User manual MAXTOR MEDALIST 630XE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXTOR MEDALIST 630XE. We hope that this MAXTOR MEDALIST 630XE user guide will be useful to you.


MAXTOR MEDALIST 630XE : Download the complete user guide (210 Ko)

You may also download the following manuals related to this product:

   MAXTOR MEDALIST 630XE QUICK GUIDE (113 ko)
   MAXTOR MEDALIST 630XE INSTALLATION (113 ko)

Manual abstract: user guide MAXTOR MEDALIST 630XE

Detailed instructions for use are in the User's Guide.

[. . . ] . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Medalist 630xe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ATA Interface Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Medalist 630xe . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ATA Interface Drive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . © 1996 Seagate Technology, Inc. A, June 1996 Supersedes Publication Number 36330-xxx Seagate, Seagate Technology and the Seagate logo are registered trademarks of Seagate Technology, Inc. [. . . ] For the mating connector, use a 40-pin, nonshielded connector with 2 rows of 20 female contacts. We recommend the following part numbers: AMP Berg Electronics 499496 66900-040 Dimensions are in inches 0. 100 ± 0. 010 0. 70 ± 0. 010 0. 235 ± 0. 025 0. 230 ± 0. 003 0. 025 ± 0. 002 0. 025 ± 0. 002 0. 160 1. 90 2. 00 0. 100 typ 0. 070 ± 0. 010 Figure 3. The drive interface connector 2. 3 Power connector The drive comes with a standard 4-pin power connector. 2. 4 Master/slave jumper block The master/slave jumper block allows you to configure the drive for operation. Figure 4 on page 18 shows the master/slave jumper block configuration options. A spare jumper is attached in a neutral position on pins 1 and 3 by the factory. If you need additional jumpers, use Seagate part number 10562-001 or an equivalent. If you use a jumper that is not the correct size, you may damage the jumper block and the jumper. 18 Medalist 630xe and 850xe ATA Product Manual, June 1996 1357 2468 Spare jumper 1357 Single drive or Master with an ATA-compatible slave The drive is the slave Master with a non-ATA-compatible slave Cable select 2468 Figure 4. Master/slave jumper block settings 2. 4. 1 Single-drive or master with an ATA-compatible slave This is the factory default configuration (the jumper place on pins 1 and 3 is a spare and does not affect drive operation). The drive operates as a single drive on the controller or as the master drive with an ATA-compatible slave. 2. 4. 2 The drive as slave To make the drive the slave, attach the jumper to pins 7 and 8. 2. 4. 3 Master with a non-ATA-compatible slave This setting allows you to configure the drive to work with some slaves that do not conform to the DASP­ timing parameter of the ATA specification. When a jumper is placed on pins 5 and 6, the drive assumes a slave is present and ignores the initial DASP­ signal. The slave must return the PDIAGS­ signal. 2. 4. 4 Cable-select configuration To configure the drive for computers that use cable select (CSEL), place the jumper on pins 3 and 4. The interface cable must be designed for cable-select interconnection. The cable construction determines whether the drive is the master or the slave. Medalist 630xe and 850xe ATA Product Manual, June 1996 19 Slave CSEL not carried to pin 28 of this connector Master Pin 28 grounded at computer Computer Figure 5. Connecting cable-selected drives 2. 4. 5 Factory-test configuration Do not install jumpers on pins 5 and 6 and pins 7 and 8 at the same time. When jumpers are installed in both of these positions, the heads continuously seek back and forth across the media and the drive ignores all control signals sent through the interface. 2. 5 Mounting the drive You can mount the drive in any orientation using either the bottom or the side mounting holes as described below. Insert four mounting screws not more than 0. 20 inches (6 full turns) into the drive frame. Insert four mounting screws not more than 0. 13 inches (4 full turns) into the drive frame. To prevent damage to the drive: · Use only mounting screws of the correct size and length. · Lightly tighten the mounting screws--do not apply more than 6 inch-pounds of torque. 20 Medalist 630xe and 850xe ATA Product Manual, June 1996 Figure 6 shows the dimensions in inches. 0. 15 ± 0. 01 Six #6-32 UNC-2B mounting holes 1. 000 max 2. 362 ± 0. 010 4. 000 ± 0. 010 0. 630 ± 0. 025 0. 250 ± 0. 010 0. 030 5. 77 max 2. 375 ± 0. 025 1. 75 ± 0. 010 3. 750± 0. 030 Four #6-32 UNC-2B mounting holes Figure 6. Standard mounting dimensions 4. 02 max Medalist 630xe and 850xe ATA Product Manual, June 1996 21 3. 0 ATA interface The drives use an ATA interface. The interface is in compliance with ANSI ATA (AT Attachment) Interface X3. 221, Rev. 2. 0; SFF 8019: Identify Drive Data for Drives Under 8 GB and Draft Proposal American National Standards AT Attachment Interface X3. 310-948D, Rev. [. . . ] The host should retry the transfer as individual requests to obtain valid error information. Subsequent blocks or partial blocks are transferred only if the error was a correctable data error. All other errors cause the command to stop after the block containing the error is transferred. 3. 3. 6 Write Multiple command (C5H) The Write Multiple command (C5H) is similar to the Write Sectors command. However, instead of generating interrupts to transfer each sector, interrupts are generated to transfer blocks of sectors as defined by the Set Multiple Mode command. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR MEDALIST 630XE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR MEDALIST 630XE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.