User manual MAXTOR DIAMONDMAX 21 REV C 8-2007

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXTOR DIAMONDMAX 21. We hope that this MAXTOR DIAMONDMAX 21 user guide will be useful to you.


MAXTOR DIAMONDMAX 21 REV C 8-2007: Download the complete user guide (1038 Ko)

Manual abstract: user guide MAXTOR DIAMONDMAX 21REV C 8-2007

Detailed instructions for use are in the User's Guide.

[. . . ] Product Manual DiamondMax 21 STM3500630AS STM3320620AS STM3320820AS STM3250824AS STM3250820AS STM3250310AS STM3160815AS STM3160215AS STM380815AS STM380215AS STM340215AS 100451230 Rev. C August 2007 Revision status summary sheet Revision Date Sheets Affected Rev. 1, 3-5, 8-10, 16-21, 24-26, 29, 39 and 41. Copyright © 2006, 2007 Seagate Technology LLC. C August 2007 Seagate, Seagate Technology and the Wave logo are registered trademarks of Seagate Technology LLC in the United States and/or other countries. [. . . ] C 2. 9 2. 9. 1 Environmental specifications Ambient temperature Ambient temperature is defined as the temperature of the environment immediately surrounding the drive. Actual drive case temperature should not exceed 69°C (156°F) within the operating ambient conditions. Above 1, 000 feet (305 meters), the maximum temperature is derated linearly to 112°F (44°C) at 10, 000 feet (3, 048 meters). Operating: Nonoperating: 0° to 60°C (32° to 140°F) ­40° to 70°C (­40° to 158°F) 2. 9. 2 Operating: Temperature gradient 20°C per hour (68°F per hour max), without condensation 30°C per hour (86°F per hour max) Nonoperating: 2. 9. 3 2. 9. 3. 1 Operating: Humidity Relative humidity 5% to 90% noncondensing (30% per hour max) 5% to 95% noncondensing (30% per hour max) Nonoperating: 2. 9. 3. 2 Operating: Wet bulb temperature All models STM3500630AS, STM3320620AS, STM3320820AS, STM3250824AS, STM3250820AS, STM3250310AS STM3250824AS, STM3160815AS, STM3160215AS, STM380815AS, STM380215AS and STM340215AS 37. 7°C (99. 9°F max) 37. 7°C (99. 9°F max) 40°C (104°F max) Nonoperating: 2. 9. 4 Operating: Altitude ­60. 96 m to 3, 048 m (­200 ft. to 40, 000+ ft. ) Nonoperating: 2. 9. 5 Shock All shock specifications assume that the drive is mounted securely with the input shock applied at the drive mounting screws. 2. 9. 5. 1 Operating shock STM3500630AS, STM3320620AS, STM3320820AS, STM3250820AS, STM3160815AS, STM3160215AS, STM380815AS, STM380215AS and STM340215AS These drives comply with the performance levels specified in this document when subjected to a maximum operating shock of 68 Gs based on half-sine shock pulses of 2 msec. Shocks should not be repeated more than two times per second. DiamondMax 21 Serial ATA Product Manual, Rev. C 23 STM3250824AS and STM3250310AS These drives comply with the performance levels specified in this document when subjected to a maximum operating shock of 63 Gs based on half-sine shock pulses of 2 msec. 2. 9. 5. 2 Nonoperating shock STM3320620AS, STM3320820AS, STM3250824AS, STM3250820AS, STM3250310AS, STM3160815AS, STM3160215AS, STM380815AS, STM380215AS and STM340215AS The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 350 Gs based on a nonrepetitive half-sine shock pulse of 2 msec duration. STM3500630AS The nonoperating shock level that the drive can experience without incurring physical damage or degradation in performance when subsequently put into operation is 300 Gs based on a nonrepetitive half-sine shock pulse of 2 msec duration. 2. 9. 6 Vibration All vibration specifications assume that the drive is mounted securely with the input vibration applied at the drive mounting screws. 2. 9. 6. 1 Operating vibration The maximum vibration levels that the drive may experience while meeting the performance standards specified in this document are specified below. 5­22 Hz 22­350 Hz 350­500 Hz 0. 25 Gs (Limited displacement) 0. 50 Gs 0. 25 Gs 2. 9. 6. 2 Nonoperating vibration The maximum nonoperating vibration levels that the drive may experience without incurring physical damage or degradation in performance when subsequently put into operation are specified below. 5­22 Hz 22­350 Hz 350­500 Hz 0. 25 Gs (limited displacement) 5. 0 Gs 1. 0 Gs 24 DiamondMax 21 Serial ATA Product Manual, Rev. C 2. 10 Acoustics Drive acoustics are measured as overall A-weighted acoustic sound power levels (no pure tones). Sound power measurements are taken under essentially free-field conditions over a reflecting plane. The number of seeks per second is defined by the following equation: (Number of seeks per second = 0. 4 / (average latency + average access time) Table 8: Fluid Dynamic Bearing (FDB) motor acoustics Idle* Seek 3. 7 bels (typ)** 3. 9 bels (max)** 3. 0 bels (typ)** 3. 2 bels (max)** 3. 4 bels (typ)** 3. 6 bels (max)** 2. 7 bels (typ)*** 2. 8 bels (max)*** 3. 0 bels (typ)*** 3. 2 bels (max)*** STM3500630AS STM3320620AS, STM3320820AS, and STM3250820AS STM3250824AS STM3250310AS STM3160815AS, STM3160215AS, STM380815AS STM380215AS and STM340215AS 2. 8 bels (typ) 3. 0 bels (max) 2. 5 bels (typ) 2. 9 bels (max) 2. 7 bels (typ) 2. 9 bels (max) 2. 6 bels (typ) 2. 7 bels (max) 2. 8 bels (typ) 3. 0 bels (max) *During periods of drive idle, some offline activity may occur according to the S. M. A. R. T. specification, which may increase acoustic and power to operational levels. ***Measured in quiet mode. 2. 11 Electromagnetic immunity When properly installed in a representative host system, the drive operates without errors or degradation in performance when subjected to the radio frequency (RF) environments defined in the following table: Table 9: Test Electrostatic discharge Radiated RF immunity Electrical fast transient Surge immunity Conducted RF immunity Voltage dips, interrupts Radio frequency environments Description Contact, HCP, VCP: ± 4 kV; Air: ± 8 kV 80 to 1, 000 MHz, 3 V/m, 80% AM with 1 kHz sine 900 MHz, 3 V/m, 50% pulse modulation @ 200 Hz ± 1 kV on AC mains, ± 0. 5 kV on external I/O ± 1 kV differential, ± 2 kV common, AC mains Performance level B A Reference standard EN 61000-4-2: 95 EN 61000-4-3: 96 ENV 50204: 95 EN 61000-4-4: 95 EN 61000-4-5: 95 EN 61000-4-6: 97 EN 61000-4-11: 94 B B 150 kHz to 80 MHz, 3 Vrms, 80% AM with 1 kHz sine A 0% open, 5 seconds 0% short, 5 seconds 40%, 0. 10 seconds 70%, 0. 01 seconds C C C B DiamondMax 21 Serial ATA Product Manual, Rev. C 25 2. 12 2. 12. 1 Reliability Annualized Failure Rate (AFR) and Mean Time Between Failures (MTBF) The product shall achieve an Annualized Failure Rate (AFR) of 0. 34% (MTBF of 0. 7 million hours) when operated in an environment of ambient air temperatures of 25°C. Operation at temperatures outside the specifications in Section 2. 9 may increase the product AFR (decrease MTBF). AFR and MTBF are population statistics that are not relevant to individual units. AFR and MTBF specifications are based on the following assumptions for desktop personal computer environments: · 2400 power-on-hours per year. · Temperatures outside the specifications in Section 2. 9 may reduce the product reliability. Operation at excessive I/O duty cycle may degrade product reliability. The desktop personal computer environment of power-on-hours, temperature, and I/O duty cycle affect the product AFR and MTBF. [. . . ] C 39 Note. See the bit descriptions below for words 63, 88, and 93 of the Identify Drive data. Description (if bit is set to 1) Bit 0 1 2 8 9 10 Bit 0 1 2 3 4 5 6 8 9 10 11 12 13 14 Word 63 Multiword DMA mode 0 is supported. Ultra DMA mode 6 is currently active. 40 DiamondMax 21 Serial ATA Product Manual, Rev. C 4. 3. 2 Set Features command This command controls the implementation of various features that the drive supports. When the drive receives this command, it sets BSY, checks the contents of the Features register, clears BSY and generates an interrupt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR DIAMONDMAX 21




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR DIAMONDMAX 21 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.