not on a "Time Clock" or "Off Peak" meter and have a standard two wire connection power supply, simply follow the connection diagram in block 3 of the Three Wire Connection Diagram. Use wire nuts and connect the power supply wiring to the wires inside the water heater's junction. The water heater must be electrically "grounded" by the installer. A green ground screw has been provided on the water heater's junction box. Replace the wiring junction cover using the screw provided. WARNING WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: This water heater is equipped for one type voltage only. Check the rating plate near the bottom access panel for the correct voltage. DO NOT use this water heater with any voltage other than the one shown on the model rating plate. Failure to use the correct voltage can cause problems which can result in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. If you have any questions or doubts consult your electric company. CAUTION If wiring from your fuse box or circuit breaker box was aluminum for your old water heater, replace it with copper wire. If you wish to reuse the existing aluminum wire, have the connection at the water heater made by a competent electrician. Call Maytag Customer Service at 1-800-788-8899 for an authorized servicer. Provide a way to easily shut off the electric power when working on the water heater. This could be with a circuit breaker or fuse block in the entrance box or a separate disconnect switch. Install and connect a circuit directly from the main fuse or circuit breaker box. This circuit must be the right size and have its own fuse or circuit breaker. Refer to the chart in the "Product Specifications" section for the correct size wire and fuse or circuit breaker. The grounding electrode conductor shall be of copper, aluminum, or copperclad aluminum. The material shall be of one continuous length without a splice or joint. Rigid metal conduit, intermediate metal conduit, or electrical metallic tubing may be used for the grounding means if conduit or tubing is terminated in fittings approved for grounding. WIRE NUTS CONDUIT 17 GREEN GROUND SCREW Instructions for Installation (cont'd) Installation Checklist 1. Whether or not the element conversion is made, the model rating plate must be marked. Using a hard point ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel. Is the fuse or circuit breaker size correct as shown in the chart in the "Product Specifications" section? CONDUIT HOT COLD HOT COLD 3. [. . . ] WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: Model Number Serial Number Part Description Part Number THIS IS A REPAIR PARTS LIST, NOT A PACKING LIST. 31 Repair Parts List (cont'd) MAYTAG ELECTRIC WATER HEATERS MODEL NUMBERS HRE2950S 50 GALLON HRE3950S 50 GALLON HRE2950T 50 GALLON HRE3950T 50 GALLON HRE2966T 66 GALLON HRE3966T 66 GALLON NOTE: UPPER ELEMENT: These water heaters are equipped with 3800 watt elements. LOWER ELEMENT: These water heaters are equipped with factory installed convertible elements, which can be operated at 3800 watts or 5500 watts. If a replacement 3800 watt, 240 volt element is needed, order part no. If, at the time of installation, the water heater was converted to operate at 5500 watts, order part number 66001107 replacement element. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAYTAG HRE2940T




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAYTAG HRE2940T will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.