User manual MAXTOR TM6701AN

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXTOR TM6701AN. We hope that this MAXTOR TM6701AN user guide will be useful to you.


MAXTOR TM6701AN : Download the complete user guide (96 Ko)

Manual abstract: user guide MAXTOR TM6701AN

Detailed instructions for use are in the User's Guide.

[. . . ] Application Note: PULNIX TM-6701AN Camera Descriptions Interfacing non-standard cameras to Matrox Pulsar February 4, 1998 Interface Modes Camera Interface Briefs 640 x 480 x 8-bit @ 60fps or 640 x 240 x 8-bit @ 120fps · Analog video output. Continuous (60 MHz, 120 MHz), internal reset (fast, slow) · Mode 1 : Continuous (60 Hz) PULNiX TM 6701AN · · · · · Video Matrox Pulsar 640 x 480 x 8-bit @ 60fps Analog (composite) video output. [. . . ] The shutter control switch on the rear of the camera must be set to position `0'. · Camera's Rear Panel Mode 3 and 4: Internal fast and slow reset · Positions 1 through 8 of the shutter control switch on the rear of the camera correspond to the following exposure times: Shutter control switch positions Internal fast reset mode Position Exposure time (s) 1 1/320001H 2 1/160002H 3 1/8000 4H 4 1/4000 8H Internal slow reset mode Position Exposure time (s) 5 1/200016H 6 1/100032H 7 1/500 64H 8 1/250128H · · · The delay between the rising edge of the external trigger pulse and the falling edge of the TTL_EXPOSURE1 pulse is 10µs. The width of the TTL_EXPOSURE1 pulse must be greater than 63µs (two horizontal line times). The camera is reset upon the falling edge of the TTL_EXPOSURE1 (VINIT IN) pulse and will expose for the amount of time as set on the shutter control switch. . Mode 5 and 6 : Asynchronous reset (Pulse Width Control - 60 and 120 Hz) · The three switches on the rear of the camera must be set respectively to ASY (asynchronous shutter mode), N and O for 60 Hz operation, and ASY, N, and T for 120 Hz operation; the shutter control switch on the rear of the camera must be set to position 9. The camera is reset upon the falling edge of the EXPOSURE1 (VINIT IN) pulse. The exposure period is for the inactive (low) period of EXPOSURE1 (VINIT IN). The default exposure time in this DCF is 6. 4 ms. · PUL-CID-050 3 Application Note: PULNIX TM-6701AN Cabling Requirements Interfacing non-standard cameras to Matrox Pulsar February 4, 1998 Mode 1 and 2: Continuous (60 and 120 Hz) · · IMG-7W2-TO-1BNC cable required for video input of camera (single input) Video input of IMG-7W2-TO-1BNC cable should be connected to video out BNC connector of camera Mode 1: Internal fast reset mode Mode 3: Internal slow reset · · · · IMG-7W2-TO-5BNC cable and PLS-TTL-CABLE required video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT BNC connector of camera the three switches on the rear of the camera must be set respectively to ASY (asynchronous shutter mode), N and O; the shutter control switch on the rear of the camera must be set to a position between 1 and 4 the connections between the DB-37 connector of the PLS-TTL-CABLE, the 12-pin connector of the camera and the power supply are as follows: PLS-TTL-CABLE (DB-37 connector) Pin name Pin no. TTL_EXPOSURE1 9 GROUND 7 PULNiX TM-6701AN (12-pin connector) Pin name Pin no. VINIT in 6 GND 1, 3, 5, or 8 12V DC in 2 POWER SUPPLY GND +12V · TTL external trigger source should be connected to the TTL Trigger Input of the IMG-7W2TO-5BNC cable. Mode 4: Internal slow reset · · · · · IMG-7W2-TO-5BNC cable and PLS-TTL-CABLE required video input BNC of IMG-7W2-TO-5BNC cable should be connected to VIDEO OUT BNC connector of camera the three switches on the rear of the camera must be set respectively to ASY (asynchronous shutter mode), N and T; the shutter control switch on the rear of the camera must be set to a position between 5 and 8 the connections between the DB-37 connector of the PLS-TTL-CABLE and the 12-pin connector of the camera are as in internal fast reset mode. TTL external trigger source should be connected to the TTL Trigger Input of the IMG-7W2TO-5BNC cable PUL-CID-050 4 Application Note: PULNIX TM-6701AN Cabling Requirements (continued) Interfacing non-standard cameras to Matrox Pulsar February 4, 1998 Mode 5 and 6 : Asynchronous reset (Pulse Width Control - 60 and 120 Hz) · · · · IMG-7W2-TO-5BNC cable and PLS-TTL-CABLE required Video input BNC of IMG-7W2-TO-5BNC cable should be connected to video out BNC connector of camera The connections between the DB-37 connector of the PLS-TTL-CABLE and the 12-pin connector of the camera are as in internal fast reset mode. [. . . ] SL2 4JS Tel: +44 (0) 1753 665500 Fax: +44 (0) 1753 665599 France Matrox France SARL 2, rue de la Couture, Silic 225 94528 Rungis Cedex Tel: (0) 1 45-60-62-00 Fax: (0) 1 45-60-62-05 Germany Matrox GmbH Inselkammerstr. 8 D-82008 Unterhaching Germany Tel: 089/614 4740 Fax: 089/614 9743 Asia Pacific Matrox Asia Liaison Office Rm. 1901, 19/F, Workington Tower, 78 Bonham Strand E. , Sheung Wan, Hong Kong. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR TM6701AN




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR TM6701AN will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.