User manual MAXTOR CHEETAH 15K.4 FC

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXTOR CHEETAH 15K.4 FC. We hope that this MAXTOR CHEETAH 15K.4 FC user guide will be useful to you.


MAXTOR CHEETAH 15K.4 FC : Download the complete user guide (2666 Ko)

You may also download the following manuals related to this product:

   MAXTOR CHEETAH 15K.4 FC INSTALLATION (444 ko)

Manual abstract: user guide MAXTOR CHEETAH 15K.4 FC

Detailed instructions for use are in the User's Guide.

[. . . ] Cheetah 15K. 4 FC ST3146854FC ST373454FC ST336754FC Cheetah 15K. 4 FC ST3146854FC ST373454FC ST336754FC ©2004, 2005 Seagate Technology LLC All rights reserved Publication number: 100220449, Rev. C May 2005 Seagate, Seagate Technology, and the Seagate logo are registered trademarks of Seagate Technology LLC. SeaTools, SeaFONE, SeaBOARD, and SeaTDD are either registered trademarks or trademarks of Seagate Technology LLC. Other product names are registered trademarks or trademarks of their owners. [. . . ] input/output operations per second 6. 4 Environmental limits Temperature and humidity values experienced by the drive must be such that condensation does not occur on any drive part. Altitude and atmospheric pressure specifications are referenced to a standard day at 58. 7°F (14. 8°C). Operating The maximum allowable continuous or sustained HDA case temperature for the rated MTBF is 122°F (50°C) The maximum allowable HDA case temperature is 60°C. Occasional excursions of HDA case temperatures above 122°F (50°C) or below 41°F (5°C) may occur without impact to specified MTBF. Continual or sustained operation at HDA case temperatures outside these limits may degrade MTBF. Provided the HDA case temperatures limits are met, the drive meets all specifications over a 41°F to 131°F (5°C to 55°C) drive ambient temperature range with a maximum temperature gradient of 36°F (20°C) per hour. Air flow may be needed in the drive enclosure to keep within this range (see Section 8. 3). Operation at HDA case temperatures outside this range may adversely affect the drives ability to meet specifications. To confirm that the required cooling for the electronics and HDA case is provided, place the drive in its final mechanical configuration, perform random write/read operations and measure the HDA case temperature after it has stabilized. 32 Cheetah 15K. 4 FC Product Manual, Rev. Non-operating ­40° to 158°F (­40° to 70°C) package ambient with a maximum gradient of 36°F (20°C) per hour. This specification assumes that the drive is packaged in the shipping container designed by Seagate for use with drive. HDA Temp. Check Point 1. 0 " . 5" Figure 11. Locations of the HDA temperature check point 6. 4. 2 Relative humidity The values below assume that no condensation on the drive occurs. Operating 5% to 95% non-condensing relative humidity with a maximum gradient of 20% per hour. Non-operating ­1, 000 to +40, 000 feet (­305 to +12, 210 meters) 6. 4. 4 Shock and vibration Shock and vibration limits specified in this document are measured directly on the drive chassis. If the drive is installed in an enclosure to which the stated shock and/or vibration criteria is applied, resonances may occur internally to the enclosure resulting in drive movement in excess of the stated limits. If this situation is apparent, it may be necessary to modify the enclosure to minimize drive movement. The limits of shock and vibration defined within this document are specified with the drive mounted by any of the four methods shown in Figure 12, and in accordance with the restrictions of Section 8. 5. Operating--normal The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding 15 Gs at a maximum duration of 11 msec (half sinewave). The drive, as installed for normal operation, shall operate error free while subjected to intermittent shock not exceeding 65 Gs at a maximum duration of 2 msec (half sinewave). Shock may be applied in the X, Y, or Z axis. Cheetah 15K. 4 FC Product Manual, Rev. Operating--abnormal Equipment, as installed for normal operation, does not incur physical damage while subjected to intermittent shock not exceeding 40 Gs at a maximum duration of 11 msec (half sinewave). Shock occurring at abnormal levels may promote degraded operational performance during the abnormal shock period. [. . . ] If your location is not listed here, dial our presales and technical support call center at +1-405324-4714 from 8:00 A. M. The presales and technical support call center is located in Oklahoma City, USA. For European warranty service, dial the toll-free number for your specific location. If your location is not listed here, dial our European CSO warranty center at +31-20-316-7222 from 8:30 A. M. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE MAXTOR CHEETAH 15K.4 FC




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual MAXTOR CHEETAH 15K.4 FC will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.